The effect of different orthodontic mini-implant brands and geometry on primary stability (an in vitro study)

被引:0
|
作者
Abdalla, Khanda Latif [1 ]
Mahmood, Trefa Mohammed Ali [1 ]
机构
[1] Univ Sulaimani, Coll Dent, Dept Pedodont Orthodont & Prevent Dent, Sulaimanyah, Iraq
关键词
Orthodontic mini -implant; Primary stability; Geometry; PULL-OUT STRENGTH; DESIGN CHARACTERISTICS; INSERTION; IMPACT;
D O I
10.1016/j.heliyon.2023.e19858
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: In orthodontic procedures, mini-implants are routinely used as temporary anchorage devices. Early failure is primarily attributed to a variety of issues, which are mostly connected to the quality and geometry of the screw that lead to insufficient primary stability. Objectives: To evaluate the primary stability of different sizes and brands of orthodontic miniimplants by optimizing the insertion torque value (ITV) and to clear out which one has the greatest primary stability among the most widely used mini-implants by orthodontists. Methods: Eighty-two self-drilling mini-implants from three different brands with different sizes were used (Optimus Ortho System (Osteonic made in Korea), Smart anchor (GNI made in Korea) (1.4 x 6, 1.6 x 8 and 1.8 x 10mm) and Morelli (made in Brazil) (1.5 x 6, 1.5 x 8 and 1.5 x 10mm), made from (Ti 6Al 4V). All were drilled at a 60 degrees angle on Sixty artificial bone blocks made from polyurethane foam with a digital torque meter device (Orthonia, Jeil made in Korea), pullout strength (tensile force) was measured with a universal testing machine to find out the best brand and size in the mean of primary stability. Data were analyzed using SPSS Version 25 and JMP Pro Version 16 software using the One-way ANOVA test, the Post hoc and Tukey HCD tests. Results: There were significant differences between the pullout strength of different sizes for the GNI and OSTEONIC brands, while for the MORELLI brand there were no significant differences between the three different sizes considering ITV (10Ncm) whereas for ITV (20Ncm) there was a significant difference between the different sizes for the pullout of all three brands. GNI was the best brand for all the selected sizes with ITV (10Ncm) and size 1.4 x 6 for ITV (20Ncm), whereas OSTEONIC sizes 1.6 x 8 and 1.8 x 10 were the best for ITV (20Ncm) in term of primary stability. Conclusion: GNI screws were demonstrated higher primary among the three widely used brands followed by OSTEONIC for size 1.6 x 8 and 1.8 x 10 while MORELLI was the least resistant to dislodgement for the two torque insertion values 10 N/cm and 20 N/cm.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Biomechanical effect of abutment on stability of orthodontic mini-implant
    Motoyoshi, M
    Yano, S
    Tsuruoka, T
    Shimizu, N
    CLINICAL ORAL IMPLANTS RESEARCH, 2005, 16 (04) : 480 - 485
  • [2] Experimental & FEM Analysis of Orthodontic Mini-Implant Design on Primary Stability
    Mesic, Elmedin
    Muratovic, Enis
    Redzepagic-Vrazalica, Lejla
    Pervan, Nedim
    Muminovic, Adis J.
    Delic, Muamer
    Glusac, Mirza
    APPLIED SCIENCES-BASEL, 2021, 11 (12):
  • [3] Effects of Different Angulation Placement of Mini-Implant in Orthodontic
    Omar, Aisyah
    Ishak, Muhammad Ikman
    Harun, Muhamad Noor
    Sulaiman, Eshamsul
    Abu Kasim, Noor Hayaty
    FRONTIERS OF MANUFACTURING AND DESIGN SCIENCE II, PTS 1-6, 2012, 121-126 : 1214 - +
  • [5] Orthodontic mini-implant stability and the ratio of pilot hole implant diameter
    Uemura, Miwa
    Motoyoshi, Mitsuru
    Yano, Shinya
    Sakaguchi, Masahito
    Igarashi, Yu
    Shimizu, Noriyoshi
    EUROPEAN JOURNAL OF ORTHODONTICS, 2012, 34 (01) : 52 - 56
  • [6] Orthodontic mini-implant stability at different insertion depths Sensitivity of three stability measurement methods
    Nienkemper, Manuel
    Santel, Natascha
    Hoenscheid, Ralf
    Drescher, Dieter
    JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2016, 77 (04): : 296 - 303
  • [7] Influence of bone architecture on the primary stability of different mini-implant designs
    da Cunha, Amanda Carneiro
    Marquezan, Mariana
    Lima, Inaya
    Lopes, Ricardo Tadeu
    Nojima, Lincoln Issamu
    Sant'Anna, Eduardo Franzotti
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2015, 147 (01) : 45 - 51
  • [8] Mechanical influence of thread pitch on orthodontic mini-implant stability
    da Cunha, Amanda Carneiro
    Ayres de Freitas, Amanda Osorio
    Marquezan, Mariana
    Nojima, Lincoln Issamu
    BRAZILIAN ORAL RESEARCH, 2015, 29 (01): : 1 - 6
  • [9] Primary migration of a mini-implant under a functional orthodontic loading
    Pittman, Joseph W.
    Navalgund, Anand
    Byun, Steve H.
    Huang, Hechang
    Kim, Albert H.
    Kim, Do-Gyoon
    CLINICAL ORAL INVESTIGATIONS, 2014, 18 (03) : 721 - 728
  • [10] Primary migration of a mini-implant under a functional orthodontic loading
    Joseph W. Pittman
    Anand Navalgund
    Steve H. Byun
    Hechang Huang
    Albert H. Kim
    Do-Gyoon Kim
    Clinical Oral Investigations, 2014, 18 : 721 - 728