Biomechanical Effects of Facet Joint Violation After Single-Level Lumbar Fusion With Transpedicular Screw and Rod Instrumentation

被引:3
|
作者
Wangsawatwong, Piyanat [1 ]
Pereira, Bernardo de Andrada [1 ]
Lehrman, Jennifer N. [1 ]
Sawa, Anna G. U. [1 ]
O'Neill, Luke K. [1 ]
Turner, Jay D. [1 ]
Uribe, Juan S. [1 ]
Kelly, Brian P. [1 ,2 ]
机构
[1] St Josephs Hosp, Barrow Neurol Inst, Dept Neurosurg, Phoenix, AZ USA
[2] St Josephs Hosp, Barrow Neurol Inst, Neurosci Publicat, 350 W Thomas Rd, Phoenix, AZ 85013 USA
关键词
adjacent-level degeneration; digital imaging correlation; facet violation; intervertebral disc strain; hypermobility; lumbar biomechanics; lumbar fusion; maximum strain; minimum strain; pedicle screw fixation; principal strains; FIXATION;
D O I
10.1097/BRS.0000000000004698
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design.In vitro biomechanical study. Objective.This study aimed to investigate the biomechanical effects of facet joint violation (FV) on mobility and optically tracked intervertebral disc (IVD) surface strains at the upper level adjacent to L4-5 pedicle screw-rod fixation. Summary of Background Data.FV is a complication that can occur when placing lumbar pedicle screws; the reported incidence is as high as 50%. However, little is known about how FV affects superior adjacent-level spinal stability, and especially IVD strain, after lumbar fusion. Methods.Fourteen cadaveric L3-S1 specimens underwent L4-5 pedicle-rod fixation, 7 in the facet joint preservation (FP) group and 7 in the FV group. Specimens were tested multidirectionally under pure moment loading (7.5 Nm). Colored maps of maximum (& epsilon;1) and minimum (& epsilon;2) principal surface strain changes on the lateral L3-4 disc were generated, with the surface divided into 4 quarters anterior to posterior (Q1, Q2, Q3, and Q4, respectively) for subregional analyses. Range of motion (ROM) and IVD strain were normalized to intact upper adjacent-level and compared between the groups using analysis of variance. Statistical significance was set at PResults.Normalized ROM was significantly greater with FV vs. FP in flexion (11% greater; P=0.04), right lateral bending (16% greater; P=0.03), and right axial rotation (23% greater; P=0.04). Normalized L3-4 IVD & epsilon;1 during right lateral bending was greater on average for the FV group than the FP group: Q1, 18% greater; Q2, 12% greater; Q3, 40% greater (P<0.001); Q4, 9% greater. Normalized & epsilon;2 values during left axial rotation were greater in the FV group, the highest increase being 25% in Q3 (P=0.02). Conclusions.Facet joint violation during single-level pedicle screw-rod fixation was associated with increased superior adjacent level mobility and alteration of disc surface strains, with significant increases in selected regions and directions of loading.
引用
收藏
页码:1033 / 1040
页数:8
相关论文
共 50 条
  • [21] A biomechanical comparison of supplementary posterior translaminar facet and transfacetopedicular screw fixation after anterior lumbar interbody fusion
    Kim, SM
    Lima, TJ
    Paterno, J
    Kim, DH
    JOURNAL OF NEUROSURGERY-SPINE, 2004, 1 (01) : 101 - 107
  • [22] Biomechanical effects of screw loosening after lumbar PEEK rod and titanium rod fixation: a finite element analysis
    Jiang, Guozheng
    Wang, Shuyang
    Xu, Luchun
    Li, Zeyu
    Feng, Ningning
    Qiu, Ziye
    Yang, Yongdong
    Yu, Xing
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2025, 13
  • [23] Spontaneous facet joint fusion in patients following oblique lateral lumbar interbody fusion combined with lateral single screw-rod fixation: prevalence, characteristics and significance
    Xingxiao Pu
    Xiandi Wang
    Hongfei Nie
    Tianhang Xie
    Zhiqiang Yang
    Long Zhao
    Run Lin
    Jiancheng Zeng
    European Spine Journal, 2022, 31 : 3580 - 3589
  • [24] Spontaneous facet joint fusion in patients following oblique lateral lumbar interbody fusion combined with lateral single screw-rod fixation: prevalence, characteristics and significance
    Pu, Xingxiao
    Wang, Xiandi
    Nie, Hongfei
    Xie, Tianhang
    Yang, Zhiqiang
    Zhao, Long
    Lin, Run
    Zeng, Jiancheng
    EUROPEAN SPINE JOURNAL, 2022, 31 (12) : 3580 - 3589
  • [25] Bending rod is unnecessary in single-level posterior internal fixation and fusion in treatment of lumbar degenerative diseases
    Xiao Han
    Xin Chen
    Kuan Li
    Zheng Li
    Shugang Li
    BMC Surgery, 21
  • [26] Bending rod is unnecessary in single-level posterior internal fixation and fusion in treatment of lumbar degenerative diseases
    Han, Xiao
    Chen, Xin
    Li, Kuan
    Li, Zheng
    Li, Shugang
    BMC SURGERY, 2021, 21 (01)
  • [27] The biomechanical effect of single-level laminectomy and posterior instrumentation on spinal stability in degenerative lumbar scoliosis: a human cadaveric study
    Rustenburg, Christine M. E.
    Faraj, Sayf S. A.
    Holewijn, Roderick M.
    Kingma, Idsart
    van Royen, Barend J.
    Stadhouder, Agnita
    Emanuel, Kaj S.
    NEUROSURGICAL FOCUS, 2019, 46 (05)
  • [28] In vitro biomechanical comparison of an anterior and anterolateral lumbar plate with posterior fixation following single-level anterior lumbar interbody fusion
    Johnson, Wesley M.
    Nichols, Tann A.
    Jethwani, Deepika
    Guiot, Bernard H.
    JOURNAL OF NEUROSURGERY-SPINE, 2007, 7 (03) : 332 - 335
  • [29] The Impact of Neighborhood Socioeconomic Disadvantage on Operative Outcomes after Single-Level Lumbar Fusion
    Ng, Grace Y.
    Karsalia, Ritesh
    Gallagher, Ryan S.
    Borja, Austin J.
    Na, Jianbo
    McClintock, Scott D.
    Malhotra, Neil R.
    WORLD NEUROSURGERY, 2023, 180 : E440 - E448
  • [30] Risk Factors for and Complications After Surgical Delay in Elective Single-Level Lumbar Fusion
    Wagner, Scott C.
    Butler, Joseph S.
    Kaye, Ian D.
    Sebastian, Arjun S.
    Morrissey, Patrick B.
    Kepler, Christopher K.
    SPINE, 2018, 43 (03) : 228 - 233