A self-stiffening compliant intracortical microprobe

被引:0
|
作者
Sharafkhani, Naser [1 ]
Long, John M. [1 ]
Adams, Scott D. [1 ]
Kouzani, Abbas Z. [1 ]
机构
[1] Deakin Univ, Sch Engn, Geelong, Vic 3216, Australia
关键词
Intracortical microprobe; Insertion; Buckling; Self-stiffening; Finite element method; 3D printing; NEURAL PROBE; BRAIN-TISSUE;
D O I
10.1007/s10544-024-00700-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Utilising a flexible intracortical microprobe to record/stimulate neurons minimises the incompatibility between the implanted microprobe and the brain, reducing tissue damage due to the brain micromotion. Applying bio-dissolvable coating materials temporarily makes a flexible microprobe stiff to tolerate the penetration force during insertion. However, the inability to adjust the dissolving time after the microprobe contact with the cerebrospinal fluid may lead to inaccuracy in the microprobe positioning. Furthermore, since the dissolving process is irreversible, any subsequent positioning error cannot be corrected by re-stiffening the microprobe. The purpose of this study is to propose an intracortical microprobe that incorporates two compressible structures to make the microprobe both adaptive to the brain during operation and stiff during insertion. Applying a compressive force by an inserter compresses the two compressible structures completely, resulting in increasing the equivalent elastic modulus. Thus, instant switching between stiff and soft modes can be accomplished as many times as necessary to ensure high-accuracy positioning while causing minimal tissue damage. The equivalent elastic modulus of the microprobe during operation is approximate to 23 kPa, which is approximate to 42% less than the existing counterpart, resulting in approximate to 46% less maximum strain generated on the surrounding tissue under brain longitudinal motion. The self-stiffening microprobe and surrounding neural tissue are simulated during insertion and operation to confirm the efficiency of the design. Two-photon polymerisation technology is utilised to 3D print the proposed microprobe, which is experimentally validated and inserted into a lamb's brain without buckling.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Compliant intracortical implants reduce strains and strain rates in brain tissue in vivo
    Sridharan, Arati
    Nguyen, Jessica K.
    Capadona, Jeffrey R.
    Muthuswamy, Jit
    JOURNAL OF NEURAL ENGINEERING, 2015, 12 (03)
  • [22] MACCEPA 2.0: Adjustable Compliant Actuator with Stiffening Characteristic for Energy Efficient Hopping
    Vanderborght, Bram
    Tsagarakis, Nikos G.
    Semini, Claudio
    Van Ham, Ronald
    Caldwell, Darwin G.
    ICRA: 2009 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1-7, 2009, : 179 - +
  • [23] CMOS-BASED HIGH-DENSITY SILICON MICROPROBE FOR STRESS MAPPING IN INTRACORTICAL APPLICATIONS
    Seidl, Karsten
    Lemke, Benjamin
    Ramirez, Hernando
    Herwik, Stanislav
    Ruther, Patrick
    Paul, Oliver
    MEMS 2010: 23RD IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST, 2010, : 35 - 38
  • [24] Self-Reconfiguring and Stiffening Origami Tube
    Suh, Jong-Eun
    Miyazawa, Yasuhiro
    Yang, Jinkyu
    Han, Jae-Hung
    ADVANCED ENGINEERING MATERIALS, 2022, 24 (05)
  • [25] Toward an Energy-Efficient High-Voltage Compliant Visual Intracortical Multichannel Stimulator
    Hasanuzzaman, Md.
    Motlagh, Bahareh G.
    Mounaim, Faycal
    Hassan, Ahmad
    Raut, Rabin
    Sawan, Mohamad
    IEEE TRANSACTIONS ON VERY LARGE SCALE INTEGRATION (VLSI) SYSTEMS, 2018, 26 (05) : 878 - 891
  • [26] Self-locking and stiffening deployable tubular structures
    Lee, Ting-Uei
    Lu, Hongjia
    Ma, Jiaming
    San Ha, Ngoc
    Gattas, Joseph M.
    Xie, Yi Min
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2024, 121 (40)
  • [27] HOW COMPLIANT IS COMPLIANT - EVALUATING ADHERENCE WITH BREAST SELF-EXAM POSITIONS
    STEVENS, VM
    HATCHER, JW
    BRUCE, BK
    JOURNAL OF BEHAVIORAL MEDICINE, 1994, 17 (05) : 523 - 534
  • [28] CMOS-Based High-Density Silicon Microprobe Arrays for Electronic Depth Control in Intracortical Neural Recording
    Seidl, Karsten
    Herwik, Stanislav
    Torfs, Tom
    Neves, Herc P.
    Paul, Oliver
    Ruther, Patrick
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2011, 20 (06) : 1439 - 1448
  • [29] Biomimetic Strain-Stiffening Self-Assembled Hydrogels
    Wang, Yiming
    Xu, Zhi
    Lovrak, Matija
    le Sage, Vincent A. A.
    Zhang, Kai
    Guo, Xuhong
    Eelkema, Rienk
    Mendes, Eduardo
    van Esch, Jan H.
    Angewandte Chemie - International Edition, 2020, 59 (12): : 4830 - 4834
  • [30] Biomimetic Strain-Stiffening Self-Assembled Hydrogels
    Wang, Yiming
    Xu, Zhi
    Lovrak, Matija
    le Sage, Vincent A. A.
    Zhang, Kai
    Guo, Xuhong
    Eelkema, Rienk
    Mendes, Eduardo
    van Esch, Jan H.
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2020, 59 (12) : 4830 - 4834