Fitting accuracy of zirconia single crowns produced via digital and conventional impressions-a clinical comparative study

被引:61
|
作者
Roediger, Matthias [1 ]
Heinitz, Arthur [1 ]
Buergers, Ralf [1 ]
Rinke, Sven [1 ]
机构
[1] Georg August Univ, Dept Prosthodont, Univ Med Ctr Goettingen, Robert Koch Str 40, D-37075 Gottingen, Germany
关键词
Zirconia crown; Digital impression; Cad/Cam; Fitting accuracy; Replica technique; MARGINAL FIT; CERAMIC CROWNS; IN-VITRO; RESTORATIONS; TECHNOLOGY; PERCEPTION; SILICONE; WORKFLOW; SYSTEMS;
D O I
10.1007/s00784-016-1924-y
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study focused on the clinical investigation of the internal and marginal fit of CAD/CAM-fabricated zirconia single crowns produced via conventional and digital impression techniques. In a private practice, 20 molar teeth, one from each of 20 patients, were prepared with a circumferential 1.0-mm deep chamfer and an occlusal reduction of 1.5 mm. Conventional impression (CI) taking with a polyvinylsiloxane material (Aquasil Monophase + Aquasil XLV; Dentsply, Konstanz, Germany) and intraoral scanning (IS) (Cara TRIOS; Heraeus, Hanau, Germany) of each of the preparations was performed, and then two respective zirconia copings per tooth were produced (20 crowns per group). The marginal and internal fit of the restorations was evaluated employing a replica technique. For statistical analysis, a pairwise comparison (Wilcoxon rank test) was performed. Zirconia single crowns produced with the IS technique revealed a statistically significant better precision of internal fit only in specific areas (chamfer area/occlusal area). The evaluation of marginal fit showed no significant differences between the two groups. All restorations of both groups offered internal and marginal gaps within the postulated clinical tolerance ranges. CAD/CAM-fabricated zirconia single crowns produced with CI and IS techniques offer adequate marginal and internal precision. However, the IS technique provides lower internal gaps in some specific areas. The clinical precision of fit of restorations produced with a CI and an IS technique appeared to be equivalent. Therefore, the IS technique can be rated as a suitable alternative for the manufacturing of single crowns.
引用
收藏
页码:579 / 587
页数:9
相关论文
共 50 条
  • [1] Fitting accuracy of zirconia single crowns produced via digital and conventional impressions—a clinical comparative study
    Matthias Rödiger
    Arthur Heinitz
    Ralf Bürgers
    Sven Rinke
    Clinical Oral Investigations, 2017, 21 : 579 - 587
  • [2] Accuracy of Digital Impressions and Fitness of Single Crowns Based on Digital Impressions
    Yang, Xin
    Lv, Pin
    Liu, Yihong
    Si, Wenjie
    Feng, Hailan
    MATERIALS, 2015, 8 (07): : 3945 - 3957
  • [3] Accuracy of digital and conventional implant impressions in edentulous jaws: A clinical comparative study
    Kernen-Gintaute, A.
    Akulauskas, M.
    Kernen, F.
    Zitzmann, N. U.
    Spies, B. C.
    Burkhardt, F.
    JOURNAL OF DENTISTRY, 2025, 153
  • [4] Comparative study of all-ceramic crowns obtained from conventional and digital impressions: clinical findings
    Santiago Berrendero
    Maria Paz Salido
    Alberto Ferreiroa
    Arelhys Valverde
    Guillermo Pradíes
    Clinical Oral Investigations, 2019, 23 : 1745 - 1751
  • [5] Comparative study of all-ceramic crowns obtained from conventional and digital impressions: clinical findings
    Berrendero, Santiago
    Paz Salido, Maria
    Ferreiroa, Alberto
    Valverde, Arelhys
    Pradies, Guillermo
    CLINICAL ORAL INVESTIGATIONS, 2019, 23 (04) : 1745 - 1751
  • [6] Comparison of accuracy of single crowns generated from digital and conventional impressions: an in vivo controlled trial
    Di Fiore, A.
    De Francesco, M.
    Monaco, C.
    Stocco, E.
    Vigolo, P.
    Stellini, E.
    JOURNAL OF OSSEOINTEGRATION, 2019, 11 (02) : 107 - 112
  • [7] Accuracy of single crowns fabricated from ultrasound digital impressions
    Praca, Luciano
    Pekam, Fabrice Chuembou
    Rego, Rodrigo Otavio
    Radermacher, Klaus
    Wolfart, Stefan
    Marotti, Juliana
    DENTAL MATERIALS, 2018, 34 (11) : E280 - E288
  • [8] Accuracy of digital and conventional dental implant impressions for fixed partial dentures: A comparative clinical study
    Gedrimiene, Agne
    Adaskevicius, Rimas
    Rutkunas, Vygandas
    JOURNAL OF ADVANCED PROSTHODONTICS, 2019, 11 (05): : 271 - 279
  • [9] Accuracy of impressions for multiple implants: A comparative study of digital and conventional techniques
    Lyu, Mingyue
    Di, Ping
    Lin, Ye
    Jiang, Xi
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (05): : 1017 - 1023
  • [10] Marginal Accuracy of Monolithic and Veneered Zirconia Crowns Fabricated by Conventional and Digital Workflows
    Abduo, Jaafar
    Ho, Grace
    Centorame, Alannah
    Chohan, Simran
    Park, Clara
    Abdouni, Ramiz
    Le, Phillip
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (08): : 706 - 713