Extent of lateralization at large interaural time differences in simulated electric hearing and bilateral cochlear implant users

被引:25
|
作者
Baumgaertel, Regina M. [1 ]
Hu, Hongmei
Kollmeier, Birger
Dietz, Mathias [2 ]
机构
[1] Carl von Ossietzky Univ Oldenburg, Med Phys, Oldenburg, Germany
[2] Western Univ, Sch Commun Sci & Disorders, Natl Ctr Audiol, 1201 Western Rd, London, ON, Canada
来源
关键词
PLACE-OF-STIMULATION; SPEECH-INTELLIGIBILITY; LEVEL DIFFERENCES; FINE-STRUCTURE; TEMPORAL DISPARITIES; SOUND LOCALIZATION; SENSITIVITY; ENVELOPE; LISTENERS; NOISE;
D O I
10.1121/1.4979114
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Normal-hearing (NH) listeners are able to localize sound sources with extraordinary accuracy through interaural cues, most importantly interaural time differences (ITDs) in the temporal fine structure. Bilateral cochlear implant (CI) users are also able to localize sound sources, yet generally at lower accuracy than NH listeners. The gap in performance can in part be attributed to current CI systems not faithfully transmitting interaural cues, especially ITDs. With the introduction of binaurally linked CI systems, the presentation of ITD cues for bilateral CI users is foreseeable. The current study therefore investigated extent-of-lateralization percepts elicited in bilateral CI listeners when presented with single-electrode pulse-trains carrying controlled ITD cues. The results were compared against NH listeners listening to broadband stimuli as well as simulations of CI listening. Broadband stimuli in NH listeners were perceived as fully lateralized within the natural ITD range. Using simulated as well as real CI stimuli, however, only a fraction of the full extent of lateralization range was covered by natural ITDs. The maximum extent of lateralization was reached at ITDs as large as twice the natural limit. The results suggest that ITD-enhancement might be a viable option for improving localization abilities with future binaural CI systems. (C) 2017 Acoustical Society of America.
引用
收藏
页码:2338 / 2352
页数:15
相关论文
共 50 条
  • [1] Lateralization of interaural time differences with mixed rates of stimulation in bilateral cochlear implant listeners
    Thakkar, Tanvi
    Kan, Alan
    Litovsky, Ruth Y.
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2023, 153 (03): : 1912 - 1923
  • [2] Lateralization of interaural timing differences with multi-electrode stimulation in bilateral cochlear-implant users
    Kan, Alan
    Jones, Heath G.
    Litovsky, Ruth Y.
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2016, 140 (05): : EL392 - EL398
  • [3] Enhancement of interaural level differences for bilateral cochlear implant users
    Gajecki, Tom
    Nogueira, Waldo
    [J]. HEARING RESEARCH, 2021, 409
  • [4] Sensitivity of bilateral cochlear implant users to fine-structure and envelope interaural time differences
    Noel, Victor A.
    Eddington, Donald K.
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2013, 133 (04): : 2314 - 2328
  • [5] Sensitivity of bilateral cochlear implant users to fine-structure and envelope interaural time differences
    [J]. Noel, V.A. (victor_noel@meei.harvard.edu), 1600, Acoustical Society of America (133):
  • [6] Lateralization of Interaural Level Differences with Multiple Electrode Stimulation in Bilateral Cochlear-Implant Listeners
    Stakhovskaya, Olga A.
    Goupell, Matthew J.
    [J]. EAR AND HEARING, 2017, 38 (01): : E22 - E38
  • [7] Lateralization of interaural level differences in children with bilateral cochlear implants
    Sparreboom, M.
    Ausili, S. A.
    Mylanus, E. A. M.
    [J]. COCHLEAR IMPLANTS INTERNATIONAL, 2022, 23 (03) : 125 - 133
  • [8] The use of interaural time and level difference cues by bilateral cochlear implant users
    Aronoff, Justin M.
    Yoon, Yang-soo
    Freed, Daniel J.
    Vermiglio, Andrew J.
    Pal, Ivan
    Soli, Sigfrid D.
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2010, 127 (03): : EL87 - EL92
  • [9] Sensitivity to interaural time differences and localization accuracy in cochlear implant users with combined electric-acoustic stimulation
    Koertje, Monika
    Baumann, Uwe
    Stoever, Timo
    Weissgerber, Tobias
    [J]. PLOS ONE, 2020, 15 (10):
  • [10] Processing of interaural time differences in normal-hearing subjects and cochlear implant users with FSP and HDCIS coding strategy
    Heidekrueger, N.
    Rahne, T.
    Wagner, L.