Marginal Accuracy of Monolithic and Veneered Zirconia Crowns Fabricated by Conventional and Digital Workflows

被引:3
|
作者
Abduo, Jaafar [1 ,2 ]
Ho, Grace [1 ]
Centorame, Alannah [1 ]
Chohan, Simran [1 ]
Park, Clara [1 ]
Abdouni, Ramiz [1 ]
Le, Phillip [1 ]
机构
[1] Univ Melbourne, Melbourne Dent Sch, Restorat Sect, Melbourne, Vic, Australia
[2] Univ Melbourne, Melbourne Dent Sch, 720 Swanston St, Melbourne, Vic 3010, Australia
关键词
3D printing; impression; intraoral scanner; marginal accuracy; seating; zirconia; CERAMIC CROWNS; INTERNAL FIT; ADAPTATION; 3D; IMPRESSIONS; CASTS;
D O I
10.1111/jopr.13618
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PurposeTo compare the marginal accuracy of zirconia crowns fabricated by different workflows (conventional and digital) and designs (monolithic and veneered). Materials and MethodsA prepared maxillary first molar was used for the study. Four workflow combinations were evaluated: (1) intraoral scanning and monolithic zirconia (IOS-M), (2) intraoral scanning and veneered zirconia (IOS-V), (3) conventional impression and monolithic zirconia (IMP-M), and (4) conventional impression and veneered zirconia (IMP-V). All of the specimens had similar designs. The veneered groups had a buccal cutback for esthetic veneer application. A total of 10 crowns were produced in each workflow. The vertical and horizontal marginal accuracies were measured with a traveling microscope. Depending on the normality of the data, one-way analysis of variance test or Kruskal-Wallis test were applied to evaluate the differences among the groups (alpha = 0.05). ResultsThe most superior vertical marginal accuracy was observed for IOS-V (mean = 22.5 mu m; SD = 6.7 mu m), followed by IMP-V (mean = 23.9 mu m; SD = 7.8 mu m), IOS-M (mean = 28.7 mu m; SD = 10.3 mu m), and IMP-M (mean = 39.8 mu m; SD = 22.0 mu m), respectively (p < 0.001). The IOS-M had the greatest mean horizontal discrepancies (mean = 23.9 mu m; SD = 4.3 mu m) followed by IMP-M (mean = 21.3 mu m; SD = 5.7 mu m), IMP-V (mean = 19.2 mu m; SD = 5.3 mu m) and IOS-V (mean = 17.6 mu m; SD = 5.7 mu m) (p < 0.001). ConclusionsMonolithic zirconia crowns fabricated digitally had superior marginal accuracy than monolithic zirconia crowns fabricated conventionally. Esthetic buccal veneering of predominantly monolithic zirconia copings improved the vertical and horizontal marginal accuracies.
引用
收藏
页码:706 / 713
页数:8
相关论文
共 50 条
  • [41] Marginal fit of zirconia copings fabricated after conventional impression making and digital scanning: An in vitro study
    Vaz, Ines Margarida Carrilho Baltazar
    Carracho, Jose Fausto Pimentel Coelho Lino
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (02): : 223.e1 - 223.e6
  • [42] Seating accuracy of removable partial denture frameworks fabricated by different digital workflows in comparison to conventional workflow
    Korkes, Andrea
    Jomaa, Janine
    Kavouris, Anastasios
    Lalani, Tahyr
    King, Phillip
    Lee, Samantha
    Li, Hongyi
    Li, Aixi
    Khuu, Wilson
    Law, Ka Ho Jesper
    Abduo, Jaafar
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024,
  • [43] Fracture Resistance of Monolithic High-Translucency Crowns Versus Porcelain-Veneered Zirconia Crowns After Artificial Aging: An In Vitro Study
    Ezzat, Yousef
    Sharka, Rayan
    Rayyan, Mohammad
    Al-Rafee, Mohammed
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (12)
  • [44] Fracture resistance of CAD-CAM monolithic ceramic and veneered zirconia molar crowns after aging in a mastication simulator
    Gungor, Merve Bankoglu
    Nemli, Secil Karakoca
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (03): : 473 - 480
  • [45] Comparison of Fracture Resistance Between Two Monolithic and One Veneered Zirconia Materials on Molar Crowns After Thermomechanical Fatigue
    Kayali, Faisal
    Kahramanoglu, Erkut
    CLINICAL AND EXPERIMENTAL HEALTH SCIENCES, 2020, 10 (03): : 320 - 326
  • [46] Five-year clinical performance of monolithic and partially veneered zirconia single crowns-a prospective observational study
    Waldecker, Moritz
    Behnisch, Rouven
    Rammelsberg, Peter
    Boemicke, Wolfgang
    JOURNAL OF PROSTHODONTIC RESEARCH, 2022, 66 (02) : 339 - 345
  • [47] Accuracy of single crowns fabricated from ultrasound digital impressions
    Praca, Luciano
    Pekam, Fabrice Chuembou
    Rego, Rodrigo Otavio
    Radermacher, Klaus
    Wolfart, Stefan
    Marotti, Juliana
    DENTAL MATERIALS, 2018, 34 (11) : E280 - E288
  • [48] Fitting accuracy of zirconia single crowns produced via digital and conventional impressions-a clinical comparative study
    Roediger, Matthias
    Heinitz, Arthur
    Buergers, Ralf
    Rinke, Sven
    CLINICAL ORAL INVESTIGATIONS, 2017, 21 (02) : 579 - 587
  • [49] Effect of fabrication stages and cementation on the marginal fit of CAD-CAM monolithic zirconia crowns
    Kale, Ediz
    Yilmaz, Burak
    Seker, Emre
    Ozcelik, Tuncer Burak
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 118 (06): : 736 - 741
  • [50] Effect of machining method and margin design on the accuracy and margin quality of monolithic zirconia crowns
    Zhou, Yi
    Chen, Wenjia
    Zhu, Han
    Liu, Xiaochen
    Yang, Haiping
    He, Fuming
    JOURNAL OF PROSTHETIC DENTISTRY, 2025, 133 (02):