Assessment of needle-tissue force models based on ex vivo measurements

被引:1
|
作者
Traczynski, Marek [1 ]
Patalas, Adam [1 ]
Roslan, Katarzyna [2 ]
Suszynski, Marcin [1 ]
Talar, Rafa l [1 ]
机构
[1] Poznan Univ Tech, Inst Mech Technol, PL-60965 Poznan, Poland
[2] Poznan Univ Med Sci, Dept Orthoped & Pediat Traumatol, PL-61545 Poznan, Poland
关键词
INSERTION; SKIN;
D O I
10.1016/j.jmbbm.2023.106247
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Needle insertion is one of the most common procedures in clinical practice. Existing statistics reveal that success rates of needle insertions can be low, leading to potential complications and patient discomfort. Real-time imaging techniques like ultrasound and X-ray can assist in improving precision, but even experienced practitioners may face challenges in visualizing the needle tip. Researchers have proposed models of force interactions during needle insertions into biological tissue to enhance accuracy. This article presents an evaluation of the forces acting on intravenous needles during insertion into skin. The aim was to explore mathematical models, compare them with data from tests on animal specimens, and select the most suitable model for future research. The experimental setup involved conducting needle insertion tests on animal-originated cadavers, using the Brucker Universal Mechanical Tester device, which measured the force response during vertical movement of the needle. The research was divided into 2 stages. In Stage I, force measurements were recorded for both the insertion and extraction phases of the hypodermic needles. The measurements were conducted for several different needle sizes, speed and insertion angles. In Stage II, five different models were examined to determine how well they matched the experimental data. Based on the analysis of fit quality coefficients, the Gordon's exponential model was identified as the best fit to the measured data. The influence of needle size, insertion angle, and insertion speed on the measured force values was confirmed. Different insertion speeds revealed the viscoelastic properties of the tested samples. The presence of the skin layer affected the puncture force and force values for subsequent layers.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Powering ex vivo tissue models in microfluidic systems
    McLean, Ian C.
    Schwerdtfeger, Luke A.
    Tobet, Stuart A.
    Henry, Charles S.
    LAB ON A CHIP, 2018, 18 (10) : 1399 - 1410
  • [22] Ex vivo optical metabolic measurements from cultured tissue reflect in vivo tissue status
    Walsh, Alex J.
    Poole, Kristin M.
    Duvall, Craig L.
    Skala, Melissa C.
    JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (11)
  • [23] Assessment of proarrhythmic activity of chloroquine in in vivo and ex vivo rabbit models
    Khobragade, Shailaja B.
    Gupta, Pankaj
    Gurav, Prashant
    Chaudhari, Girish
    Gatne, Madhumanjiri M.
    Shingatgeri, Vyas M.
    JOURNAL OF PHARMACOLOGY & PHARMACOTHERAPEUTICS, 2013, 4 (02) : 116 - 124
  • [24] Urinary Bladder Volume Reconstruction Based on Bioimpedance Measurements: Ex Vivo and In Vivo Validation Through Implanted Patch and Needle Electrodes
    Semproni, Federica
    Iacovacci, Veronica
    Musco, Stefania
    Menciassi, Arianna
    IEEE SENSORS JOURNAL, 2023, 23 (24) : 31287 - 31296
  • [25] CT-based weight assessment of lung lobes: comparison with ex vivo measurements
    Sverzellati, Nicola
    Kuhnigk, Jan-Martin
    Furia, Simone
    Diciotti, Stefano
    Scanagatta, Paolo
    Marchiano, Alfonso
    Molinari, Francesco
    Stoecker, Christina
    Pastorino, Ugo
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2013, 19 (05) : 355 - 359
  • [26] Fastin vivo measurements of local tissue impedances using needle electrodes
    Y. Kinouchi
    T. Iritani
    T. Morimoto
    S. Ohyama
    Medical and Biological Engineering and Computing, 1997, 35 : 486 - 492
  • [27] Fast in vivo measurements of local tissue impedances using needle electrodes
    Kinouchi, Y
    Iritani, T
    Morimoto, T
    Ohyama, S
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1997, 35 (05) : 486 - 492
  • [28] Fast in vivo measurements of local tissue impedances using needle electrodes
    Department of Electrical Engineering, University of Tokushima, Tokushima 770, Japan
    不详
    不详
    MED. BIOL. ENG. COMPUT., 5 (486-492):
  • [29] Miniaturized Force/Torque Sensor for In Vivo Measurements of Tissue Characteristics
    Hessinger, M.
    Pilic, T.
    Werthschuetzky, R.
    Pott, P. P.
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 2022 - 2025
  • [30] Cellular Force Microscopy for in Vivo Measurements of Plant Tissue Mechanics
    Routier-Kierzkowska, Anne-Lise
    Weber, Alain
    Kochova, Petra
    Felekis, Dimitris
    Nelson, Bradley J.
    Kuhlemeier, Cris
    Smith, Richard S.
    PLANT PHYSIOLOGY, 2012, 158 (04) : 1514 - 1522