Reliable Crack Monitoring Based on Guided Wave Through Periodically Loaded Transmission Line

被引:4
|
作者
Zhang, Jun [1 ]
Hu, Wenlong [1 ]
Chen, Zebin [1 ]
Yang, Pengchuan [1 ]
Wang, Kun [1 ]
Xie, Xiangyu [2 ]
Huang, Bei [3 ]
Dong, Lihong [4 ]
Wang, Haidou [4 ,5 ]
机构
[1] Guangdong Univ Technol, Sch Informat Engn, Guangzhou 510006, Peoples R China
[2] Guiyang Univ, Guizhou Prov Coll Based Engn Res Ctr Mat Prot Wea, Guiyang 550005, Peoples R China
[3] Guangdong Polytech Normal Univ, Sch Elect & Informat, Guangzhou 510665, Peoples R China
[4] Army Acad Armored Forces, Natl Key Lab Remfg, Beijing 100072, Peoples R China
[5] Army Acad Armored Forces, Natl Engn Res Ctr Remfg, Beijing 100072, Peoples R China
基金
中国国家自然科学基金;
关键词
Sensors; Sensitivity; Monitoring; Sensor phenomena and characterization; Power transmission lines; Mechanical sensors; Feature extraction; Crack detection; guided wave (GW); periodically loaded transmission line (PLTL); propagation constant; structural health monitoring (SHM); SPLIT-RING RESONATOR; SURFACE CRACKS; SENSOR; PROBE;
D O I
10.1109/JSEN.2023.3242672
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Cracks are commonly occurring defects in metal. Crack monitoring in large-area infrastructures requires numerous sensors and thus increases the weight, complexity, and integrity problem for wire deployment. The electromagnetic (EM) resonator-based sensor enjoys good sensitivity but suffers limited coverage. The perturbation theory governing crack detection for EM resonator-based sensors indicates that the uneven field distribution inside the resonator is the bottleneck behind the sensitivity and coverage. In this article, the EM energy is confined underneath the resonator but evenly distributed along the transmission line through periodically loading interleaved step impedance resonators (SIRs) on the two sides of a microstrip line. In this way, the sensitivity can be maintained and the coverage can be extended. An averaged attenuation constant is studied and extracted as a feature for crack characterization. The measurement normalized sensitivity is -0.057 N.U./mm(2). This article provides a paradigm to bridge the gap between local and global monitoring. The proposed sensor can be used for monitoring potential cracks of in-service complex components.
引用
收藏
页码:6799 / 6809
页数:11
相关论文
共 50 条
  • [21] Periodically loaded transmission line with effective negative refractive index and negative group velocity
    Siddiqui, OF
    Mojahedi, M
    Eleftheriades, GV
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2003, 51 (10) : 2619 - 2625
  • [22] Anomalous reflection and refraction in anisotropic metamaterial realized by periodically loaded transmission line network
    Feng, Yijun
    Teng, Xiaohua
    Zhao, Junming
    Chen, Yan
    Jiang, Tian
    Journal of Applied Physics, 2006, 100 (11):
  • [23] Small-size delay line based on a periodically loaded waveguide
    Hesselbarth, J
    Vahldieck, R
    2001 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM DIGEST, VOLS 1-3, 2001, : 775 - 778
  • [24] Health Monitoring of Plate Structures Based on Tomography With Combination of Guided Wave Transmission and Reflection
    Wang, Zhe
    Han, Te
    Wang, Shen
    Zhan, Zaifu
    Zhao, Wei
    Huang, Songling
    IEEE SENSORS JOURNAL, 2022, 22 (11) : 10850 - 10860
  • [25] Generation of electrical short pulses using a Schottky transmission line periodically loaded with tunnelling diodes
    Essimbi, B. Z.
    Jaeger, D.
    PHYSICA SCRIPTA, 2010, 81 (03)
  • [26] A PZT Based On-Line Updated Guided Wave-Gaussian Process Method for Crack Evaluation
    Yuan, Shenfang
    Wang, Hui
    Chen, Jian
    IEEE SENSORS JOURNAL, 2020, 20 (15) : 8204 - 8212
  • [27] NONLINEAR WAVE PROPAGATION IN A TRANSMISSION LINE LOADED WITH THIN PERMALLOY FILMS
    GUTZWILLER, MC
    MIRANKER, WL
    IBM JOURNAL OF RESEARCH AND DEVELOPMENT, 1963, 7 (04) : 278 - 287
  • [28] Intelligent On-line Monitoring System Based On Elastic Wave For Overhead Transmission Lines
    Guo, Rui
    Zhang, Feng
    Zhong, Liang
    2013 IEEE INTERNATIONAL CONFERENCE ON INFORMATION AND AUTOMATION (ICIA), 2013, : 115 - 118
  • [29] Nonreciprocal Guided Wave Propagation Characteristics of a Thick Metal Strip Periodically Loaded Ferrite Slab Waveguide
    Nishimura, Kazuo
    2016 IEEE ANTENNAS AND PROPAGATION SOCIETY INTERNATIONAL SYMPOSIUM, 2016, : 1965 - 1966
  • [30] Research on Logic Optimization and Reliable Calculation Model of Satellite Based Wildfire Monitoring for Power Transmission Line
    Zhou, Zhenzhen
    Chen, Gang
    2018 2ND INTERNATIONAL CONFERENCE ON POWER AND ENERGY ENGINEERING (ICPEE 2018), 2018, 192