One-way shaking table test study of resilient steel frame with seismic isolated floor system

被引:1
|
作者
Zhang, Yanxia [1 ]
Wu, Binglong [2 ]
Li, Yanglong [2 ]
Xiao, Chenyu [2 ]
Zhang, Hao [2 ]
机构
[1] Beijing Univ Civil Engn & Architecture, Collaborat Innovat Ctr Energy Conservat & Emiss Re, Beijing 100044, Peoples R China
[2] Beijing Univ Civil Engn & Architecture, Beijing 100044, Peoples R China
关键词
Seismically insulated floorings systems; Resilient functional steel frames; Shaking table tests; Expansion effects; Post -earthquake resilience;
D O I
10.1016/j.jcsr.2024.108545
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents a novel seismic isolation floor system that aims to address the issue of incongruent deformation between the floor and the resilient steel frame structure. The proposed study introduces a design methodology for the seismic isolation floor system, along with the consideration of its impact on the resilient beam-column nodes. Subsequently, a scaled-down test model is built and constructed, consisting of three stories with a height of 1.2 m and a 2 x 2 span configuration, in accordance with the aforementioned design methodology. The experimental study involved conducting unidirectional shaking table tests on the model in both horizontal directions. The scaled-down model was subjected to seismic excitations of varying intensities, ranging from an 8-degree multiple-occurrence earthquake to a 9-degree rare-occurrence earthquake. Additionally, an extremely rare-occurrence earthquake with an acceleration of 0.75 g was also applied to the model. The test results indicate that the beam-column node exhibits a maximum opening of 4.56 mm and an angle of rotation of 3.04%. Furthermore, the seismic isolation building system demonstrates the ability to accommodate the "expansion effect" of the resilient structure, while simultaneously maintaining load carrying capacity and effectively transmitting horizontal forces. The seismic isolation floor exhibits a notable reduction of 54.8% in its maximum horizontal inertia force, hence demonstrating a favourable damping effect. Based on the observed alterations in the X-direction frequency of the structure prior to and after to the seismic event with a PGA of 0.07 g, it can be inferred that the beam-column connections inside the structure may be deemed as stiff when subjected to several earthquakes. In the PGA = 0.75 g scenario, the maximum interstory displacement angle of 1/69 is observed in the X direction of the 2nd floor. This value is in close proximity to the elastic-plastic interstory displacement angle of 1/50. However, there is no visible deformation or damage to the structure as a whole, and the strain of each member remains within the elastic range, not exceeding 1675 mu epsilon. Hence, it is widely acknowledged that the resilient steel frame, equipped with a seismic isolation floor system, exhibits robust postearthquake functional resilience in the face of unidirectional seismic activity.
引用
收藏
页数:20
相关论文
共 50 条
  • [41] Shaking table test of a RC frame structure with different cross-section columns of stilted floor
    Tang Y.
    Li Y.
    Liu L.
    Jiang B.
    Yu H.
    Ji S.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2023, 42 (01): : 19 - 27
  • [42] Shaking table test on vertical seismic responses of isolated large-span structure
    Xu W.
    Wang S.
    Liu W.
    Du D.
    Gu Z.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2020, 41 (04): : 19 - 31
  • [43] Shaking table test of a timber building equipped with a novel cost-effective, impact-resilient seismic isolation system
    Quizanga, D.
    Almazan, J. L.
    Valdivieso, D.
    Lopez-Garcia, D.
    Guindos, P.
    JOURNAL OF BUILDING ENGINEERING, 2024, 82
  • [44] Seismic Vulnerability Analysis of Steel Damping Slide Bearing Based on Shaking Table Test
    Xia Z.
    Lin Y.
    Zhang J.
    Peng W.
    Tiedao Xuebao/Journal of the China Railway Society, 2021, 43 (03): : 158 - 165
  • [45] Experimental study on seismic performance of steel frame and light-frame timber shear wall hybrid structure through shaking table tests
    He M.
    Luo Q.
    Dong H.
    Li Z.
    Li M.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2019, 40 (09): : 1 - 9
  • [46] Shaking table test and numerical damage behaviour analysis of a steel portal frame with bolted connections
    Saranik, Mohammad
    Lenoir, David
    Jezequel, Louis
    COMPUTERS & STRUCTURES, 2012, 112 : 327 - 341
  • [47] Shaking table test of a light steel frame structure with micro-crystalline foam plates
    Dong H.
    Yang L.
    Cao W.
    Lü X.
    Bian J.
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2019, 51 (12): : 27 - 34
  • [48] DYNAMIC INELASTIC NUMERICAL SIMULATION ON A SHAKING TABLE TEST OF A FULL SCALE STEEL MOMENT FRAME
    Chen, Xue-Wei
    Han, Xiao-Lei
    Lin, Sheng-Yi
    ISISS '2009: INNOVATION & SUSTAINABILITY OF STRUCTURES, VOLS 1 AND 2, 2009, : 1367 - 1372
  • [49] Shaking table testing of a steel frame structure with and without Tuned Mass Control System
    Jurukovski, D.
    Nawrotzki, P.
    Rakicevic, Z.
    Structural Dynamics - EURODYN 2005, Vols 1-3, 2005, : 1599 - 1603
  • [50] Experiment on Seismic Performance of Frame-Masonry Horizontal Hybrid Structure Based on Shaking Table Test
    Zheng G.
    Xu H.
    Wu Y.
    Journal of Shanghai Jiaotong University (Science), 2019, 24 (05) : 640 - 646