A novel dynamic predictive control model for variable air volume air conditioning systems using deep learning

被引:0
|
作者
Lei, Lei [1 ,3 ]
Li, Zonglin [2 ]
机构
[1] Zhejiang Sci Tech Univ, Sch Civil Engn & Architecture, Hangzhou 310018, Peoples R China
[2] Guilin Univ Elect Technol, Sch Architecture & Transportat Engn, 1 Jinji Rd, Guilin 541004, Peoples R China
[3] Zhejiang Engn Res Ctr Green & Low Carbon Technol B, Hangzhou 310018, Peoples R China
来源
关键词
Multi-zone building; Indoor temperature and humidity; Deep fuzzy cognitive map; Dynamic predictive control; Air-conditioning system; HEAT-CONDUCTION; HUMIDITY; TEMPERATURE;
D O I
10.1016/j.jobe.2024.110314
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Model-based predictive control has proven effective for managing indoor temperature and humidity in variable air volume (VAV) air conditioning systems. However, delays in temperature and humidity adjustments in response to changes in internal and external environmental conditions can impede high-performance operation. This study introduces a dynamic predictive control model for the multi-zone indoor temperature and humidity of VAV systems, designed to predict and control these parameters in real-time. Utilizing the RC network two-node wall structure method and backward finite difference scheme, a multi-zone building model is developed. Coupled with a deep fuzzy cognitive map (DFCM) for temperature and humidity prediction, and controlled by a PID controller, the model dynamically regulates the opening degrees of terminal air dampers and chilled water valves. Implemented on a networked control platform in a large commercial building, the model consistently maintained indoor temperature and humidity within +0.5 degrees C and +0.1 g/(kg dry air) of the target values under varying conditions, demonstrating substantial improvements in stability and operational efficiency. The research enhances the predictability and control of HVAC systems through advanced algorithmic integration, improving real-time indoor climate management in complex building environments. This method offers a practical improvement in HVAC control technologies, which could be beneficial for applications in commercial building management systems, providing a useful tool for supporting energy efficiency and sustainability in modern infrastructures.
引用
下载
收藏
页数:26
相关论文
共 50 条
  • [1] Dynamic Model-Based Fault Tolerant Control of Variable Air Volume Air Conditioning System
    Talukdar, Atanu
    Patra, Amit
    HVAC&R RESEARCH, 2010, 16 (02): : 233 - 254
  • [2] Optimal Control Strategy for Variable Air Volume Air-Conditioning Systems Using Genetic Algorithms
    Seong, Nam-Chul
    Kim, Jee-Heon
    Choi, Wonchang
    SUSTAINABILITY, 2019, 11 (18)
  • [3] Optimal control of variable air volume air-conditioning system
    Chen, You-Ming
    Liu, Jian
    Cheng, Shi-Bai
    Chan, Wing-Hong
    Qin, Jian-Ying
    Zhou, Qiang
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2013, 40 (06): : 1 - 6
  • [4] CONTROL OF VARIABLE AIR VOLUME SYSTEMS
    JANISSE, NJ
    ASHRAE JOURNAL, 1969, 11 (06): : 70 - &
  • [5] Dual mode control research of variable air volume air conditioning system
    Li, Jiejia
    Sun, Xiaoyu
    BioTechnology: An Indian Journal, 2014, 10 (12) : 6246 - 6252
  • [6] Space temperature control of variable air volume air-conditioning system
    Gao, Jiajia
    Xu, Xinhua
    Huang, Gongsheng
    Huazhong Keji Daxue Xuebao (Ziran Kexue Ban)/Journal of Huazhong University of Science and Technology (Natural Science Edition), 2015, 43 (12): : 86 - 89
  • [7] Dynamic performance of an electronic zone air temperature control loop in a typical variable-air-volume air conditioning system
    Hung, Charles Y.S.
    Lam, H.N.
    Dunn, Alan
    HVAC and R Research, 1999, 5 (04): : 317 - 337
  • [8] Dynamic performance of an electronic zone air temperature control loop in a typical variable-air-volume air conditioning system
    Hung, CYS
    Lam, HN
    Dunn, A
    HVAC&R RESEARCH, 1999, 5 (04): : 317 - 337
  • [9] VARIABLE-AIR-VOLUME AIR-CONDITIONING
    NASENBENY, RJ
    SPECIFYING ENGINEER, 1985, 53 (06): : 117 - 119
  • [10] Variable air volume adjustment in air conditioning fans
    Peng, S.M.
    2001, Science Press (31):