MRI parameters for predicting the effect of ultrasound-guided high-intensity focused ultrasound in the ablation of uterine fibroids

被引:9
|
作者
Liao, L. [1 ,5 ]
Xu, Y. H. [2 ]
Bai, J. [3 ]
Zhan, P. [4 ]
Zhou, J. [1 ]
Li, M. X. [1 ]
Zhang, Y. [1 ]
机构
[1] Southwest Med Univ, Affiliated Hosp, Dept Ultrasound, Luzhou 646000, Peoples R China
[2] Fudan Univ Xuhui Branch, Zhongshan Hosp, Dept Med Imaging, Shanghai 200000, Peoples R China
[3] Southwest Med Univ, Affiliated Hosp, Dept Radiol, Luzhou 646000, Peoples R China
[4] Southwest Med Univ, Affiliated Hosp, Dept Gynaecol, Luzhou 646000, Peoples R China
[5] Southwest Med Univ, Affiliated Hosp, Dept Ultrasound, 25 Taiping St, Luzhou 646000, Peoples R China
关键词
LEIOMYOMA RECURRENCE; EMBOLIZATION; PERFUSION;
D O I
10.1016/j.crad.2022.09.112
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To study the value of magnetic resonance imaging (MRI) parameters in predicting the efficacy of ultrasonic ablation of fibroids.MATERIALS AND METHODS: A total of 91 patients were divided into groups based on non-perfused volume (NPV) ratio and blood supply type. The preoperative MRI parameters were measured and analysed. A correlation analysis between the MRI parameters and the NPV ratio was performed. Receiver operating characteristic (ROC) curves were used to analyse and determine the cut-off value of MRI parameters to predict the ablation rate of fibroids.RESULTS: The uterine fibroids group with an NPV ratio <80% and the group with an NPV ratio of >80% had significant differences in signal intensity (SI) at MRI T2-weighted imaging (WI), fibroid-to-rectus abdominis SI ratio (SIR) at T2WI, and blood supply type (p<0.05). There were no significant differences in fibroid volume, T2WI signal uniformity, and apparent diffusion coefficient (ADC) values. The ADC value and SI and SIR at MRI T2WI in the group with poor blood supply were lower than those in the group with a rich blood supply (p<0.05). SI at MRI T2WI correlated negatively with the NPV ratio. The cut-off values for SI and SIR at MRI T2WI of fibroids whose NPV ratio exceeds 80% were 220.58 and 1.315, respectively.CONCLUSION: SI at MRI T2WI and blood supply type could be predictors of the efficacy of ablation. Ultrasonic ablation of fibroids with MRI T2WI hyperintensity and a rich blood supply had poor efficacy.(c) 2022 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:61 / 69
页数:9
相关论文
共 50 条
  • [11] Vaginal delivery outcomes of pregnancies following ultrasound-guided high-intensity focused ultrasound ablation treatment for uterine fibroids
    Liu, Xin
    Xue, Lijuan
    Wang, Yang
    Wang, Wei
    Tang, Jie
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2019, 35 (01) : 510 - 517
  • [12] High-Intensity Focused Ultrasound Ablation of Uterine Fibroids: A Review
    Patel, Nainita
    Chaudhari, Kamlesh
    Patel, Dharmesh
    Joshi, Jalormy
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (09)
  • [13] Extracorporeal ablation of uterine fibroids with high-intensity focused ultrasound
    Mahajan, Niraj N.
    Gaikwad, Nilima L.
    Soni, Rajani N.
    Mahajan, Kshitija N.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2007, 26 (05) : 702 - 702
  • [14] Ultrasound-guided high-intensity focused ultrasound ablation for treating uterine arteriovenous malformation
    Yan, X.
    Zhao, C.
    Tian, C.
    Wen, S.
    He, X.
    Zhou, Y.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2017, 124 : 93 - 96
  • [15] Non-contrast enhanced MRI for assessment of uterine fibroids' early response to ultrasound-guided high-intensity focused ultrasound thermal ablation
    Liao, Dongfang
    Xiao, Zhibo
    Lv, Furong
    Chen, Jinyun
    Qiu, Lanyu
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 122
  • [16] Intraprocedure contrast enhanced ultrasound: The value in assessing the effect of ultrasound-guided high intensity focused ultrasound ablation for uterine fibroids
    Peng, Song
    Hu, Liang
    Chen, Wenzhi
    Chen, Jinyun
    Yang, Caiyong
    Wang, Xi
    Zhang, Rong
    Wang, Zhibiao
    Zhang, Lian
    ULTRASONICS, 2015, 58 : 123 - 128
  • [17] Ovarian Reserve After Ultrasound-Guided High-Intensity Focused Ultrasound for Uterine Fibroids: Preliminary Experience
    Cheung, Vincent Y. T.
    Lam, Tina P. W.
    Jenkins, Caroline R.
    Cheung, Grace K. I.
    Chan, Selina S. Y.
    Choi, W. K.
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY CANADA, 2016, 38 (04) : 357 - 361
  • [18] Techniques to Expand Patient Selection for MRI-Guided High-Intensity Focused Ultrasound Ablation of Uterine Fibroids
    Kim, Young-Sun
    Bae, Duk-Soo
    Park, Min Jung
    Viitala, Antti
    Keserci, Bilgin
    Rhim, Hyunchul
    Lim, Hyo Keun
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 202 (02) : 443 - 451
  • [19] Ultrasound-guided high-intensity focused ultrasound ablation for uterine arteriovenous fistula: a case series
    Li, Fang
    Tao, Hua
    Chen, Jing
    Wang, Li
    Wei, Yini
    Wu, Xiajuan
    Zhang, Yu
    Zeng, Dingyuan
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2024, 41 (01)
  • [20] Clinical application of high-intensity focused ultrasound ablation for uterine fibroids
    Kim Y.-S.
    Biomedical Engineering Letters, 2017, 7 (02) : 99 - 105