Impact of processing-latency induced interaural delay and level discrepancy on sensitivity to interaural level differences in cochlear implant users

被引:0
|
作者
Koertje, Monika [1 ]
Stoever, Timo [2 ]
Baumann, Uwe [1 ]
Weissgerber, Tobias [1 ]
机构
[1] Goethe Univ Frankfurt, Univ Hosp Frankfurt, ENT Dept, Audiol Acoust, Theodor Stern Kai 7, D-60590 Frankfurt, Germany
[2] Univ Hosp Frankfurt, Goethe Univ Frankfurt, ENT Dept, Frankfurt, Germany
关键词
Interaural delay; Interaural level difference; Cochlear implant; Single-sided deafness; Sound localization; SOUND SOURCE LOCALIZATION; SPEECH-PERCEPTION; NORMAL-HEARING; TIME; LISTENERS; CUES;
D O I
10.1007/s00405-023-08013-w
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
PurposeThis study investigated whether an interaural delay, e.g. caused by the processing latency of a hearing device, can affect sensitivity to interaural level differences (ILDs) in normal hearing subjects or cochlear implant (CI) users with contralateral normal hearing (SSD-CI).MethodsSensitivity to ILD was measured in 10 SSD-CI subjects and in 24 normal hearing subjects. The stimulus was a noise burst presented via headphones and via a direct cable connection (CI). ILD sensitivity was measured for different interaural delays in the range induced by hearing devices. ILD sensitivity was correlated with results obtained in a sound localization task using seven loudspeakers in the frontal horizontal plane.ResultsIn the normal hearing subjects the sensitivity to interaural level differences deteriorated significantly with increasing interaural delays. In the CI group, no significant effect of interaural delays on ILD sensitivity was found. The NH subjects were significantly more sensitive to ILDs. The mean localization error in the CI group was 10.8 degrees higher than in the normal hearing group. No correlation between sound localization ability and ILD sensitivity was found.ConclusionInteraural delays influence the perception of ILDs. For normal hearing subjects a significant decrement in sensitivity to ILD was measured. The effect could not be confirmed in the tested SSD-CI group, probably due to a small subject group with large variations. The temporal matching of the two sides may be beneficial for ILD processing and thus sound localization for CI patients. However, further studies are needed for verification.
引用
收藏
页码:5241 / 5249
页数:9
相关论文
共 50 条
  • [41] Lateralization of interaural timing differences with multi-electrode stimulation in bilateral cochlear-implant users
    Kan, Alan
    Jones, Heath G.
    Litovsky, Ruth Y.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2016, 140 (05): : EL392 - EL398
  • [42] Perception of Interaural Phase Differences With Envelope and Fine Structure Coding Strategies in Bilateral Cochlear Implant Users
    Zirn, Stefan
    Arndt, Susan
    Aschendorff, Antje
    Laszig, Roland
    Wesarg, Thomas
    TRENDS IN HEARING, 2016, 20
  • [43] Extent of lateralization at large interaural time differences in simulated electric hearing and bilateral cochlear implant users
    Baumgaertel, Regina M.
    Hu, Hongmei
    Kollmeier, Birger
    Dietz, Mathias
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2017, 141 (04): : 2338 - 2352
  • [44] Interaural level difference sensitivity in neonatally deafened rats fitted with bilateral cochlear implants
    Buchholz, Sarah
    Schnupp, Jan W. H.
    Arndt, Susan
    Rosskothen-Kuhl, Nicole
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [45] Sensitivity of the Human Binaural Cortical Steady State Response to Interaural Level Differences
    Massoud, Sarah
    Aiken, Steve J.
    Newman, Aaron J.
    Phillips, Dennis P.
    Bance, Manohar
    EAR AND HEARING, 2011, 32 (01): : 114 - 120
  • [46] Independent or integrated processing of interaural time and level differences in human auditory cortex?
    Altmann, Christian F.
    Terada, Satoshi
    Kashino, Makio
    Goto, Kazuhiro
    Mima, Tatsuya
    Fukuyama, Hidenao
    Furukawa, Shigeto
    HEARING RESEARCH, 2014, 312 : 121 - 127
  • [47] Across-Frequency Processing of Interaural Time and Level Differences in Perceived Lateralization
    Goupell, Matthew J.
    Stakhovskaya, Olga A.
    ACTA ACUSTICA UNITED WITH ACUSTICA, 2018, 104 (05) : 758 - 761
  • [48] THE EFFECT OF INTERAURAL DELAY OF THE MASKER ON MASKING-LEVEL DIFFERENCES IN YOUNG AND OLD ADULTS
    PICHORAFULLER, MK
    SCHNEIDER, BA
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1992, 91 (04): : 2129 - 2135
  • [50] The Relationship Between Interaural Insertion-Depth Differences, Scalar Location, and Interaural Time-Difference Processing in Adult Bilateral Cochlear-Implant Listeners
    Cleary, Miranda
    Bernstein, Joshua G. W.
    Stakhovskaya, Olga A.
    Noble, Jack
    Kolberg, Elizabeth
    Jensen, Kenneth K.
    Hoa, Michael
    Kim, Hung Jeffrey
    Goupell, Matthew J.
    TRENDS IN HEARING, 2022, 26