One-way shaking table test study of resilient steel frame with seismic isolated floor system

被引:1
|
作者
Zhang, Yanxia [1 ]
Wu, Binglong [2 ]
Li, Yanglong [2 ]
Xiao, Chenyu [2 ]
Zhang, Hao [2 ]
机构
[1] Beijing Univ Civil Engn & Architecture, Collaborat Innovat Ctr Energy Conservat & Emiss Re, Beijing 100044, Peoples R China
[2] Beijing Univ Civil Engn & Architecture, Beijing 100044, Peoples R China
关键词
Seismically insulated floorings systems; Resilient functional steel frames; Shaking table tests; Expansion effects; Post -earthquake resilience;
D O I
10.1016/j.jcsr.2024.108545
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents a novel seismic isolation floor system that aims to address the issue of incongruent deformation between the floor and the resilient steel frame structure. The proposed study introduces a design methodology for the seismic isolation floor system, along with the consideration of its impact on the resilient beam-column nodes. Subsequently, a scaled-down test model is built and constructed, consisting of three stories with a height of 1.2 m and a 2 x 2 span configuration, in accordance with the aforementioned design methodology. The experimental study involved conducting unidirectional shaking table tests on the model in both horizontal directions. The scaled-down model was subjected to seismic excitations of varying intensities, ranging from an 8-degree multiple-occurrence earthquake to a 9-degree rare-occurrence earthquake. Additionally, an extremely rare-occurrence earthquake with an acceleration of 0.75 g was also applied to the model. The test results indicate that the beam-column node exhibits a maximum opening of 4.56 mm and an angle of rotation of 3.04%. Furthermore, the seismic isolation building system demonstrates the ability to accommodate the "expansion effect" of the resilient structure, while simultaneously maintaining load carrying capacity and effectively transmitting horizontal forces. The seismic isolation floor exhibits a notable reduction of 54.8% in its maximum horizontal inertia force, hence demonstrating a favourable damping effect. Based on the observed alterations in the X-direction frequency of the structure prior to and after to the seismic event with a PGA of 0.07 g, it can be inferred that the beam-column connections inside the structure may be deemed as stiff when subjected to several earthquakes. In the PGA = 0.75 g scenario, the maximum interstory displacement angle of 1/69 is observed in the X direction of the 2nd floor. This value is in close proximity to the elastic-plastic interstory displacement angle of 1/50. However, there is no visible deformation or damage to the structure as a whole, and the strain of each member remains within the elastic range, not exceeding 1675 mu epsilon. Hence, it is widely acknowledged that the resilient steel frame, equipped with a seismic isolation floor system, exhibits robust postearthquake functional resilience in the face of unidirectional seismic activity.
引用
收藏
页数:20
相关论文
共 50 条
  • [21] Shaking table test of steel frame structure with particle tuned mass damper
    Lu Z.
    Zhang D.
    Lu X.
    1600, Science Press (38): : 10 - 17
  • [22] A model shaking table test of concrete filled steel tubular frame structure
    Du, Guofeng
    Xu, Lihua
    Chi, Yin
    Song, Zhibin
    PROCEEDINGS OF INTERNATIONAL CONFERENCE ON HEALTH MONITORING OF STRUCTURE, MATERIALS AND ENVIRONMENT, VOLS 1 AND 2, 2007, : 1065 - 1070
  • [23] Damage detection and estimation of a steel frame through shaking table test and measurements
    Morita, K
    Teshigawara, M
    SMART STRUCTURES AND MATERIALS 2004: SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS, 2004, 5391 : 695 - 704
  • [24] Shaking table test of special concentrically braced steel frame with pinned connections
    Zhang W.
    Mai H.
    Yu H.
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2016, 48 (06): : 17 - 24
  • [25] Shaking table test on prefabricated steel frame structure with ribbed thin walls
    Zhang Z.
    Cao W.
    Wang R.
    Hou J.
    Chen Y.
    Li D.
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2020, 52 (10): : 10 - 18
  • [26] Shaking table test study on the seismic isolation effect of a hybrid passive control system
    Wu, Qiaoyun
    Yan, Huichao
    Zhu, Hongping
    Bai, Xixuan
    MEASUREMENT, 2020, 164
  • [27] Shaking table test on the seismic performance of ternary composite geopolymer recycled concrete frame
    Li, Yin
    Huang, Liang
    Qu, Yiqun
    Liu, Haoqi
    Lv, Bodong
    Li, Shuisheng
    STRUCTURES, 2024, 65
  • [28] Probabilistic evaluation of seismic performance of 3D one-way and two-way steel moment frame structures
    Tagawa, Hiroyuki
    MacRae, Gregory
    Lowes, Laura
    Stessa 2006, 2006, : 91 - 97
  • [29] Shaking table test on hybrid structure with SRC frame and steel frame strengthened concrete core tube
    Du W.
    Zhang L.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2016, 37 (07): : 127 - 135
  • [30] Shaking table test on isolated step-terrace frame structure in mountainous area
    Zhang L.
    Tao Z.
    Pan W.
    Wu Z.
    Lan X.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2020, 41 (09): : 24 - 32and44