Implementation of Individualized Low-Dose Computed Tomography-Guided Hook Wire Localization of Pulmonary Nodules: Feasibility and Safety in the Clinical Setting

被引:2
|
作者
Wei, Wei [1 ]
Wang, Shi-Geng [1 ]
Zhang, Jing-Yi [1 ]
Togn, Xiao-Yu [1 ]
Li, Bei-Bei [1 ]
Fang, Xin [1 ]
Pu, Ren-Wang [1 ]
Zhou, Yu-Jing [1 ]
Liu, Yi-Jun [1 ]
机构
[1] Dalian Med Univ, Affiliated Hosp 1, Dept Radiol, Dalian 116011, Peoples R China
关键词
hook wire; pulmonary nodules; radiation dosage; tomography; X-ray computed; ITERATIVE RECONSTRUCTION; NEEDLE-BIOPSY; CHEST CT; GUIDELINES; REDUCTION; EFFICACY; PROTOCOL;
D O I
10.3390/diagnostics13203235
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: CT-guided hook-wire localization is an essential step in the management of small pulmonary nodules. Few studies, however, have focused on reducing radiation exposure during the procedure. Purpose: This study aims to explore the feasibility of implementing a low-dose computed tomography (CT)-guided hook wire localization using tailored kVp based on patients' body size. Materials and Methods: A total of 151 patients with small pulmonary nodules were prospectively enrolled for CT-guided hook wire localization using individualized low-dose CT (LDCT) vs. standard-dose CT (SDCT) protocols. Radiation dose, image quality, characteristics of target nodules and procedure-related variables were compared. All variables were analyzed using Chi-Square and Student's t-test. Results: The mean CTDIvol was significantly reduced for LDCT (for BMI <= 21 kg/m(2), 0.56 +/- 0.00 mGy and for BMI > 21 kg/m(2), 1.48 +/- 0.00 mGy) when compared with SDCT (for BMI <= 21 kg/m(2), 5.24 +/- 0.95 mGy and for BMI > 21 kg/m(2), 6.69 +/- 1.47 mGy). Accordingly, the DLP of LDCT was significantly reduced as compared with that of SDCT (for BMI <= 21 kg/m(2), 56.86 +/- 4.73 vs. 533.58 +/- 122.06 mGy.cm, and for BMI > 21 kg/m(2), 167.02 +/- 38.76 vs. 746.01 +/- 230.91 mGy.cm). In comparison with SDCT, the effective dose (ED) of LDCT decreased by an average of 89.42% (for BMI <= 21 kg/m(2)) and 77.68% (for BMI > 21 kg/m(2)), respectively. Although the images acquired with the LDCT protocol yielded inferior quality to those acquired with the SDCT protocol, they were clinically acceptable for hook wire localization. Conclusions: LDCT-guided localization can provide safety and nodule detection performance comparable to SDCT-guided localization, benefiting radiation dose reduction dramatically, especially for patients with small body mass indexes.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] A hook wire dislodged into the subglottic area as a rare complication following computed tomography-guided hook wire localization: a case report
    Fan, Haiyin
    Guo, Changying
    Zou, Bin
    BMC PULMONARY MEDICINE, 2022, 22 (01)
  • [32] A hook wire dislodged into the subglottic area as a rare complication following computed tomography-guided hook wire localization: a case report
    Haiyin Fan
    Changying Guo
    Bin Zou
    BMC Pulmonary Medicine, 22
  • [33] Factors influencing the accuracy and safety of preoperative computed tomography (CT)-guided soft hook-wire localization for pulmonary nodules: a comprehensive analysis
    Feng, Qianqian
    Zhou, Jin
    Dong, Ningyu
    Chang, Le
    Kong, Weidong
    Rong, Ping
    Chen, Wenqian
    Ma, Yiming
    Zhang, Xin
    Xin, Xiaoyan
    Han, Xiaowei
    Zhang, Bing
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (03) : 2309 - 2320
  • [34] Computed tomography-guided core needle biopsy for lung nodules: low-dose versus standard-dose protocols
    Huang, Yi-Yang
    Cheng, Hong
    Li, Guang-Chao
    VIDEOSURGERY AND OTHER MINIINVASIVE TECHNIQUES, 2021, 16 (02) : 355 - 361
  • [35] Computed tomography-guided dye localization for deeply situated pulmonary nodules in thoracoscopic surgery
    Tsai, Tung-Ming
    Chiang, Xu-Heng
    Liao, Hsien-Chi
    Tsou, Kuan-Chuan
    Lin, Mong-Wei
    Chen, Ke-Cheng
    Hsu, Hsao-Hsun
    Chen, Jin-Shing
    ANNALS OF TRANSLATIONAL MEDICINE, 2019, 7 (02)
  • [36] Cerebral arterial air embolism after computed tomography-guided hook-wire localization of a pulmonary nodule A case report
    Wang, Ming-Yi
    Liu, Yong-Sheng
    An, Xiang-Bo
    Li, Ke
    Liu, Yong-Jian
    Wang, Feng
    MEDICINE, 2019, 98 (18)
  • [37] Efficacy and feasibility of a novel and noninvasive computed tomography-guided marking technique for peripheral pulmonary nodules
    Matsuura, Yosuke
    Mun, Mingyon
    Nakagawa, Ken
    Okumura, Sakae
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2015, 149 (04): : 1208 - 1209
  • [38] Computed tomography-guided cutting needle biopsy for lung nodules A comparative study between low-dose and standard dose protocols
    Zhang, Hui-Mei
    Huo, Xiao-Bing
    Wang, Hua-Long
    Zhang, Xiao
    Fu, Yu-Fei
    MEDICINE, 2021, 100 (03) : E24001
  • [39] Computed tomography-guided localization of small lung nodules before video-assisted resection: Experience with an efficient hook-wire system
    Wicky, S
    Dusmet, M
    Doenz, F
    Ris, HB
    Schnyder, P
    Portier, F
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 124 (02): : 401 - 403
  • [40] Computed Tomography-guided Techniques for Localizing Pulmonary Nodules by Localization Needle versus Methylene Blue
    Zhang, Hua
    Kong, Jian
    Guo, Jian-Xi
    CURRENT MEDICAL IMAGING, 2023, 19 (07) : 770 - 779