Role of Multidetector Computed Tomography in the Evaluation of Maxillofacial Trauma

被引:4
|
作者
Reddy, Buchipudi Sandeep [1 ]
Naik, Deepti [1 ]
Kenkere, Deepika [2 ]
机构
[1] Sri Devaraj Urs Acad Higher Educ & Res, Radiodiag, Kolar, India
[2] Sri Devaraj Urs Acad Higher Educ & Res, Oral & Maxillofacial Surg, Kolar, India
关键词
fractures of nasal bone; mandibular bone fracture; maxillo-facial trauma; dental radiology; dentistry; sagittal; coronal; axial; multislice computed tomography; maxillo-facial fractures; INJURIES;
D O I
10.7759/cureus.35008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Maxillofacial fractures are among the commonest injuries occurring in trauma patients. Multislice computed tomography (CT) is a widely used radiological investigation that accurately reveals the number, location, and extent of the fractures as well as concomitant soft tissue injuries and has been found to be superior in the diagnosis of maxillofacial fractures owing to high sensitivity and specificity. This study was performed to assess the efficacy of axial, coronal, sagittal, and three-dimensional (3D) reformatted images in the detection of fractures in maxillofacial trauma.Materials and Methods: This was a cross-sectional descriptive study conducted on 49 adult patients with maxillofacial injuries undergoing multislice CT using a multidetector Siemens SOMATOM Emotion eco 16 slice CT scanner (Siemens AG, Munich, Germany). CT protocol consisted of non-contrast axial 16-slice helical series beam collimation -3 mm, pitch -0.8 -1, tube current -270 mAs, voltage -130 kV, Total exposure time -18 seconds, total radiation -200 mGy. Along with the axial, coronal and sagittal images were reconstructed with 0.5 mm increment. 3D volume-rendering images were also obtained. 3D images were compared with axial images, coronal and sagittal plane images.Results: The maximum number of cases was in the age group of 21-30 years with the male: female ratio being 5.12:1. The most common cause of injury was road traffic accidents (RTA). Mandible fractures were found to be the most common (20 patients, 40.8%) followed by fractures of nasal bone (18 patients, 36.7%). The incidence of frontal bone fractures was found to be the least (six patients, 12.24%). Our study found that 3D images are superior to axial in assessing the extent and degree of displacement of maxillofacial fractures in general. The maxillary sinus was found to be the most commonly fractured sinus (19 patients, 38.7%). Sphenoid sinus fractures were the least common (seen in two patients, 4.08%). CT findings correlated with the operative findings in most types of fractures. Conclusion: Multidetector CT with multiplanar and 3D reformation is highly accurate in the identification of fractures and assessing the extent and degree of displacement of fractures; hence, it is the imaging modality of choice in maxillofacial trauma. 3D images are much better for the detection of maxillofacial fractures compared to axial, coronal, or sagittal views, especially in maxilla and mandibular bone fractures. It is also found to be better at providing information on the patterns of the fracture lines and the displacement of the fracture fragments. Another added advantage of multidetector CT is that it is a non-invasive technique with good accuracy and a short scan time.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Pancreatic Tuberculosis: Role of Multidetector Computed Tomography
    Ibrahim, Gehan Fawzy
    Al-Nakshabandi, Nizar A.
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2011, 62 (04): : 260 - 264
  • [32] Evaluation of Colorectal Cancer by Multidetector Computed Tomography
    Motta Ramirez, Gaspar Alberto
    Alonso Blancas, Erika
    Lozano Dubernard, Gilberto
    Urbina de la Vega, Jose Felipe
    Valenzuela Tamariz, Jorge
    GACETA MEXICANA DE ONCOLOGIA, 2011, 10 (05): : 252 - 264
  • [33] Morphological evaluation of the coccyx with multidetector computed tomography
    Azad Hekimoglu
    Onur Ergun
    Surgical and Radiologic Anatomy, 2019, 41 : 1519 - 1524
  • [34] Multidetector computed tomography evaluation of bladder lesions
    Yoon, Jin Woo
    Park, Sung Bin
    Lee, Eun Sun
    Park, Hyun Jeong
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2023, 54 (01):
  • [35] Evaluation of coronary arteries by multidetector computed tomography
    Duran, Cihan
    Gulbaran, Murat
    Kantarci, Mecit
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2006, 34 (08): : 515 - 526
  • [36] Evaluation of Myocardial Bridge With Multidetector Computed Tomography
    Kim, So Yeon
    Lee, Young Soo
    Lee, Jin Bae
    Ryu, Jae Kean
    Choi, Ji Yong
    Chang, Sung Gug
    Kim, Kee-Sik
    CIRCULATION JOURNAL, 2010, 74 (01) : 137 - 141
  • [37] Morphological evaluation of the coccyx with multidetector computed tomography
    Hekimoglu, Azad
    Ergun, Onur
    SURGICAL AND RADIOLOGIC ANATOMY, 2019, 41 (12) : 1519 - 1524
  • [38] Multidetector computed tomography evaluation of bladder lesions
    Jin Woo Yoon
    Sung Bin Park
    Eun Sun Lee
    Hyun Jeong Park
    Egyptian Journal of Radiology and Nuclear Medicine, 54
  • [39] Multidetector-row computed tomography imaging of splenic trauma
    Marmery, Helen
    Shanmuganathan, K.
    SEMINARS IN ULTRASOUND CT AND MRI, 2006, 27 (05) : 404 - 419
  • [40] Multidetector computed tomography of iatrogenic urinary trauma pictorial review
    Padovan, Ranka S.
    Hrabak, Maja
    Prutki, Maja
    Kralik, Marko
    Lusic, Mario
    Pasini, Josip
    Potocki, Kristina
    CURRENT MEDICAL IMAGING REVIEWS, 2007, 3 (04) : 277 - 282