One-way shaking table test study of resilient steel frame with seismic isolated floor system

被引:1
|
作者
Zhang, Yanxia [1 ]
Wu, Binglong [2 ]
Li, Yanglong [2 ]
Xiao, Chenyu [2 ]
Zhang, Hao [2 ]
机构
[1] Beijing Univ Civil Engn & Architecture, Collaborat Innovat Ctr Energy Conservat & Emiss Re, Beijing 100044, Peoples R China
[2] Beijing Univ Civil Engn & Architecture, Beijing 100044, Peoples R China
关键词
Seismically insulated floorings systems; Resilient functional steel frames; Shaking table tests; Expansion effects; Post -earthquake resilience;
D O I
10.1016/j.jcsr.2024.108545
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents a novel seismic isolation floor system that aims to address the issue of incongruent deformation between the floor and the resilient steel frame structure. The proposed study introduces a design methodology for the seismic isolation floor system, along with the consideration of its impact on the resilient beam-column nodes. Subsequently, a scaled-down test model is built and constructed, consisting of three stories with a height of 1.2 m and a 2 x 2 span configuration, in accordance with the aforementioned design methodology. The experimental study involved conducting unidirectional shaking table tests on the model in both horizontal directions. The scaled-down model was subjected to seismic excitations of varying intensities, ranging from an 8-degree multiple-occurrence earthquake to a 9-degree rare-occurrence earthquake. Additionally, an extremely rare-occurrence earthquake with an acceleration of 0.75 g was also applied to the model. The test results indicate that the beam-column node exhibits a maximum opening of 4.56 mm and an angle of rotation of 3.04%. Furthermore, the seismic isolation building system demonstrates the ability to accommodate the "expansion effect" of the resilient structure, while simultaneously maintaining load carrying capacity and effectively transmitting horizontal forces. The seismic isolation floor exhibits a notable reduction of 54.8% in its maximum horizontal inertia force, hence demonstrating a favourable damping effect. Based on the observed alterations in the X-direction frequency of the structure prior to and after to the seismic event with a PGA of 0.07 g, it can be inferred that the beam-column connections inside the structure may be deemed as stiff when subjected to several earthquakes. In the PGA = 0.75 g scenario, the maximum interstory displacement angle of 1/69 is observed in the X direction of the 2nd floor. This value is in close proximity to the elastic-plastic interstory displacement angle of 1/50. However, there is no visible deformation or damage to the structure as a whole, and the strain of each member remains within the elastic range, not exceeding 1675 mu epsilon. Hence, it is widely acknowledged that the resilient steel frame, equipped with a seismic isolation floor system, exhibits robust postearthquake functional resilience in the face of unidirectional seismic activity.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Shaking table test of prefabricated equipment cabins with a resilient steel frame at the bottom
    Feng, Yulong
    Zeng, Zhihao
    Jiang, Qing
    Zeng, Tianshu
    Chong, Xun
    Huang, Junqi
    ENGINEERING STRUCTURES, 2025, 322
  • [2] A SHAKING TABLE TEST FOR THE EVALUATION OF FLOOR RESPONSE SPECTRUM OF SEISMIC ISOLATED NPP STRUCTURE
    Kim, Min Kyu
    Kim, Jung Han
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE, 2016, VOL 8, 2017,
  • [3] Shaking Table Model Test of Steel Frame Structure
    Cao Yu-sheng
    Zhao Ya-ling
    Li Jie
    PROGRESS IN STRUCTURE, PTS 1-4, 2012, 166-169 : 343 - 348
  • [4] Shaking table test study on seismic performance of RC frame structure with NES
    Yang, Haixu
    Li, Zhuo
    Wang, Haibiao
    Zhang, Maohua
    Ni, Songyuan
    STRUCTURES, 2023, 47 : 153 - 164
  • [5] Shaking Table Test on Seismic Response of Isolated Bridge
    Yan, Xiaoyu
    Wang, Lihui
    Du, Xiuli
    APPLIED MECHANICS AND MATERIALS I, PTS 1-3, 2013, 275-277 : 1034 - +
  • [6] Shaking table test study on friction-pendulum isolated frame structures
    Zheng, Jiayi
    Song, Wei
    Lei, Yuande
    Wang, Tao
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2020, 53 : 240 - 245
  • [7] Shaking Table Test for Evaluating the Seismic Performance of Steel Frame Retrofitted by Buckling-Restrained Braces
    Wang, Tingting
    Shao, Jianhua
    Zhao, Chao
    Liu, Wenjin
    Wang, Zhanguang
    SHOCK AND VIBRATION, 2021, 2021
  • [8] Study on shaking table test of steel frame structure with enhanced particle inerter device
    Lu Z.
    Zhou C.
    Yan D.
    Zhang R.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2023, 44 : 48 - 55
  • [9] Experimental study on the floor responses of a base-isolated frame structure via shaking table tests
    Jung, Jae-Wook
    Kim, Min Kyu
    Kim, Jung Han
    ENGINEERING STRUCTURES, 2022, 253
  • [10] Shaking table test of steel frame with ALC external wall panels
    Fang Ming-Ji
    Wang Jing-Feng
    Li Guo-Qiang
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2013, 80 : 278 - 286