Photovoltaic capacity dynamic tracking model predictive control strategy of air-conditioning systems with consideration of flexible loads

被引:4
|
作者
Zhao, Jing [1 ]
Yang, Zilan [1 ]
Shi, Linyu [1 ]
Liu, Dehan [1 ]
Li, Haonan [1 ]
Mi, Yumiao [2 ]
Wang, Hongbin [2 ]
Feng, Meili [2 ]
Hutagaol, Timothy Joseph [3 ]
机构
[1] Tianjin Univ, Sch Environm Sci & Engn, Tianjin Key Lab Built Environm & Energy Applicat, Tianjin 300350, Peoples R China
[2] Tianjin Anjie IoT Sci & Technol Co Ltd, Tianjin 300380, Peoples R China
[3] Tianjin Univ, Sch Chem Engn & Technol, State Key Lab Chem Engn, Tianjin 300350, Peoples R China
关键词
Model predictive control; Flexible regulation of HVAC systems; Flexible load; Demand -side management; NEURAL-NETWORK; ENERGY FLEXIBILITY; BUILDINGS; POWER; OPTIMIZATION; PV; ALGORITHM; STORAGE; MPC; ANN;
D O I
10.1016/j.apenergy.2023.122430
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Building photovoltaic (PV) power generation is intermittent, volatile, random, and uncontrollable; thus, the use of solar grid-connected power generation can lead to a series of problems, such as grid voltage fluctuations and power imbalance. As a typical flexible load, the scheduling and regulation of the heating, ventilation, and air conditioning (HVAC) system load can help a grid-connected solar grid achieve balanced and flexible operation. This study proposes a PV capacity dynamic tracking model predictive control strategy for air-conditioning systems with flexible loads. This strategy aims to effectively address the issue of unstable grid-connected output of solar PV systems. In particular, a solar radiation prediction model based on a long short-term memory neural network optimized by the grey wolf optimization algorithm was established, which effectively improved the model prediction accuracy. The cost function of HVAC flexible load control considers the law of solar PV output and the human thermal comfort model. A genetic algorithm (GA) is used to obtain the optimal control parameters for dynamic regulation. The GA was employed to efficiently and effectively optimize the control of flexible HVAC loads, considering the variability of the solar PV output and ensuring human thermal comfort. A dynamic regulation model was developed for a typical office building with a grid-connected solar PV power generation system. TRNSYS was utilized for verification based on the actual measured data and relevant meteorological parameters of the case building. A new evaluation metric, volatility, was proposed to evaluate net load fluctuation. The simulation platform based on the physical building yield results indicated a strong resemblance between the energy consumption curve under the predicted control conditions using the flexible model and the PV generation curve. Additionally, the net load volatility was measured to be 2.63. Compared with the predicted control condition without the flexible model, the net load volatility of the grid was reduced by 47.08%, and the energy-saving rate reached 10.89% in the summer.
引用
收藏
页数:21
相关论文
共 50 条
  • [41] Research and Control Strategy of Air-conditioning Load Model Based on Demand Response
    Gao, Shengyu
    Zhang, Haochen
    Cheng, Lexiang
    Wang, Chun
    Wang, Zizhen
    Lin, Zijie
    2018 2ND IEEE CONFERENCE ON ENERGY INTERNET AND ENERGY SYSTEM INTEGRATION (EI2), 2018, : 851 - 855
  • [42] Uncertainty shift in robust predictive control design for application in CAV air-conditioning systems
    Huang, Gongsheng
    Chow, Tin-Tai
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2011, 32 (04): : 329 - 343
  • [43] Innovative control logics for a rational utilization of electric loads and air-conditioning systems in a residential building
    Graditi, G.
    Ippolito, M. G.
    Lamedica, R.
    Piccolo, A.
    Ruvio, A.
    Santinic, E.
    Siano, P.
    Zizzo, G.
    ENERGY AND BUILDINGS, 2015, 102 : 1 - 17
  • [44] Hybrid Control Strategy for Air-conditioning Loads Participating in Peak Load Reduction Through Wide-range Transport Model
    Yunfeng Ma
    Zengqiang Mi
    Ruifeng Zhang
    Huowen Peng
    Yulong Jia
    Journal of Modern Power Systems and Clean Energy, 2022, 10 (06) : 1542 - 1551
  • [45] Hybrid Control Strategy for Air-conditioning Loads Participating in Peak Load Reduction Through Wide-range Transport Model
    Ma, Yunfeng
    Mi, Zengqiang
    Zhang, Ruifeng
    Peng, Huowen
    Jia, Yulong
    JOURNAL OF MODERN POWER SYSTEMS AND CLEAN ENERGY, 2022, 10 (06) : 1542 - 1551
  • [46] An economic model predictive control-based flexible power point tracking strategy for photovoltaic power generation
    Liu, Xiangjie
    Zhu, Zheng
    Kong, Xiaobing
    Ma, Lele
    Lee, Kwang Y.
    ENERGY, 2023, 283
  • [47] A model-based optimal ventilation control strategy of multi-zone VAV air-conditioning systems
    Xu, Xinhua
    Wang, Shengwei
    Sun, Zhongwei
    Xiao, Fu
    APPLIED THERMAL ENGINEERING, 2009, 29 (01) : 91 - 104
  • [48] A novel dynamic predictive control model for variable air volume air conditioning systems using deep learning
    Lei, Lei
    Li, Zonglin
    JOURNAL OF BUILDING ENGINEERING, 2024, 95
  • [49] A dynamic switching strategy for air-conditioning systems operated in light-thermal-load conditions
    Lin, Jin-Long
    Yeh, T. -J.
    Hwang, Wei-Yang
    APPLIED THERMAL ENGINEERING, 2009, 29 (14-15) : 2832 - 2842
  • [50] A novel machine learning-based model predictive control framework for improving the energy efficiency of air-conditioning systems
    Chen, Sihao
    Ding, Puxian
    Zhou, Guang
    Zhou, Xiaoqing
    Li, Jing
    Wang, Liangzhu
    Wu, Huijun
    Fan, Chengliang
    Li, Jiangbo
    ENERGY AND BUILDINGS, 2023, 294