Analysis of dual-energy mammography subtraction technique for the dose and image quality evaluation using 3D-printed breast phantom

被引:0
|
作者
Endarko, Fitria M. [1 ]
Celina, Fitria M. [1 ]
Gani, M. Roslan A. [2 ]
机构
[1] Kampus ITS, Lab Med Phys & Biophys, Inst Teknol Sepuluh Nopember, Surabaya 60111, East Java, Indonesia
[2] Dharmais Natl Canc Ctr Hosp, Dept Radiodiagnost, Jakarta, Indonesia
关键词
Mammography; Dual-energy; Doses; Image quality; ENHANCED SPECTRAL MAMMOGRAPHY; DIGITAL MAMMOGRAPHY; DIAGNOSTIC PERFORMANCE; TOMOSYNTHESIS; CESM;
D O I
10.1007/s13246-023-01330-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study aimed to quantitatively assess the radiation dose using XR-QA2 and the image quality of the dual-energy subtraction mammography technique on an in-house phantom. The analysis was carried out to investigate the effect of targets/filters on dose value and image quality using an in-house phantom made of PLA + as an object representing compressed breasts. All irradiation parameters were performed in the craniocaudal position with manual mode. Mean glandular dose (MGD) was recorded, followed by the calculation of the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and modulation transfer function (MTF) for image quality assessment parameters. The results showed that the image quality was accepted at dose levels within the IAEA and BAPETEN tolerance limit for 60 mm equivalent compressed breast using dual-energy mammography. Furthermore, the target/filter (W/Rh) reduced the dose by 1.03 mGy compared to the Mo/Mo and Mo/Rh with an enhancement in image quality. This indicated that the target/filter (W/Rh) combination was optimal due to the image quality improvement obtained with lower MGD.
引用
收藏
页码:1693 / 1701
页数:9
相关论文
共 50 条
  • [31] Technique and clinical applications of dual-energy contrast-enhanced digital mammography (CEDM) in breast cancer evaluation: a pictorial essay
    Sudhir, Rashmi
    Koppula, Veeraiah
    Mandava, Anitha
    Kamala, Sannapareddy
    Potlapalli, Alekya
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2021, 27 (01) : 28 - 36
  • [32] Evaluation of a novel phantom for the quality assurance of a six-degree-of-freedom couch 3D-printed at multiple centres
    Marshall, Hannah
    Selvan, Tamil
    Ahmad, Reem
    Bento, Mariana
    Veiga, Catarina
    Sands, Gordon
    Malone, Ciaran
    King, Raymond B.
    Clark, Catharine H.
    McGarry, Conor K.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 114
  • [33] Evaluation of image quality, radiation dose and diagnostic performance of dual-energy CT datasets in patients with hepatocellular carcinoma
    Anzidei, M.
    Di Martino, M.
    Sacconi, B.
    Saba, L.
    Boni, F.
    Zaccagna, F.
    Geiger, D.
    Kirchin, M. A.
    Napoli, A.
    Bezzi, M.
    Catalano, C.
    CLINICAL RADIOLOGY, 2015, 70 (09) : 966 - 973
  • [34] Contrast-enhanced dual-energy mammography using a scanned multislit system:: evaluation of a differential beam filtering technique
    Bornefalk, Hans
    Hemmendorff, Magnus
    Hjarn, Torbjorn
    JOURNAL OF ELECTRONIC IMAGING, 2007, 16 (02)
  • [35] Development of a cost-effective 3D-printed MRI phantom for enhanced teaching of system performance and image quality concepts
    Yusuff, Habeeb
    Zorn, Pierre-Emmanuel
    Giraudeau, Celine
    Wach, Benoit
    Choquet, Philippe
    Chatelin, Simon
    Dillenseger, Jean-Philippe
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2024,
  • [36] Technical Note: A 3D-printed phantom for radiochromic film evaluation of moving lung tumor SBRT without dose convolution
    Retif, Paul
    Djibo Sidikou, Abdourahamane
    Letellier, Romain
    Verrecchia-Ramos, Emilie
    Quetin, Philippe
    MEDICAL PHYSICS, 2021, 48 (07) : 3453 - 3458
  • [37] Dimensional Accuracy Evaluation of 3D-Printed Parts Using a 3D Scanning Surface Metrology Technique
    Biglete, Emmanuelle R.
    Dela Cruz, Jennifer C.
    Verdadero, Marvin S.
    Manuel, Mark Christian E.
    Altea, Allison R.
    Lubi, Argel Joseph O.
    Gatpayat, Allan Gabriel R.
    Santos, Christian Dale B.
    2020 11TH IEEE CONTROL AND SYSTEM GRADUATE RESEARCH COLLOQUIUM (ICSGRC), 2020, : 185 - 190
  • [38] Low cost multifunctional 3D printed image quality and dose verification phantom for an image-guided radiotherapy system
    Wu, Jian-Kuen
    Yu, Min-Chin
    Chen, Shih-Han
    Liao, Shu-Hsien
    Wang, Yu-Jen
    PLOS ONE, 2022, 17 (04):
  • [39] Initial Results of a Single-Source Dual-Energy Computed Tomography Technique Using a Split-Filter Assessment of Image Quality, Radiation Dose, and Accuracy of Dual-Energy Applications in an In Vitro and In Vivo Study
    Euler, Andre
    Parakh, Anushri
    Falkowski, Anna L.
    Manneck, Sebastian
    Dashti, David
    Krauss, Bernhard
    Szucs-Farkas, Zsolt
    Schindera, Sebastian T.
    INVESTIGATIVE RADIOLOGY, 2016, 51 (08) : 491 - 498
  • [40] Verification of mean dose in a tumor using 3D-printed tumor-model scintillators in anthropomorphic phantoms and a spherical phantom
    Seo, Young Chan
    Kim, Tae Hoon
    Choi, Yona
    Yang, Hye Jeong
    Kim, Yong Kyun
    Kim, Kyo-Tae
    Bahng, Jungbae
    Chung, Hyun-Tai
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2025, 57 (03)