Impact of Source Conditions on Collision Cross Section Determination by Trapped Ion Mobility Spectrometry

被引:0
|
作者
George, Anais C. [1 ]
Schmitz, Isabelle [1 ]
Colsch, Benoit [2 ]
Afonso, Carlos [1 ]
Fenaille, Francois [2 ]
Loutelier-Bourhis, Corinne [1 ]
机构
[1] Normandie Univ, Univ Rouen Normandie, INSA Rouen Normandie, CNRS,COBRAUMR 6014,INC3M FR 3038, F-76000 Rouen, France
[2] Univ Paris Saclay, CEA, INRAE, Dept Med & Technol Sante DMTS,MetaboHUB, F-91191 Gif sur Yvette, France
关键词
Lipids; Solvent-ion cluster; Collisioncross section; Ion mobility-mass spectrometry; Trappedion mobility spectrometry; STRUCTURAL-CHARACTERIZATION; GAS MODIFIERS; METABOLOMICS; VALUES;
D O I
10.1021/jasms.3c00361
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Collision cross section (CCS) values determined in ion mobility-mass spectrometry (IM-MS) are increasingly employed as additional descriptors in metabolomics studies. CCS values must therefore be reproducible and the causes of deviations must be carefully known and controlled. Here, we analyzed lipid standards by trapped ion mobility spectrometry-mass spectrometry (TIMS-MS) to evaluate the effects of solvent and flow rate in flow injection analysis (FIA), as well as electrospray source parameters including nebulizer gas pressure, drying gas flow rate, and temperature, on the ion mobility and CCS values. The stability of ion mobility experiments was studied over 10 h, which established the need for a delay-time of 20 min to stabilize source parameters (mostly pressure and temperature). Modifications of electrospray source parameters induced shifts of ion mobility peaks and even the occurrence of an additional peak in the ion mobility spectra. This behavior could be essentially explained by ion-solvent cluster formation. Changes in source parameters were also found to impact CCS value measurements, resulting in deviations up to 0.8%. However, internal calibration with the Tune Mix calibrant reduced the CCS deviations to 0.1%. Thus, optimization of source parameters is essential to achieve a good desolvation of lipid ions and avoid misinterpretation of peaks in ion mobility spectra due to solvent effects. This work highlights the importance of internal calibration to ensure interoperable CCS values, usable in metabolomics annotation. [GRAPHICS]
引用
收藏
页码:696 / 704
页数:9
相关论文
共 50 条
  • [21] Collision Cross Section Conformational Analyses of Bile Acids via Ion Mobility-Mass Spectrometry
    Poland, James C.
    Leaptrot, Katrina L.
    Sherrod, Stacy D.
    Flynn, Charles Robb
    McLean, John A.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2020, 31 (08) : 1625 - 1631
  • [22] Uncertainty Estimations for Collision Cross Section Determination via Uniform Field Drift Tube-Ion Mobility-Mass Spectrometry
    Causon, Tim J.
    Hann, Stephan
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2020, 31 (10) : 2102 - 2110
  • [23] Fundamentals of Trapped Ion Mobility Spectrometry
    Michelmann, Karsten
    Silveira, Joshua A.
    Ridgeway, Mark E.
    Park, Melvin A.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2015, 26 (01) : 14 - 24
  • [24] Gated trapped ion mobility spectrometry
    Ridgeway, Mark
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 257
  • [25] Tandem trapped ion mobility spectrometry
    Liu, Fanny C.
    Ridgeway, Mark E.
    Park, Melvin A.
    Bleiholder, Christian
    ANALYST, 2018, 143 (10) : 2249 - 2258
  • [26] Coupling trapped ion mobility spectrometry to mass spectrometry: trapped ion mobility spectrometry-time-of-flight mass spectrometry versus trapped ion mobility spectrometry-Fourier transform ion cyclotron resonance mass spectrometry
    Tose, Lilian V.
    Benigni, Paolo
    Leyva, Dennys
    Sundberg, Abigail
    Ramirez, Cesar E.
    Ridgeway, Mark E.
    Park, Melvin A.
    Romao, Wanderson
    Jaffe, Rudolf
    Fernandez-Lima, Francisco
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2018, 32 (15) : 1287 - 1295
  • [27] The IMSCal approach to determine collision cross section of multiply charged anions in traveling wave ion mobility spectrometry
    Sergent, Isaure
    Adjieufack, Abel Idrice
    Gaudel-Siri, Anouk
    Siri, Didier
    Charles, Laurence
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2023, 492
  • [28] Concentration-dependent coulombic effects in travelling wave ion mobility spectrometry collision cross section calibration
    Eldrid, Charles
    O'Connor, Eloise
    Thalassinos, Konstantinos
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2020, 34
  • [29] Sequence-Specific Model for Predicting Peptide Collision Cross Section Values in Proteomic Ion Mobility Spectrometry
    Chang, Chih-Hsiang
    Yeung, Darien
    Spicer, Victor
    Ogata, Kosuke
    Krokhin, Oleg
    Ishihama, Yasushi
    JOURNAL OF PROTEOME RESEARCH, 2021, 20 (07) : 3600 - 3610
  • [30] Determining Collision Cross Sections from Differential Ion Mobility Spectrometry
    Ieritano, Christian
    Lee, Arthur
    Crouse, Jeff
    Bowman, Zack
    Mashmoushi, Nour
    Crossley, Paige M.
    Friebe, Benjamin P.
    Campbell, J. Larry
    Hopkins, W. Scott
    ANALYTICAL CHEMISTRY, 2021, 93 (25) : 8937 - 8944