Reliable Crack Monitoring Based on Guided Wave Through Periodically Loaded Transmission Line

被引:4
|
作者
Zhang, Jun [1 ]
Hu, Wenlong [1 ]
Chen, Zebin [1 ]
Yang, Pengchuan [1 ]
Wang, Kun [1 ]
Xie, Xiangyu [2 ]
Huang, Bei [3 ]
Dong, Lihong [4 ]
Wang, Haidou [4 ,5 ]
机构
[1] Guangdong Univ Technol, Sch Informat Engn, Guangzhou 510006, Peoples R China
[2] Guiyang Univ, Guizhou Prov Coll Based Engn Res Ctr Mat Prot Wea, Guiyang 550005, Peoples R China
[3] Guangdong Polytech Normal Univ, Sch Elect & Informat, Guangzhou 510665, Peoples R China
[4] Army Acad Armored Forces, Natl Key Lab Remfg, Beijing 100072, Peoples R China
[5] Army Acad Armored Forces, Natl Engn Res Ctr Remfg, Beijing 100072, Peoples R China
基金
中国国家自然科学基金;
关键词
Sensors; Sensitivity; Monitoring; Sensor phenomena and characterization; Power transmission lines; Mechanical sensors; Feature extraction; Crack detection; guided wave (GW); periodically loaded transmission line (PLTL); propagation constant; structural health monitoring (SHM); SPLIT-RING RESONATOR; SURFACE CRACKS; SENSOR; PROBE;
D O I
10.1109/JSEN.2023.3242672
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Cracks are commonly occurring defects in metal. Crack monitoring in large-area infrastructures requires numerous sensors and thus increases the weight, complexity, and integrity problem for wire deployment. The electromagnetic (EM) resonator-based sensor enjoys good sensitivity but suffers limited coverage. The perturbation theory governing crack detection for EM resonator-based sensors indicates that the uneven field distribution inside the resonator is the bottleneck behind the sensitivity and coverage. In this article, the EM energy is confined underneath the resonator but evenly distributed along the transmission line through periodically loading interleaved step impedance resonators (SIRs) on the two sides of a microstrip line. In this way, the sensitivity can be maintained and the coverage can be extended. An averaged attenuation constant is studied and extracted as a feature for crack characterization. The measurement normalized sensitivity is -0.057 N.U./mm(2). This article provides a paradigm to bridge the gap between local and global monitoring. The proposed sensor can be used for monitoring potential cracks of in-service complex components.
引用
收藏
页码:6799 / 6809
页数:11
相关论文
共 50 条
  • [11] A periodically perturbed coplanar wave guide transmission line leaky wave antenna
    Stevens, Dale
    Subramanyam, Guru
    Koss, Ken
    Casto, Matt
    Neidhard, Robert
    Pasala, Krishna
    Schneider, Steven
    Radcliffe, Joshua
    Griffith, Henry
    2007 IEEE ANTENNAS AND PROPAGATION SOCIETY INTERNATIONAL SYMPOSIUM, VOLS 1-12, 2007, : 447 - +
  • [12] Feasibility of high frequency guided wave crack monitoring
    Travaglini, Christophe
    Bescond, Christophe
    Viens, Martin
    Belanger, Pierre
    STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2017, 16 (04): : 418 - 427
  • [13] Ring-Resonator Loaded Transmission Line for Crack Detection
    Hu, Wenlong
    Cai, Jiahui
    Deng, Yixuan
    Liang, Zexin
    Zhang, Jun
    Wang, Kun
    2022 IEEE MTT-S INTERNATIONAL MICROWAVE WORKSHOP SERIES ON ADVANCED MATERIALS AND PROCESSES FOR RF AND THZ APPLICATIONS, IMWS-AMP, 2022,
  • [14] Exceptional Points of Degeneracy in a Transmission Line Periodically Loaded with Gain and Radiation Loss
    Hafezi, Ehsan
    Abdelshafy, Ahmed F.
    Mealy, Tarek
    Nikzamir, Alireza
    Capolino, Filippo
    2021 UNITED STATES NATIONAL COMMITTEE OF URSI NATIONAL RADIO SCIENCE MEETING (USNC-URSI NRSM), 2021, : 52 - 53
  • [15] Experimental veitification of 2-D periodically loaded transmission line metamaterial
    Liao, HT
    Zhang, YW
    He, L
    Li, HQ
    Chen, H
    2004 4TH INTERNATIONAL CONFERENCE ON MICROWAVE AND MILLIMETER WAVE TECHNOLOGY PROCEEDINGS, 2004, : 503 - 506
  • [16] Inhomogeneous Microwave Lens Based on Periodically Loaded Transmission Lines
    Vehmas, Joni
    Alitalo, Pekka
    Tretyakov, Sergei
    PROGRESS IN ELECTROMAGNETICS RESEARCH-PIER, 2014, 148 : 141 - 150
  • [17] FATIGUE CRACK GROWTH PROGNOSIS WITH THE PARTICLE FILTER AND ON-LINE GUIDED WAVE STRUCTURAL MONITORING DATA
    Chen, Jian
    Yuan, Shenfang
    Qiu, Lei
    Ren, Yuanqiang
    PROCEEDINGS OF ASME 2021 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION (IMECE2021), VOL 13, 2021,
  • [18] Guided-wave defect signal simulation based on transmission line model
    Kwun, Hegeon
    Kim, Sang Y.
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOL 27A AND 27B, 2008, 975 : 163 - 169
  • [19] A periodically loaded transmission line excited by an aperiodic source - A Green's function approach
    Eshrah, Islam A.
    Kishk, Ahmed A.
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2007, 55 (06) : 1118 - 1123
  • [20] Anomalous reflection and refraction in anisotropic metamaterial realized by periodically loaded transmission line network
    Feng, Yijun
    Teng, Xiaohua
    Zhao, Junming
    Chen, Yan
    Jiang, Tian
    JOURNAL OF APPLIED PHYSICS, 2006, 100 (11)