Technical factors related to the incidence of adjacent superior segment facet joint violation after transpedicular instrumentation in the lumbar spine

被引:0
|
作者
Zhiming Chen
Jie Zhao
Hao Xu
Aigang Liu
Jiandong Yuan
Cong Wang
机构
[1] The Second Military Medical University,The Department of Orthopedics, Changhai Hospital
来源
European Spine Journal | 2008年 / 17卷
关键词
Pedicle screws; Facet joint violation; Lumbar spine;
D O I
暂无
中图分类号
学科分类号
摘要
Segmental pedicle screw fixation is rapidly becoming a popular method of spinal instrumentation. Few studies have investigated the rates of adjacent superior segment facet joint violation. The purpose of our study were to investigate the incidence of superior segment facet joint violation after pedicle screw instrumentation in the lumbar spine and to evaluate technical factors related to the incidence. A prospective study including 96 patients who underwent lumbar and lumbosacral fusion was conducted between March 2006 and December 2007. All patients had bilateral or unilateral posterior pedicle screw-rod instrumentation with either CD-Horizon (top-loading screw) or TSRH (side-connecting screw) implants. Pedicle screws were instrumented according to the methods advocated by Roy-Camille (Group 1, 20 cases) or Weinstein (Group 2, 76 cases). All patients had computed tomography scan at 1 week post operation. CT scans were reviewed blind by an experienced spine research fellow and a consultant radiologist to determine violation of the adjacent superior segment facet joint. Superior segment facet joint violation occurred in all of the 20 patients (100%) and all of the top-level screws (100%) in Group 1. The spinal research fellow noted the incidence of facet joint violation to be present in 23.8% of the screws and 32.9% of the patients in Group 2, whereas the consultant radiologist noted this to be the case in 25.2 and 35.5%, respectively. The incidence of facet joint violation in patients with CD-Horizon screws was far lower than patients with TSRH screws (P < 0.001). In conclusion, it seems that meticulous surgical dissection without injuring the top-level facet joints, proper instrumentation of pedicle screws with the appropriate entry site (Weinstein’s method), trajectory, and use of top-loading screw heads are some ways that surgeons could minimize the risk of top-level facet joint violation.
引用
收藏
页码:1476 / 1480
页数:4
相关论文
共 43 条
  • [1] Technical factors related to the incidence of adjacent superior segment facet joint violation after transpedicular instrumentation in the lumbar spine
    Chen, Zhiming
    Zhao, Jie
    Xu, Hao
    Liu, Aigang
    Yuan, Jiandong
    Wang, Cong
    [J]. EUROPEAN SPINE JOURNAL, 2008, 17 (11) : 1476 - 1480
  • [2] Radiologic evaluation of adjacent superior segment facet joint violation following transpedicular instrumentation of the lumbar spine
    Shah, RR
    Mohammed, S
    Saifuddin, A
    Taylor, BA
    [J]. SPINE, 2003, 28 (03) : 272 - 275
  • [3] Reviewer’s comment concerning “Technical factors related to the incidence of adjacent superior segment facet joint violation after transpedicular instrumentation in the lumbar spine” (Zhao Jie et al., MS-No. ESJO-D-08-00308)
    Andreas Krödel
    [J]. European Spine Journal, 2008, 17 : 1481 - 1481
  • [4] Reviewer's comment concerning "Technical factors related to the incidence of adjacent superior segment facet joint violation after transpedicular instrumentation in the lumbar spine" (Zhao Jie et al., MS-No. ESJO-D-08-00308)
    Kroedel, Andreas
    [J]. EUROPEAN SPINE JOURNAL, 2008, 17 (11) : 1481 - 1481
  • [5] Does Superior-Segment Facet Violation or Laminectomy Destabilize the Adjacent Level in Lumbar Transpedicular Fixation?
    Cardoso, Mario J.
    Dmitriev, Anton E.
    Helgeson, Melvin
    Lehman, Ronald A.
    Kuklo, Timothy R.
    Rosner, Michael K.
    [J]. SPINE, 2008, 33 (26) : 2868 - 2873
  • [6] Computed tomography evaluation of superior-segment facet-joint violation after pedicle instrumentation of the lumbar spine with a midline surgical approach
    Moshirfar, Ali
    Jenis, Louis G.
    Spector, Leo R.
    Burke, Patrick J.
    Losina, Elena
    Katz, Jeffrey N.
    Rand, Frank F.
    Tromanhauser, Scott G.
    Banco, Robert J.
    [J]. SPINE, 2006, 31 (22) : 2624 - 2629
  • [7] Anatomical and technical factors associated with superior facet joint violation in lumbar fusion
    Teles, Alisson R.
    Paci, Michael
    Gutman, Gabriel
    Abduljabbar, Fahad H.
    Ouellet, Jean A.
    Weber, Michael H.
    Golan, Jeff D.
    [J]. JOURNAL OF NEUROSURGERY-SPINE, 2018, 28 (02) : 173 - 180
  • [8] The Relationship between Adjacent Segment Pathology and Facet Joint Violation by Pedicle Screw after Posterior Lumbar Instrumentation Surgery
    Oh, Ho-Seok
    Seo, Hyoung-Yeon
    [J]. JOURNAL OF CLINICAL MEDICINE, 2021, 10 (13)
  • [9] Biomechanical Effects of Facet Joint Violation After Single-Level Lumbar Fusion With Transpedicular Screw and Rod Instrumentation
    Wangsawatwong, Piyanat
    Pereira, Bernardo de Andrada
    Lehrman, Jennifer N.
    Sawa, Anna G. U.
    O'Neill, Luke K.
    Turner, Jay D.
    Uribe, Juan S.
    Kelly, Brian P.
    [J]. SPINE, 2023, 48 (14) : 1033 - 1040
  • [10] Superior-segment Bilateral Facet Violation in Lumbar Transpedicular Fixation, Part III: A Biomechanical Study of Severe Violation
    Xu, Yunfeng
    Le, Xiaofeng
    Zhang, Qi
    Kuai, Shengzheng
    Leng, Huijie
    Duan, Fangfang
    Shi, Zhan
    Liu, Bo
    He, Da
    Lang, Zhao
    Wu, Jingye
    Wang, Ling
    Tian, Wei
    [J]. SPINE, 2020, 45 (09) : E508 - E514