Implementation of Individualized Low-Dose Computed Tomography-Guided Hook Wire Localization of Pulmonary Nodules: Feasibility and Safety in the Clinical Setting

被引:2
|
作者
Wei, Wei [1 ]
Wang, Shi-Geng [1 ]
Zhang, Jing-Yi [1 ]
Togn, Xiao-Yu [1 ]
Li, Bei-Bei [1 ]
Fang, Xin [1 ]
Pu, Ren-Wang [1 ]
Zhou, Yu-Jing [1 ]
Liu, Yi-Jun [1 ]
机构
[1] Dalian Med Univ, Affiliated Hosp 1, Dept Radiol, Dalian 116011, Peoples R China
关键词
hook wire; pulmonary nodules; radiation dosage; tomography; X-ray computed; ITERATIVE RECONSTRUCTION; NEEDLE-BIOPSY; CHEST CT; GUIDELINES; REDUCTION; EFFICACY; PROTOCOL;
D O I
10.3390/diagnostics13203235
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: CT-guided hook-wire localization is an essential step in the management of small pulmonary nodules. Few studies, however, have focused on reducing radiation exposure during the procedure. Purpose: This study aims to explore the feasibility of implementing a low-dose computed tomography (CT)-guided hook wire localization using tailored kVp based on patients' body size. Materials and Methods: A total of 151 patients with small pulmonary nodules were prospectively enrolled for CT-guided hook wire localization using individualized low-dose CT (LDCT) vs. standard-dose CT (SDCT) protocols. Radiation dose, image quality, characteristics of target nodules and procedure-related variables were compared. All variables were analyzed using Chi-Square and Student's t-test. Results: The mean CTDIvol was significantly reduced for LDCT (for BMI <= 21 kg/m(2), 0.56 +/- 0.00 mGy and for BMI > 21 kg/m(2), 1.48 +/- 0.00 mGy) when compared with SDCT (for BMI <= 21 kg/m(2), 5.24 +/- 0.95 mGy and for BMI > 21 kg/m(2), 6.69 +/- 1.47 mGy). Accordingly, the DLP of LDCT was significantly reduced as compared with that of SDCT (for BMI <= 21 kg/m(2), 56.86 +/- 4.73 vs. 533.58 +/- 122.06 mGy.cm, and for BMI > 21 kg/m(2), 167.02 +/- 38.76 vs. 746.01 +/- 230.91 mGy.cm). In comparison with SDCT, the effective dose (ED) of LDCT decreased by an average of 89.42% (for BMI <= 21 kg/m(2)) and 77.68% (for BMI > 21 kg/m(2)), respectively. Although the images acquired with the LDCT protocol yielded inferior quality to those acquired with the SDCT protocol, they were clinically acceptable for hook wire localization. Conclusions: LDCT-guided localization can provide safety and nodule detection performance comparable to SDCT-guided localization, benefiting radiation dose reduction dramatically, especially for patients with small body mass indexes.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Computed tomography-guided patent blue vital dye localization of pulmonary nodules in uniportal thoracoscopy
    Lin, Mong-Wei
    Tseng, Yao-Hui
    Lee, Yee-Fan
    Hsieh, Min-Shu
    Ko, Wei-Chun
    Chen, Jo-Yu
    Hsu, Hsao-Hsun
    Chang, Yeun-Chung
    Chen, Jin-Shing
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2016, 152 (02): : 535 - +
  • [42] Preoperative computed tomography-guided localization for multiple pulmonary nodules: comparison of methylene blue and coil
    Sheng-Feng Zhang
    Hai-Ri Liu
    Ai-Li Ma
    Er-Liang Li
    Journal of Cardiothoracic Surgery, 17
  • [43] Preoperative computed tomography-guided localization for multiple pulmonary nodules: comparison of methylene blue and coil
    Zhang, Sheng-Feng
    Liu, Hai-Ri
    Ma, Ai-Li
    Li, Er-Liang
    JOURNAL OF CARDIOTHORACIC SURGERY, 2022, 17 (01)
  • [44] The effectiveness and safety of computed tomography-guided hook-wire localization for secondary video-assisted thoracoscopic surgery: a retrospective study
    Xia, Tian
    Zhou, Ziyue
    Fang, Ziyao
    Xie, Zhuolin
    Shen, Ziqing
    Ding, Cheng
    Huang, Haitong
    Zhang, Yicheng
    Pan, Shu
    Zhao, Jun
    JOURNAL OF THORACIC DISEASE, 2024, 16 (12) : 8350 - 8362
  • [45] Comparison of safety and anxiety/depression in computed tomography-guided hook-wire localization versus electromagnetic navigation bronchoscopy-guided localization: a retrospective cohort study
    Xia, Tian
    Li, Yongsen
    Shen, Ziqing
    Fang, Ziyao
    Chen, Jun
    Pan, Shu
    Feng, Kunpeng
    Huang, Jing
    Ding, Cheng
    Zhao, Jun
    JOURNAL OF THORACIC DISEASE, 2024, 16 (01) : 401 - 413
  • [46] Preoperative computed tomography-guided localization for pulmonary nodules: a randomized controlled trial of coil and anchored needle localization
    Lv, Ya-Nan
    Zhang, Wen -Tao
    Wang, Ying
    Wang, Gang
    VIDEOSURGERY AND OTHER MINIINVASIVE TECHNIQUES, 2024, 19 (02) : 178 - 186
  • [47] Preoperative computed tomography-guided patent blue localization for pulmonary nodules: A single-center experience
    Chang, Po-Chih
    Chou, Shah-Hwa
    Chuang, Che-Yu
    Yang, I-Hsiao
    Liu, Yu-Wei
    Shi, Ming-Cheng
    Sheu, Reu-Sheng
    Chang, Ting-Wei
    FORMOSAN JOURNAL OF SURGERY, 2022, 55 (03) : 102 - 108
  • [48] Consistency of radiologists in identifying pulmonary nodules based on low-dose computed tomography
    Ming, Shuai
    Yang, Wei
    Cui, Si-Jia
    Huang, Shuai
    Gong, Xiang-Yang
    JOURNAL OF THORACIC DISEASE, 2019, 11 (07) : 2973 - 2980
  • [49] Preoperative CT-guided localization of pulmonary nodules with low-dose radiation
    Ma, Yanhe
    Cheng, Shizhao
    Li, Jianhui
    Yuan, Wei
    Song, Zhenchun
    Zhang, Hong
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (07) : 4295 - 4304
  • [50] Systemic air embolism after computed tomography-guided hook wire localization: two case reports and literature review
    Yi, Jung Hoon
    Choi, Pil Jo
    Bang, Jung Hee
    Jeong, Sang Seok
    Cho, Joo Hyun