Graphene- and aptamer-based electrochemical biosensor

被引:37
|
作者
Xu, Ke [1 ]
Meshik, Xenia [2 ]
Nichols, Barbara M. [3 ]
Zakar, Eugene [3 ]
Dutta, Mitra [1 ]
Stroscio, Michael A. [1 ,2 ]
机构
[1] Univ Illinois, Dept Elect & Comp Engn, Chicago, IL 60607 USA
[2] Univ Illinois, Dept Bioengn, Chicago, IL 60607 USA
[3] US Army Res Lab, Sensors & Elect Devices Directorate, Adelphi, MD 20783 USA
关键词
DNA; field effect transistor; graphene; ion detection; thrombin binding aptamer (TBA); LABEL-FREE DETECTION; REAGENTLESS; LEAD(II); SENSOR;
D O I
10.1088/0957-4484/25/20/205501
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
This study investigated the effectiveness of a graphene- and aptamer-based field-effect-transistor-like (FET-like) sensor in detecting lead and potassium ions. The sensor consists of a graphene-covered Si/SiO2 wafer with thrombin binding aptamer (TBA) attached to the graphene layer and terminated by a methylene blue (MB) molecule. K+ and Pb2+ both bind to TBA and cause a conformational change, which results in MB moving closer to the graphene surface and donating an electron. Thus, the abundance of K+ and Pb2+ can be determined by monitoring the current across the source and drain channel. Device transfer curves were obtained with ambipolar field effect observed. Current readings were taken for K+ concentrations of 100 mu M to 50 mM and Pb2+ concentrations of 10 mu M to 10 mM. As expected, I-d decreased as ion concentration increased. In addition, there was a negative shift in V-Dirac in response to increased ion concentration.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] An aptamer-based electrochemical biosensor for the detection of Salmonella
    Ma, Xiaoyuan
    Jiang, Yihui
    Jia, Fei
    Yu, Ye
    Chen, Jie
    Wang, Zhouping
    [J]. JOURNAL OF MICROBIOLOGICAL METHODS, 2014, 98 : 94 - 98
  • [2] Aptamer-based electrochemical biosensor for Botulinum neurotoxin
    Wei, Fang
    Ho, Chih-Ming
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (08) : 1943 - 1948
  • [3] Aptamer-based electrochemical biosensor for Botulinum neurotoxin
    Fang Wei
    Chih-Ming Ho
    [J]. Analytical and Bioanalytical Chemistry, 2009, 393
  • [4] Aptamer-Based Biosensor
    Zheng Jing
    He Pingang
    Fang Yuzhi
    [J]. PROGRESS IN CHEMISTRY, 2009, 21 (04) : 732 - 738
  • [5] Aptamer-Based Electrochemical Biosensor for Interferon Gamma Detection
    Liu, Ying
    Tuleouva, Nazgul
    Ramanculov, Erlan
    Revzin, Alexander
    [J]. ANALYTICAL CHEMISTRY, 2010, 82 (19) : 8131 - 8136
  • [6] Aptamer-based biosensor for the electrochemical detection of arsenite in water
    Fuentes, Nicole Rivera
    Vega-Figueroa, Karlene
    Tato, Perla Cruz
    Nicolau, Eduardo
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 255
  • [7] An Aptamer-based Fluorescence Biosensor for Insulin Detection Based on Graphene Oxide
    Jiang Li-Ying
    Xiao Xiao-Nan
    Zhou Peng-Lei
    Zhang Pei
    Yan Yan-Xia
    Jiang Su-Xia
    Chen Qing-Hua
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 44 (02) : 310 - 314
  • [8] An RNA aptamer-based electrochemical biosensor for detection of theophylline in serum
    Ferapontova, Elena E.
    Olsen, Eva M.
    Gothelf, Kurt V.
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2008, 130 (13) : 4256 - +
  • [9] An aptamer-based biosensor for detection of doxorubicin by electrochemical impedance spectroscopy
    Nicole Bahner
    Peggy Reich
    Dieter Frense
    Marcus Menger
    Katharina Schieke
    Dieter Beckmann
    [J]. Analytical and Bioanalytical Chemistry, 2018, 410 : 1453 - 1462
  • [10] Aptamer-based competitive electrochemical biosensor for brevetoxin-2
    Eissa, Shimaa
    Siaj, Mohamed
    Zourob, Mohammed
    [J]. BIOSENSORS & BIOELECTRONICS, 2015, 69 : 148 - 154