Analytical and Field Investigation of Ethylene Glycol Removal from the Indirect Water Bath Heater of a City Gate Station

被引:1
|
作者
Salehi, Hadi [1 ]
Farzaneh, Amir [1 ]
Esfandyari, Morteza [2 ]
Amiri Delouei, Amin [3 ]
机构
[1] Khorasan Razavi Prov Gas Co, Prod Management, Mashhad, Iran
[2] Univ Bojnord, Dept Chem Engn, Bojnord, Iran
[3] Univ Bojnord, Dept Mech Engn, Bojnord, Iran
关键词
City gate station; Gas heater; Ethylene glycol; Modeling; Heat transfer; GAS; TEMPERATURE; REDUCTION; CGS;
D O I
10.1007/s40997-023-00674-6
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The aim of this study is to conduct an analytical and field investigation into the removal of antifreeze from a city gate station (CGS) at the city's entrance. The heater of the Robatsang CGS (30,000 SCMH) in Iran was considered for this case study. To verify the model, the experimental results for the CGS heater were compared with the results of the modeling, which revealed reasonable agreement. Based on these results, it appears that the temperature of solution in the CGS tank does not decrease more than the inlet gas temperature. Therefore, it is possible to remove ethylene glycol from the solution's bath heater. Considering the large volume of ethylene glycol required in CGS heaters, the result of this research can lead to a significant cost reduction in CGSs.
引用
收藏
页码:501 / 507
页数:7
相关论文
共 37 条
  • [1] Analytical and Field Investigation of Ethylene Glycol Removal from the Indirect Water Bath Heater of a City Gate Station
    Hadi Salehi
    Amir Farzaneh
    Morteza Esfandyari
    Amin Amiri Delouei
    [J]. Iranian Journal of Science and Technology, Transactions of Mechanical Engineering, 2024, 48 : 501 - 507
  • [2] Geometrical optimization of city gate station's water bath indirect heater to minimization of fuel consumption
    Shafiei, Davood
    Mostafavi, Seyed Alireza
    Mehrabadi, Saeid Jafari
    [J]. JOURNAL OF THERMAL ENGINEERING, 2023, 9 (04): : 841 - 860
  • [3] Performance enhancement of water bath heater at natural gas city gate station using twisted tubes
    Soleimani, P.
    Khoshvaght-Aliabadi, M.
    Rashidi, H.
    Bahmanpour, H.
    [J]. CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2020, 28 (01) : 165 - 179
  • [4] Performance enhancement of water bath heater at natural gas city gate station using twisted tubes
    P.Soleimani
    M.Khoshvaght-Aliabadi
    H.Rashidi
    H.Bahmanpour
    [J]. Chinese Journal of Chemical Engineering, 2020, 28 (01) : 165 - 179
  • [5] Experimental study on the effect of copper oxide nanoparticles on thermophysical properties of ethylene glycol–water for using in indirect heater at city gate stations
    A. R. Rahmati
    M. Reiszadeh
    [J]. Journal of Thermal Analysis and Calorimetry, 2019, 135 : 73 - 82
  • [6] Experimental study on the effect of copper oxide nanoparticles on thermophysical properties of ethylene glycol-water for using in indirect heater at city gate stations
    Rahmati, A. R.
    Reiszadeh, M.
    [J]. JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2019, 135 (01) : 73 - 82
  • [7] Thermal modeling of indirect water heater in city gate station of natural gas to evaluate efficiency and fuel consumption
    Mostafavi, Seyed Alireza
    Shirazi, Mohammad
    [J]. ENERGY, 2020, 212
  • [8] Failure analysis of carbon steel components in a water bath heater and the influence of ethylene glycol concentration
    Shabanian, Sadaf
    Ashrafizadeh, Fakhreddin
    Saeidi, Navid
    Ashrafi, Ali
    [J]. ENGINEERING FAILURE ANALYSIS, 2016, 66 : 533 - 543
  • [9] EXPERIMENTAL INVESTIGATION OF THE INCREASING THERMAL EFFICIENCY OF AN INDIRECT WATER BATH HEATER BY USE OF THERMOSYPHON HEAT PIPE
    Rastegar, Saeed
    Kargarsharifabad, Hadi
    Shafii, Mohammad Behshad
    Rahbar, Nader
    [J]. THERMAL SCIENCE, 2020, 24 (06): : 4277 - 4287
  • [10] CFD simulation of water removal from water/ethylene glycol mixtures by pervaporation
    Rezakazemi, Mashallah
    Shahverdi, Mahnaz
    Shirazian, Saeed
    Mohammadi, Toraj
    Pak, Afshin
    [J]. CHEMICAL ENGINEERING JOURNAL, 2011, 168 (01) : 60 - 67