Aptamer-Based Electrochemical Microfluidic Biosensor for the Detection of Cryptosporidium parvum

被引:14
|
作者
Moakhar, Roozbeh Siavash [1 ]
Mahimkar, Rohan [2 ,3 ]
Jahromi, Arash Khorrami [1 ]
Mahshid, Sahar Sadat [4 ]
Mata, Carolina del Real [1 ]
Lu, Yao [1 ]
Camargo, Fabio Vasquez [3 ]
Dixon, Brent [5 ]
Gilleard, John [6 ]
Da Silva, Alexandre J. [7 ]
Ndao, Momar [3 ,8 ]
Mahshid, Sara [1 ,8 ]
机构
[1] McGill Univ, Dept Bioengn, Montreal, PQ H3A 0E9, Canada
[2] McGill Univ, Res Inst, Infect Dis & Immun Global Hlth IDIGH, Hlth Ctr, Montreal, PQ H4A 3J1, Canada
[3] McGill Univ, Hlth Ctr, Natl Reference Ctr Parasitol, Res Inst, Montreal, PQ H4A 3J1, Canada
[4] Sunnybrook Res Inst, Sunnybrook Hlth Sci Ctr, Biol Sci, Toronto, ON M4N 3M5, Canada
[5] Bur Microbial Hazards, Food Directorate, Hlth Canada, Ottawa, ON K1A 0K9, Canada
[6] Univ Calgary, Fac Vet Med, Calgary, AB T2N 1N4, Canada
[7] US FDA, Ctr Food Safety & Appl Nutr, College Pk, MD 20740 USA
[8] McGill Univ, Dept Expt Med, Montreal, PQ H3G 2M1, Canada
基金
加拿大创新基金会; 加拿大自然科学与工程研究理事会;
关键词
gold nano-; microislands; electrochemical biosensor; microfluidic device; aptamer; parasites; C; parvum oocysts; ENHANCED RAMAN-SPECTROSCOPY; SURFACE; APTASENSOR; NANOPARTICLES; GRAPHENE; SENSOR;
D O I
10.1021/acssensors.2c01349
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Cryptosporidium parvum is a high-riskand opportunistic waterborne parasitic pathogen with highly infectiousoocysts that can survive harsh environmental conditions for long periods.Current state-of-the-art methods are limited to lengthy imaging andantibody-based detection techniques that are slow, labor-intensive,and demand trained personnel. Therefore, the development of new sensingplatforms for rapid and accurate identification at the point-of-care(POC) is essential to improve public health. Herein, we propose anovel electrochemical microfluidic aptasensor based on hierarchical3D gold nano-/microislands (NMIs), functionalized with aptamers specificto C. parvum. We used aptamers as robustsynthetic biorecognition elements with a remarkable ability to bindand discriminate among molecules to develop a highly selective biosensor.Also, the 3D gold NMIs feature a large active surface area that provideshigh sensitivity and a low limit of detection (LOD), especially whenthey are combined with aptamers,. The performance of the NMI aptasensorwas assessed by testing the biosensor's ability to detect differentconcentrations of C. parvum oocystsspiked in different sample matrices, i.e., buffer, tap water, andstool, within 40 min detection time. The electrochemical measurementsshowed an acceptable LOD of 5 oocysts mL(-1) in buffermedium, as well as 10 oocysts mL(-1) in stool andtap water media, over a wide linear range of 10-100,000 oocystsmL(-1). Moreover, the NMI aptasensor recognized C. parvum oocysts with high selectivity while exhibitingno significant cross-reactivity to other related coccidian parasites.The specific feasibility of the aptasensor was further demonstratedby the detection of the target C. parvum in patient stool samples. Our assay showed coherent results withmicroscopy and real-time quantitative polymerase chain reaction, achievinghigh sensitivity and specificity with a significant signal difference(p < 0.001). Therefore, the proposed microfluidicelectrochemical biosensor platform could be a stepping stone for thedevelopment of rapid and accurate detection of parasites at the POC.
引用
收藏
页码:2149 / 2158
页数:10
相关论文
共 50 条
  • [41] Rapid nanomolar detection of Δ9-tetrahydrocannabinol in biofluids via electrochemical aptamer-based biosensor
    Xie, Yu
    She, Jin-Ping
    Zheng, Jia-Xing
    Salminen, Kalle
    Sun, Jian-Jun
    [J]. ANALYTICA CHIMICA ACTA, 2024, 1295
  • [42] DNA aptamer-based QDs electrochemiluminescence biosensor for the detection of thrombin
    Huang, Haiping
    Zhu, Jun-Jie
    [J]. BIOSENSORS & BIOELECTRONICS, 2009, 25 (04): : 927 - 930
  • [43] Aptamer-based Field-Effect Biosensor for Tenofovir Detection
    N. Aliakbarinodehi
    P. Jolly
    N. Bhalla
    A. Miodek
    G. De Micheli
    P. Estrela
    S. Carrara
    [J]. Scientific Reports, 7
  • [44] Aptamer-based biosensor arrays for detection and quantification of biological macromolecules
    McCauley, TG
    Hamaguchi, N
    Stanton, M
    [J]. ANALYTICAL BIOCHEMISTRY, 2003, 319 (02) : 244 - 250
  • [45] Aptamer-based Field-Effect Biosensor for Tenofovir Detection
    Aliakbarinodehi, N.
    Jolly, P.
    Bhalla, N.
    Miodek, A.
    De Micheli, G.
    Estrela, P.
    Carrara, S.
    [J]. SCIENTIFIC REPORTS, 2017, 7
  • [46] An aptamer-based biosensor for the detection of lysozyme with gold nanoparticles amplification
    Li, Li-Dong
    Chen, Zheng-Bo
    Zhao, Hong-Tao
    Guo, Lin
    Mu, Xiaojiao
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2010, 149 (01): : 110 - 115
  • [47] An Aptamer-based Fluorescence Biosensor for Insulin Detection Based on Graphene Oxide
    Jiang Li-Ying
    Xiao Xiao-Nan
    Zhou Peng-Lei
    Zhang Pei
    Yan Yan-Xia
    Jiang Su-Xia
    Chen Qing-Hua
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 44 (02) : 310 - 314
  • [48] Current signal amplification strategies in aptamer-based electrochemical biosensor: A review
    He, Lei
    Huang, Rongrong
    Xiao, Pengfeng
    Liu, Yuan
    Jin, Lian
    Liu, Hongna
    Li, Song
    Deng, Yan
    Chen, Zhu
    Li, Zhiyang
    He, Nongyue
    [J]. CHINESE CHEMICAL LETTERS, 2021, 32 (05) : 1593 - 1602
  • [49] Improving accuracy and reliability of an electrochemical impedance spectroscopy aptamer-based biosensor
    de Amorim, Rene Santos
    Serrano, Pablo A.
    Nunes, Gisele E.
    Bechtold, Ivan H.
    [J]. RESULTS IN CHEMISTRY, 2024, 7
  • [50] Aptamer-based microcantilever-array biosensor for profenofos detection
    Li, Chao
    Zhang, Guangping
    Wu, Shangquan
    Zhang, Qingchuan
    [J]. ANALYTICA CHIMICA ACTA, 2018, 1020 : 116 - 122