Proximal radiolucent lines around fully hydroxyapatite-coated tapered femoral stems: should we be concerned?

被引:0
|
作者
Berliner, Zachary P. [1 ]
Jawad, Muhammad Umar [2 ]
Matzko, Chelsea [3 ]
Cooper, H. John [4 ]
Rodriguez, Jose A. [5 ]
Hepinstall, Matthew S. [6 ,7 ]
机构
[1] Boston Univ Med Ctr, Dept Orthopaed Surg, Boston, MA USA
[2] Univ Calif Davis, Dept Orthopaed Surg, Sacramento, CA USA
[3] Lenox Hill Hosp, Dept Orthopaed Surg, Northwell Hlth, New York, NY USA
[4] Columbia Univ Med Ctr, Dept Orthopaed Surg, New York, NY USA
[5] Hosp Special Surg, Dept Orthopaed Surg, Adult Reconstruct & Joint Replacement Serv, New York, NY USA
[6] NYU Langone Hlth, Dept Orthopaed Surg, New York, NY USA
[7] NYU Langone Orthoped Hosp, 301 E 17th St,Suite 1402, New York, NY 10003 USA
关键词
Arthroplasty; femoral stem; hydroxyapatite; outcomes; radiolucent line; TOTAL HIP-ARTHROPLASTY; CANAL FILL RATIO; RADIOGRAPHIC OUTCOMES; CEMENTLESS; REPLACEMENT; MORPHOLOGY; COMPONENTS;
D O I
10.1177/11207000231178269
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Radiolucent lines occasionally develop around the proximal aspect of fully hydroxyapatite (HA)-coated tapered femoral stems after total hip arthroplasty (THA). It was hypothesised that distal wedging of stems may predispose to proximal radiolucent line formation, which may negatively impact clinical outcome. Methods: All primary THA performed with a collarless fully HA-coated stem that had a minimum of 1 year of radiographic follow-up were identified in a surgical database (n = 244). Radiographic measures of proximal femoral morphology and femoral canal fill at the middle and distal thirds of the stem were analysed for association with the presence of proximal radiolucent lines. Linear regression was used to explore any association between radiolucent lines and patient reported outcome measures (PROMs), available in 61% of patients. Results: Proximal radiolucent lines developed in 31 cases (12.7%) at final follow-up. Dorr A femoral morphology and increased canal-fill at the distal 1/3 of the stem correlated with the development of radiolucent lines (p < 0.001). No correlation was observed between pain or PROMs and the presence of proximal radiolucent lines. Discussion: We observed an unexpectedly high incidence of proximal femoral radiolucent lines about collarless fully HA coated stems. Distal-only implant wedging in Dorr A bone may compromise proximal fixation. Although this finding did not correlate with short-term outcomes, the long-term clinical impact requires further study.
引用
下载
收藏
页码:49 / 56
页数:8
相关论文
共 50 条
  • [41] Comparison of canal fill and radiolucent line formation between two fully coated, hydroxyapatite tapered stems: a 2-year follow-up after total hip arthroplasty
    Shichman, Ittai
    Lawrence, Kyle W. W.
    Berzolla, Emily
    Hernandez, Carlos Sandoval
    Man-El, Rani
    Warschawski, Yaniv
    Snir, Nimrod
    Schwarzkopf, Ran
    Hepinstall, Matthew S. S.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (11) : 6945 - 6954
  • [42] Femoral revision surgery using a fully hydroxyapatite-coated stem: a cohort study of twenty two to twenty seven years
    Olav Reikerås
    International Orthopaedics, 2017, 41 : 271 - 275
  • [43] Femoral revision surgery using a fully hydroxyapatite-coated stem: a cohort study of twenty two to twenty seven years
    Reikeras, Olav
    INTERNATIONAL ORTHOPAEDICS, 2017, 41 (02) : 271 - 275
  • [44] Clinical and Radiologic Outcomes of a Fully Hydroxyapatite-Coated Femoral Revision Stem: Excessive Stress Shielding Incidence and its Consequences
    Sanli, Ilknur
    Arts, Jacobus Johannes Christiaan
    Geurts, Jan
    JOURNAL OF ARTHROPLASTY, 2016, 31 (01): : 209 - 214
  • [45] No Impact of Contact Between the Medial Collar of a Hydroxyapatite-Coated Triple-Tapered Stem and the Femoral Neck on Periprosthetic Bone Mineral Density
    Iwakiri, Kentaro
    Ohta, Yoichi
    Minoda, Yukihide
    Ueno, Shuhei
    Kobayashi, Akio
    Nakamura, Hiroaki
    JOURNAL OF ARTHROPLASTY, 2024, 39 (08): : 2082 - 2087
  • [46] A double tapered fully hydroxyapatite-coated stem has less contact area to femoral cortical bone than a tapered-wedge stem: a three-dimensional computed tomography-based density mapping analysis
    Ohyama, Yohei
    Minoda, Yukihide
    Ohta, Yoichi
    Sugama, Ryo
    Takemura, Susumu
    Nakamura, Hiroaki
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (07) : 4465 - 4472
  • [47] Fully hydroxyapatite-coated distal locking cementless femoral modular implant for revision total hip arthroplasty: A retrospective study of 94 Renaissance™ stems at a minimum 10 years' follow-up
    Slomka, Fabien
    Druon, Jerome
    Rosset, Philippe
    Le Nail, Louis-Romee
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2022, 108 (06)
  • [48] A double tapered fully hydroxyapatite-coated stem has less contact area to femoral cortical bone than a tapered-wedge stem: a three-dimensional computed tomography-based density mapping analysis
    Yohei Ohyama
    Yukihide Minoda
    Yoichi Ohta
    Ryo Sugama
    Susumu Takemura
    Hiroaki Nakamura
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 4465 - 4472
  • [49] Long-Term Remodeling in Proximal Femur Around a Hydroxyapatite-Coated Anatomic Stem Ten Years Densitometric Follow-Up
    Panisello, Juan J.
    Herrero, Luis
    Canales, Vicente
    Herrera, Antonio
    Martinez, Angel A.
    Mateo, Jesus
    JOURNAL OF ARTHROPLASTY, 2009, 24 (01): : 56 - 64
  • [50] Fully hydroxyapatite-coated compaction broached and triple-tapered stem may reduce the risk of stress shielding after primary total hip arthroplasty
    Yuichi Kuroda
    Shingo Hashimoto
    Shinya Hayashi
    Naoki Nakano
    Takaaki Fujishiro
    Takafumi Hiranaka
    Ryosuke Kuroda
    Tomoyuki Matsumoto
    Archives of Orthopaedic and Trauma Surgery, 2022, 142 : 4087 - 4093