Improving accuracy and reliability of an electrochemical impedance spectroscopy aptamer-based biosensor

被引:0
|
作者
de Amorim, Rene Santos [1 ]
Serrano, Pablo A. [2 ]
Nunes, Gisele E. [2 ]
Bechtold, Ivan H. [2 ]
机构
[1] Univ Fed Santa Catarina, Dept Quim, BR-88040900 Florianopolis, SC, Brazil
[2] Univ Fed Santa Catarina, Dept Fis, BR-88040900 Florianopolis, SC, Brazil
关键词
WATER; ELECTRODES; PLATINUM; GOLD; INTERROGATION; FERRICYANIDE; BEHAVIOR; SYSTEM;
D O I
10.1016/j.rechem.2024.101488
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Impedance -based biosensors are effective tools for rapid and specific detection. However, they often rely solely on charge transfer resistance as an indicator of surface structural changes upon analyte binding and other valuable data are constantly ignored. In this work we explore different data obtained for a biosensor designed for water toxin (Saxitoxin) detection using electrochemical impedance spectroscopy. Both, the signal gain and the relative standard deviation (RSD) were dependent on the potential applied during the measurement. This indicates that the data reading mode can be modulated to favor either the signal or the deviation. The charge transfer resistance (Rct) values with gain up to 18.0 % were obtained, but with RSD higher than 5.0 %. Impressive 39.3 % of signal gain with negligible RSD was found for the real impedance, which is 2.7 -fold higher the values obtained for conventional Rct analysis. Most of the reasonable signals remain at frequencies above 100 Hz, demonstrating that gain at these frequencies tend to be less dispersive. In addition, the relative standard deviation can be reduced by increasing the concentration of the redox probe. The obtained results highlight the importance of carefully selecting parameters for characterizing the electrochemical behavior of the system to identify the most reliable and informative parameters for detection. This research contributes to broader electrochemistry sensing applications, opening new horizons for improving the accuracy and reliability of electrochemical analysis.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] An aptamer-based biosensor for detection of doxorubicin by electrochemical impedance spectroscopy
    Bahner, Nicole
    Reich, Peggy
    Frense, Dieter
    Menger, Marcus
    Schieke, Katharina
    Beckmann, Dieter
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (05) : 1453 - 1462
  • [2] An aptamer-based biosensor for detection of doxorubicin by electrochemical impedance spectroscopy
    Nicole Bahner
    Peggy Reich
    Dieter Frense
    Marcus Menger
    Katharina Schieke
    Dieter Beckmann
    [J]. Analytical and Bioanalytical Chemistry, 2018, 410 : 1453 - 1462
  • [3] Aptamer-based biosensor for label-free detection of ethanolamine by electrochemical impedance spectroscopy
    Liang, Gang
    Man, Yan
    Jin, Xinxin
    Pan, Ligang
    Liu, Xinhui
    [J]. ANALYTICA CHIMICA ACTA, 2016, 936 : 222 - 228
  • [4] Label-free aptamer-based electrochemical impedance biosensor for 17β-estradiol
    Lin, Zhenyu
    Chen, Lifen
    Zhang, Guiyun
    Liu, Qida
    Qiu, Bin
    Cai, Zongwei
    Chen, Guonan
    [J]. ANALYST, 2012, 137 (04) : 819 - 822
  • [5] Graphene- and aptamer-based electrochemical biosensor
    Xu, Ke
    Meshik, Xenia
    Nichols, Barbara M.
    Zakar, Eugene
    Dutta, Mitra
    Stroscio, Michael A.
    [J]. NANOTECHNOLOGY, 2014, 25 (20)
  • [6] An aptamer-based electrochemical biosensor for the detection of Salmonella
    Ma, Xiaoyuan
    Jiang, Yihui
    Jia, Fei
    Yu, Ye
    Chen, Jie
    Wang, Zhouping
    [J]. JOURNAL OF MICROBIOLOGICAL METHODS, 2014, 98 : 94 - 98
  • [7] Aptamer-based electrochemical biosensor for Botulinum neurotoxin
    Wei, Fang
    Ho, Chih-Ming
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (08) : 1943 - 1948
  • [8] Aptamer-based electrochemical biosensor for Botulinum neurotoxin
    Fang Wei
    Chih-Ming Ho
    [J]. Analytical and Bioanalytical Chemistry, 2009, 393
  • [9] Determination of endotoxin through an aptamer-based impedance biosensor
    Su, Wenqiong
    Lin, Meng
    Lee, Hyuck
    Cho, MiSuk
    Choe, Woo-Seok
    Lee, Youngkwan
    [J]. BIOSENSORS & BIOELECTRONICS, 2012, 32 (01): : 32 - 36
  • [10] Aptamer-Based Biosensor
    Zheng Jing
    He Pingang
    Fang Yuzhi