Proximal radiolucent lines around fully hydroxyapatite-coated tapered femoral stems: should we be concerned?

被引:0
|
作者
Berliner, Zachary P. [1 ]
Jawad, Muhammad Umar [2 ]
Matzko, Chelsea [3 ]
Cooper, H. John [4 ]
Rodriguez, Jose A. [5 ]
Hepinstall, Matthew S. [6 ,7 ]
机构
[1] Boston Univ Med Ctr, Dept Orthopaed Surg, Boston, MA USA
[2] Univ Calif Davis, Dept Orthopaed Surg, Sacramento, CA USA
[3] Lenox Hill Hosp, Dept Orthopaed Surg, Northwell Hlth, New York, NY USA
[4] Columbia Univ Med Ctr, Dept Orthopaed Surg, New York, NY USA
[5] Hosp Special Surg, Dept Orthopaed Surg, Adult Reconstruct & Joint Replacement Serv, New York, NY USA
[6] NYU Langone Hlth, Dept Orthopaed Surg, New York, NY USA
[7] NYU Langone Orthoped Hosp, 301 E 17th St,Suite 1402, New York, NY 10003 USA
关键词
Arthroplasty; femoral stem; hydroxyapatite; outcomes; radiolucent line; TOTAL HIP-ARTHROPLASTY; CANAL FILL RATIO; RADIOGRAPHIC OUTCOMES; CEMENTLESS; REPLACEMENT; MORPHOLOGY; COMPONENTS;
D O I
10.1177/11207000231178269
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Radiolucent lines occasionally develop around the proximal aspect of fully hydroxyapatite (HA)-coated tapered femoral stems after total hip arthroplasty (THA). It was hypothesised that distal wedging of stems may predispose to proximal radiolucent line formation, which may negatively impact clinical outcome. Methods: All primary THA performed with a collarless fully HA-coated stem that had a minimum of 1 year of radiographic follow-up were identified in a surgical database (n = 244). Radiographic measures of proximal femoral morphology and femoral canal fill at the middle and distal thirds of the stem were analysed for association with the presence of proximal radiolucent lines. Linear regression was used to explore any association between radiolucent lines and patient reported outcome measures (PROMs), available in 61% of patients. Results: Proximal radiolucent lines developed in 31 cases (12.7%) at final follow-up. Dorr A femoral morphology and increased canal-fill at the distal 1/3 of the stem correlated with the development of radiolucent lines (p < 0.001). No correlation was observed between pain or PROMs and the presence of proximal radiolucent lines. Discussion: We observed an unexpectedly high incidence of proximal femoral radiolucent lines about collarless fully HA coated stems. Distal-only implant wedging in Dorr A bone may compromise proximal fixation. Although this finding did not correlate with short-term outcomes, the long-term clinical impact requires further study.
引用
下载
收藏
页码:49 / 56
页数:8
相关论文
共 50 条
  • [31] Hydroxyapatite-coated femoral stems in primary total hip arthroplasty: A meta-analysis of randomized controlled trials
    Li, Shuzhen
    Huang, Baohua
    Chen, Yueping
    Gao, Hui
    Fan, Qie
    Zhao, Jinmin
    Su, Wei
    INTERNATIONAL JOURNAL OF SURGERY, 2013, 11 (06) : 477 - 482
  • [32] What Is the Risk of Revision Surgery in Hydroxyapatite-coated Femoral Hip Stems? Findings From a Large National Registry
    Inacio, Maria C.
    Lorimer, Michelle
    Davidson, David C.
    De Steiger, Richard N.
    Lewis, Peter L.
    Graves, Stephen E.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2018, 476 (12) : 2353 - 2366
  • [33] Mid-term progressive loosening of hydroxyapatite-coated femoral stems paired with a metal-on-metal bearing
    Gascoyne, Trevor
    Flynn, Bryan
    Turgeon, Thomas
    Burnell, Colin
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2019, 14 (1)
  • [34] Mid-term progressive loosening of hydroxyapatite-coated femoral stems paired with a metal-on-metal bearing
    Trevor Gascoyne
    Bryan Flynn
    Thomas Turgeon
    Colin Burnell
    Journal of Orthopaedic Surgery and Research, 14
  • [35] Fracture of fully hydroxyapatite-coated titanium femoral stem of a total hip replacement - a report of 3 cases
    Sharma, DK
    Brooks, S
    Creasey, S
    Lewis, B
    ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (06): : 768 - 771
  • [36] Hydroxyapatite-coated versus grit-blasted femoral stems -: A prospective, randomised study using EBRA-FCA
    Hamadouche, M
    Witvoet, J
    Porcher, R
    Meunier, A
    Sedel, L
    Nizard, R
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (07): : 979 - 987
  • [37] A Randomized Trial of Hydroxyapatite-Coated Femoral Stems in Total Hip Arthroplasty A 13-Year Follow-Up
    Camazzola, Dan
    Hammond, Terry
    Gandhi, Rajiv
    Davey, J. Roderick
    JOURNAL OF ARTHROPLASTY, 2009, 24 (01): : 33 - 37
  • [38] Seven-year Results of a Tapered, Titanium, Hydroxyapatite-Coated Cementless Femoral Stem in Primary Total Hip Arthroplasty
    Cho, Jin-Ho
    Garino, Jonathan P.
    Choo, Suk-Kyu
    Han, Kye-Young
    Kim, Jung-Hoon
    Oh, Hyoung-Keun
    CLINICS IN ORTHOPEDIC SURGERY, 2010, 2 (04) : 214 - 220
  • [39] Prospective five-year subsidence analysis of a cementless fully hydroxyapatite-coated femoral hip arthroplasty component
    Clauss, Martin
    Van der Straeten, Catherine
    Goossens, Marc
    HIP INTERNATIONAL, 2014, 24 (01) : 91 - 97
  • [40] Comparison of canal fill and radiolucent line formation between two fully coated, hydroxyapatite tapered stems: a 2-year follow-up after total hip arthroplasty
    Ittai Shichman
    Kyle W. Lawrence
    Emily Berzolla
    Carlos Sandoval Hernandez
    Rani Man-El
    Yaniv Warschawski
    Nimrod Snir
    Ran Schwarzkopf
    Matthew S. Hepinstall
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 6945 - 6954