Role of Multidetector Computed Tomography in the Evaluation of Maxillofacial Trauma

被引:4
|
作者
Reddy, Buchipudi Sandeep [1 ]
Naik, Deepti [1 ]
Kenkere, Deepika [2 ]
机构
[1] Sri Devaraj Urs Acad Higher Educ & Res, Radiodiag, Kolar, India
[2] Sri Devaraj Urs Acad Higher Educ & Res, Oral & Maxillofacial Surg, Kolar, India
关键词
fractures of nasal bone; mandibular bone fracture; maxillo-facial trauma; dental radiology; dentistry; sagittal; coronal; axial; multislice computed tomography; maxillo-facial fractures; INJURIES;
D O I
10.7759/cureus.35008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Maxillofacial fractures are among the commonest injuries occurring in trauma patients. Multislice computed tomography (CT) is a widely used radiological investigation that accurately reveals the number, location, and extent of the fractures as well as concomitant soft tissue injuries and has been found to be superior in the diagnosis of maxillofacial fractures owing to high sensitivity and specificity. This study was performed to assess the efficacy of axial, coronal, sagittal, and three-dimensional (3D) reformatted images in the detection of fractures in maxillofacial trauma.Materials and Methods: This was a cross-sectional descriptive study conducted on 49 adult patients with maxillofacial injuries undergoing multislice CT using a multidetector Siemens SOMATOM Emotion eco 16 slice CT scanner (Siemens AG, Munich, Germany). CT protocol consisted of non-contrast axial 16-slice helical series beam collimation -3 mm, pitch -0.8 -1, tube current -270 mAs, voltage -130 kV, Total exposure time -18 seconds, total radiation -200 mGy. Along with the axial, coronal and sagittal images were reconstructed with 0.5 mm increment. 3D volume-rendering images were also obtained. 3D images were compared with axial images, coronal and sagittal plane images.Results: The maximum number of cases was in the age group of 21-30 years with the male: female ratio being 5.12:1. The most common cause of injury was road traffic accidents (RTA). Mandible fractures were found to be the most common (20 patients, 40.8%) followed by fractures of nasal bone (18 patients, 36.7%). The incidence of frontal bone fractures was found to be the least (six patients, 12.24%). Our study found that 3D images are superior to axial in assessing the extent and degree of displacement of maxillofacial fractures in general. The maxillary sinus was found to be the most commonly fractured sinus (19 patients, 38.7%). Sphenoid sinus fractures were the least common (seen in two patients, 4.08%). CT findings correlated with the operative findings in most types of fractures. Conclusion: Multidetector CT with multiplanar and 3D reformation is highly accurate in the identification of fractures and assessing the extent and degree of displacement of fractures; hence, it is the imaging modality of choice in maxillofacial trauma. 3D images are much better for the detection of maxillofacial fractures compared to axial, coronal, or sagittal views, especially in maxilla and mandibular bone fractures. It is also found to be better at providing information on the patterns of the fracture lines and the displacement of the fracture fragments. Another added advantage of multidetector CT is that it is a non-invasive technique with good accuracy and a short scan time.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Role of multidetector computed tomography in evaluation of resectability of pancreatic cancer
    Azzaz, Hossam Elsayed Mohammed
    Abdullah, Mohamed Shawky
    Habib, Rehab Mohammed
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2021, 52 (01):
  • [22] Multidetector computed tomography in the evaluation of cirsoid aneurysm of the scalp-a manifestation of trauma
    Saade, Charbel
    Wilkinson, Mark
    Parker, Geoff
    Dubenec, Steve
    Brennan, Patrick
    CLINICAL IMAGING, 2013, 37 (03) : 558 - 560
  • [23] THE ROLE OF 3-DIMENSIONAL COMPUTED-TOMOGRAPHY IN THE MANAGEMENT OF MAXILLOFACIAL TRAUMA
    MAYER, JS
    WAINWRIGHT, DJ
    YEAKLEY, JW
    LEE, KF
    HARRIS, JH
    KULKARNI, M
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1988, 28 (07): : 1043 - 1053
  • [24] Multidetector computed tomography in the diagnosis and management of renal trauma
    Sica, G.
    Bocchini, G.
    Guida, F.
    Tanga, M.
    Guaglione, M.
    Scaglione, M.
    RADIOLOGIA MEDICA, 2010, 115 (06): : 936 - 949
  • [25] Multidetector Computed Tomography of Spinal Trauma: A Pictorial Review
    Srinivasan, K.
    Gadodia, Ankur
    Kumar, Atin
    Gamangatti, Shivanand
    CURRENT PROBLEMS IN DIAGNOSTIC RADIOLOGY, 2011, 40 (05) : 181 - 190
  • [26] Multidetector-row computed tomography of thoracic trauma
    Kaewlai, R.
    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2011, 65 : 3 - 16
  • [27] Re: Bladder Trauma: Multidetector Computed Tomography Cystography
    Siegel, Cary
    JOURNAL OF UROLOGY, 2012, 188 (03): : 867 - 867
  • [28] Role of Multidetector Computed Tomography Urography in the Evaluation of Obstructive Uropathy: A Review
    Khandelwal, Shreya
    Dhande, Rajasbala
    Sood, Anshul
    Parihar, Pratapsingh
    Mishra, Gaurav V.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (10)
  • [29] Blunt trauma of bone structures of the chest computed tomography vs multidetector computed tomography
    Petrovic, Kosta
    Turkalj, Ivan
    Stojanovic, Sanja
    Vucaj-Cirilovic, Viktorija
    Nikolic, Olivera
    Stojiljkovic, Dragana
    VOJNOSANITETSKI PREGLED, 2013, 70 (08) : 757 - 761
  • [30] THE ROLE OF COMPUTED-TOMOGRAPHY IN THE EVALUATION OF SPINE TRAUMA
    JEVTIC, V
    TABOR, L
    ZDRAVSTVENI VESTNIK, 1984, 53 (11): : 587 - 599