MRI parameters for predicting the effect of ultrasound-guided high-intensity focused ultrasound in the ablation of uterine fibroids

被引:9
|
作者
Liao, L. [1 ,5 ]
Xu, Y. H. [2 ]
Bai, J. [3 ]
Zhan, P. [4 ]
Zhou, J. [1 ]
Li, M. X. [1 ]
Zhang, Y. [1 ]
机构
[1] Southwest Med Univ, Affiliated Hosp, Dept Ultrasound, Luzhou 646000, Peoples R China
[2] Fudan Univ Xuhui Branch, Zhongshan Hosp, Dept Med Imaging, Shanghai 200000, Peoples R China
[3] Southwest Med Univ, Affiliated Hosp, Dept Radiol, Luzhou 646000, Peoples R China
[4] Southwest Med Univ, Affiliated Hosp, Dept Gynaecol, Luzhou 646000, Peoples R China
[5] Southwest Med Univ, Affiliated Hosp, Dept Ultrasound, 25 Taiping St, Luzhou 646000, Peoples R China
关键词
LEIOMYOMA RECURRENCE; EMBOLIZATION; PERFUSION;
D O I
10.1016/j.crad.2022.09.112
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To study the value of magnetic resonance imaging (MRI) parameters in predicting the efficacy of ultrasonic ablation of fibroids.MATERIALS AND METHODS: A total of 91 patients were divided into groups based on non-perfused volume (NPV) ratio and blood supply type. The preoperative MRI parameters were measured and analysed. A correlation analysis between the MRI parameters and the NPV ratio was performed. Receiver operating characteristic (ROC) curves were used to analyse and determine the cut-off value of MRI parameters to predict the ablation rate of fibroids.RESULTS: The uterine fibroids group with an NPV ratio <80% and the group with an NPV ratio of >80% had significant differences in signal intensity (SI) at MRI T2-weighted imaging (WI), fibroid-to-rectus abdominis SI ratio (SIR) at T2WI, and blood supply type (p<0.05). There were no significant differences in fibroid volume, T2WI signal uniformity, and apparent diffusion coefficient (ADC) values. The ADC value and SI and SIR at MRI T2WI in the group with poor blood supply were lower than those in the group with a rich blood supply (p<0.05). SI at MRI T2WI correlated negatively with the NPV ratio. The cut-off values for SI and SIR at MRI T2WI of fibroids whose NPV ratio exceeds 80% were 220.58 and 1.315, respectively.CONCLUSION: SI at MRI T2WI and blood supply type could be predictors of the efficacy of ablation. Ultrasonic ablation of fibroids with MRI T2WI hyperintensity and a rich blood supply had poor efficacy.(c) 2022 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:61 / 69
页数:9
相关论文
共 50 条
  • [41] Efficacy and safety of ultrasound-guided high intensity focused ultrasound ablation of symptomatic uterine fibroids in Black women: a preliminary study
    Zhang, C.
    Jacobson, H.
    Ngobese, Z. E.
    Setzen, R.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2017, 124 : 12 - 17
  • [42] Factors influencing magnetic resonance imaging finding of endopelvic fascial edema after ultrasound-guided high-intensity focused ultrasound ablation of uterine fibroids
    Liu, Yuhang
    Liu, Yang
    Lv, Fajin
    Zhong, Yuqing
    Xiao, Zhibo
    Lv, Furong
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2022, 39 (01) : 1088 - 1096
  • [43] Ablation of symptomatic uterine fibroids with the Mirabilis system for rapid noninvasive ultrasound-guided high-intensity focused ultrasound (HIFU): a prospective observational clinical study
    Tonguc, Tolga
    Savchenko, Oleksandr
    Ramig, Olga
    Stader, Judith M.
    Kiessling, Franziska
    Kueppers, Jim
    Egger, Eva K.
    Thudium, Marcus
    Martin, Patrick
    Poll, Wayne
    Schild, Hans H.
    Conrad, Rupert
    Essler, Markus
    Mustea, Alexander
    Strunk, Holger M.
    Marinova, Milka
    RADIOLOGIA MEDICA, 2025,
  • [44] Magnetic resonance imaging parameters in predicting the ablative efficiency of high-intensity focused ultrasound for uterine fibroids
    Gong, Chunmei
    Lin, Zhenjiang
    Lv, Fajin
    Zhang, Lian
    Wang, Zhibiao
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2021, 38 (01) : 523 - 531
  • [45] Effect of "T2-rim sign" related parameters on high-intensity focused ultrasound ablation of uterine fibroids
    Wang, Lu
    Liu, Yang
    Lin, Jinfeng
    Deng, Jinghe
    Yang, Mengchu
    Lv, Fajin
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 181
  • [46] Ultrasound-guided high-intensity Ultrasound Therapy for Fibroids - Pilot Study
    不详
    GYNAKOLOGE, 2018, 51 (11): : 918 - 918
  • [47] Extracorporeal ablation of uterine fibroids with high-intensity focused ultrasound - Imaging and histopathologic evaluation
    Ren, Xiao-Long
    Zhou, Xiao-Dong
    Zhang, Jun
    He, Guang-Bin
    Han, Zeng-Hui
    Zheng, Min-Juan
    Li, Li
    Yu, Ming
    Wang, Lei
    JOURNAL OF ULTRASOUND IN MEDICINE, 2007, 26 (02) : 201 - 212
  • [48] A feasibility analysis of the ArcBlate MR-guided high-intensity focused ultrasound system for the ablation of uterine fibroids
    Chin-Jung Wang
    Gigin Lin
    Yi-Ting Huang
    Cindy Hsuan Weng
    Kai-Yun Wu
    Yu-Ying Su
    Yu-Shan Lin
    Kit-Sum Mak
    Abdominal Radiology, 2021, 46 : 5307 - 5315
  • [49] A feasibility analysis of the ArcBlate MR-guided high-intensity focused ultrasound system for the ablation of uterine fibroids
    Wang, Chin-Jung
    Lin, Gigin
    Huang, Yi-Ting
    Weng, Cindy Hsuan
    Wu, Kai-Yun
    Su, Yu-Ying
    Lin, Yu-Shan
    Mak, Kit-Sum
    ABDOMINAL RADIOLOGY, 2021, 46 (11) : 5307 - 5315
  • [50] Ultrasound-Guided High-Intensity Focused Ultrasound vs Laparoscopic Myomectomy for Symptomatic Uterine Myomas
    Wang, Fulan
    Tang, Liangdan
    Wang, Li
    Wang, Xiaoyan
    Chen, Jinyun
    Liu, Xiaohua
    Gong, Yao
    JOURNAL OF MINIMALLY INVASIVE GYNECOLOGY, 2014, 21 (02) : 279 - 284