Biomechanical Effects of Facet Joint Violation After Single-Level Lumbar Fusion With Transpedicular Screw and Rod Instrumentation

被引:2
|
作者
Wangsawatwong, Piyanat [1 ]
Pereira, Bernardo de Andrada [1 ]
Lehrman, Jennifer N. [1 ]
Sawa, Anna G. U. [1 ]
O'Neill, Luke K. [1 ]
Turner, Jay D. [1 ]
Uribe, Juan S. [1 ]
Kelly, Brian P. [1 ,2 ]
机构
[1] St Josephs Hosp, Barrow Neurol Inst, Dept Neurosurg, Phoenix, AZ USA
[2] St Josephs Hosp, Barrow Neurol Inst, Neurosci Publicat, 350 W Thomas Rd, Phoenix, AZ 85013 USA
关键词
adjacent-level degeneration; digital imaging correlation; facet violation; intervertebral disc strain; hypermobility; lumbar biomechanics; lumbar fusion; maximum strain; minimum strain; pedicle screw fixation; principal strains; FIXATION;
D O I
10.1097/BRS.0000000000004698
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design.In vitro biomechanical study. Objective.This study aimed to investigate the biomechanical effects of facet joint violation (FV) on mobility and optically tracked intervertebral disc (IVD) surface strains at the upper level adjacent to L4-5 pedicle screw-rod fixation. Summary of Background Data.FV is a complication that can occur when placing lumbar pedicle screws; the reported incidence is as high as 50%. However, little is known about how FV affects superior adjacent-level spinal stability, and especially IVD strain, after lumbar fusion. Methods.Fourteen cadaveric L3-S1 specimens underwent L4-5 pedicle-rod fixation, 7 in the facet joint preservation (FP) group and 7 in the FV group. Specimens were tested multidirectionally under pure moment loading (7.5 Nm). Colored maps of maximum (& epsilon;1) and minimum (& epsilon;2) principal surface strain changes on the lateral L3-4 disc were generated, with the surface divided into 4 quarters anterior to posterior (Q1, Q2, Q3, and Q4, respectively) for subregional analyses. Range of motion (ROM) and IVD strain were normalized to intact upper adjacent-level and compared between the groups using analysis of variance. Statistical significance was set at PResults.Normalized ROM was significantly greater with FV vs. FP in flexion (11% greater; P=0.04), right lateral bending (16% greater; P=0.03), and right axial rotation (23% greater; P=0.04). Normalized L3-4 IVD & epsilon;1 during right lateral bending was greater on average for the FV group than the FP group: Q1, 18% greater; Q2, 12% greater; Q3, 40% greater (P<0.001); Q4, 9% greater. Normalized & epsilon;2 values during left axial rotation were greater in the FV group, the highest increase being 25% in Q3 (P=0.02). Conclusions.Facet joint violation during single-level pedicle screw-rod fixation was associated with increased superior adjacent level mobility and alteration of disc surface strains, with significant increases in selected regions and directions of loading.
引用
收藏
页码:1033 / 1040
页数:8
相关论文
共 50 条
  • [1] Technical factors related to the incidence of adjacent superior segment facet joint violation after transpedicular instrumentation in the lumbar spine
    Zhiming Chen
    Jie Zhao
    Hao Xu
    Aigang Liu
    Jiandong Yuan
    Cong Wang
    [J]. European Spine Journal, 2008, 17 : 1476 - 1480
  • [2] Technical factors related to the incidence of adjacent superior segment facet joint violation after transpedicular instrumentation in the lumbar spine
    Chen, Zhiming
    Zhao, Jie
    Xu, Hao
    Liu, Aigang
    Yuan, Jiandong
    Wang, Cong
    [J]. EUROPEAN SPINE JOURNAL, 2008, 17 (11) : 1476 - 1480
  • [3] Radiologic evaluation of adjacent superior segment facet joint violation following transpedicular instrumentation of the lumbar spine
    Shah, RR
    Mohammed, S
    Saifuddin, A
    Taylor, BA
    [J]. SPINE, 2003, 28 (03) : 272 - 275
  • [4] The Relationship between Adjacent Segment Pathology and Facet Joint Violation by Pedicle Screw after Posterior Lumbar Instrumentation Surgery
    Oh, Ho-Seok
    Seo, Hyoung-Yeon
    [J]. JOURNAL OF CLINICAL MEDICINE, 2021, 10 (13)
  • [5] TRANSLAMINAR FACET JOINT SCREW FIXATION FOR LUMBAR AND LUMBOSACRAL FUSION - A CLINICAL AND BIOMECHANICAL STUDY
    HEGGENESS, MH
    ESSES, SI
    [J]. SPINE, 1991, 16 (06) : S266 - S269
  • [6] Unilateral versus bilateral pedicle screw instrumentation for single-level minimally invasive transforaminal lumbar interbody fusion
    Shen, Xiaolong
    Zhang, Hailong
    Gu, Xin
    Gu, Guangfei
    Zhou, Xu
    He, Shisheng
    [J]. JOURNAL OF CLINICAL NEUROSCIENCE, 2014, 21 (09) : 1612 - 1616
  • [7] Biomechanical evaluation of four different posterior instrumentation techniques for single-level transforaminal lumbar interbody fusion: a finite element analysis
    Guo, Hui-Zhi
    Tang, Yong-Chao
    Guo, Dan-Qing
    Liang, De
    Zhang, Shun-Cong
    [J]. AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2020, 12 (10): : 6160 - 6169
  • [8] BIOMECHANICAL CONSEQUENCES OF ADJACENT SEGMENT LUMBAR FACET JOINT OSTEOARTHRITIS AFTER POSTERIOR LUMBAR INTERBODY FUSION
    Mecs, L.
    Sohar, G.
    Wellinger, K.
    Toth, K.
    [J]. OSTEOARTHRITIS AND CARTILAGE, 2010, 18 : S230 - S230
  • [9] Physical Therapy Utilization After Single-level Posterior Lumbar Fusion
    Gouzoulis, Michael J.
    Moran, Jay
    Jeong, Seongho
    Galivanche, Anoop R.
    Kammien, Alexander J.
    Jabbouri, Sahir S.
    Grauer, Jonathan N.
    [J]. SPINE, 2024, 49 (17) : E272 - E278
  • [10] Dynamic stabilization adjacent to single-level fusion: Part I. Biomechanical effects on lumbar spinal motion
    Strube, Patrick
    Tohtz, Stephan
    Hoff, Eike
    Gross, Christian
    Perka, Carsten
    Putzier, Michael
    [J]. EUROPEAN SPINE JOURNAL, 2010, 19 (12) : 2171 - 2180