Assessment of needle-tissue force models based on ex vivo measurements

被引:1
|
作者
Traczynski, Marek [1 ]
Patalas, Adam [1 ]
Roslan, Katarzyna [2 ]
Suszynski, Marcin [1 ]
Talar, Rafa l [1 ]
机构
[1] Poznan Univ Tech, Inst Mech Technol, PL-60965 Poznan, Poland
[2] Poznan Univ Med Sci, Dept Orthoped & Pediat Traumatol, PL-61545 Poznan, Poland
关键词
INSERTION; SKIN;
D O I
10.1016/j.jmbbm.2023.106247
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Needle insertion is one of the most common procedures in clinical practice. Existing statistics reveal that success rates of needle insertions can be low, leading to potential complications and patient discomfort. Real-time imaging techniques like ultrasound and X-ray can assist in improving precision, but even experienced practitioners may face challenges in visualizing the needle tip. Researchers have proposed models of force interactions during needle insertions into biological tissue to enhance accuracy. This article presents an evaluation of the forces acting on intravenous needles during insertion into skin. The aim was to explore mathematical models, compare them with data from tests on animal specimens, and select the most suitable model for future research. The experimental setup involved conducting needle insertion tests on animal-originated cadavers, using the Brucker Universal Mechanical Tester device, which measured the force response during vertical movement of the needle. The research was divided into 2 stages. In Stage I, force measurements were recorded for both the insertion and extraction phases of the hypodermic needles. The measurements were conducted for several different needle sizes, speed and insertion angles. In Stage II, five different models were examined to determine how well they matched the experimental data. Based on the analysis of fit quality coefficients, the Gordon's exponential model was identified as the best fit to the measured data. The influence of needle size, insertion angle, and insertion speed on the measured force values was confirmed. Different insertion speeds revealed the viscoelastic properties of the tested samples. The presence of the skin layer affected the puncture force and force values for subsequent layers.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Intraoperative tumor margin assessment using diffuse reflectance spectroscopy: the effect of electrosurgery on tissue discrimination using ex vivo animal tissue models
    Amiri, Sara Azizian
    Van Gent, Carlijn M.
    Dankelman, Jenny
    Hendriks, Benno H. W.
    BIOMEDICAL OPTICS EXPRESS, 2020, 11 (05) : 2402 - 2415
  • [42] TISSUE BANKING AND 3D 'EX VIVO' MODELS FOR PERSONALIZED MEDICINE
    Baatz, J. E.
    Newton, D. A.
    Riemer, E. C.
    Denlinger, C. E.
    Jones, E. E.
    Drake, R. R.
    Spyropoulos, D. D.
    ANTICANCER RESEARCH, 2014, 34 (10) : 6185 - 6185
  • [43] Ex vivo assessment of in vivo DC-targeted antibodies in pre-clinical models
    Huang, Qingrong
    Anandasabapathy, Niroshana
    TUMOR IMMUNOLOGY AND IMMUNOTHERAPY - CELLULAR METHODS, PT B, 2020, 632 : 417 - 430
  • [44] In vivo and ex vivo assessment of the blood brain barrier integrity in different glioblastoma animal models
    Leten, Cindy
    Struys, Tom
    Dresselaers, Tom
    Himmelreich, Uwe
    JOURNAL OF NEURO-ONCOLOGY, 2014, 119 (02) : 297 - 306
  • [45] In vivo and ex vivo assessment of the blood brain barrier integrity in different glioblastoma animal models
    Cindy Leten
    Tom Struys
    Tom Dresselaers
    Uwe Himmelreich
    Journal of Neuro-Oncology, 2014, 119 : 297 - 306
  • [46] Heterogeneous Breast Phantoms based in Real in-vivo and ex-vivo measurements
    Minano-Saravia, Ivana
    Fernandez-Aranzamendi, E.
    Condori-Huayna, Manuel
    Castillo-Aranibar, P.
    San-Roman, E.
    Gonzalez-Posadas, Vicente
    Segovia-Vargas, Daniel
    2023 17TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION, EUCAP, 2023,
  • [47] In vivo and ex vivo needle-based confocal endomicroscopy of intraductal papillary mucinous neoplasm of the pancreas
    Krishna, Somashekar G.
    Swanson, Benjamin
    Conwell, Darwin L.
    Muscarella, Peter, II
    GASTROINTESTINAL ENDOSCOPY, 2015, 82 (03) : 571 - 572
  • [48] Safer trocar insertion for closed laparoscopic access: ex vivo assessment of an improved Veress needle
    Avinoam Nevler
    Gil Har-Zahav
    Danny Rosin
    Mordechai Gutman
    Surgical Endoscopy, 2016, 30 : 779 - 782
  • [49] Ex-vivo assessment of tissue viability using dynamic laser speckle
    Ramirez-Miquet, E. E.
    Romero, L. M. Miquet
    Darias, J. G.
    Martinez-Celori, R. A.
    SPECKLE 2015: VI INTERNATIONAL CONFERENCE ON SPECKLE METROLOGY, 2015, 9660
  • [50] Safer trocar insertion for closed laparoscopic access: ex vivo assessment of an improved Veress needle
    Nevler, Avinoam
    Har-Zahav, Gil
    Rosin, Danny
    Gutman, Mordechai
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2016, 30 (02): : 779 - 782