Implementation of Individualized Low-Dose Computed Tomography-Guided Hook Wire Localization of Pulmonary Nodules: Feasibility and Safety in the Clinical Setting

被引:2
|
作者
Wei, Wei [1 ]
Wang, Shi-Geng [1 ]
Zhang, Jing-Yi [1 ]
Togn, Xiao-Yu [1 ]
Li, Bei-Bei [1 ]
Fang, Xin [1 ]
Pu, Ren-Wang [1 ]
Zhou, Yu-Jing [1 ]
Liu, Yi-Jun [1 ]
机构
[1] Dalian Med Univ, Affiliated Hosp 1, Dept Radiol, Dalian 116011, Peoples R China
关键词
hook wire; pulmonary nodules; radiation dosage; tomography; X-ray computed; ITERATIVE RECONSTRUCTION; NEEDLE-BIOPSY; CHEST CT; GUIDELINES; REDUCTION; EFFICACY; PROTOCOL;
D O I
10.3390/diagnostics13203235
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: CT-guided hook-wire localization is an essential step in the management of small pulmonary nodules. Few studies, however, have focused on reducing radiation exposure during the procedure. Purpose: This study aims to explore the feasibility of implementing a low-dose computed tomography (CT)-guided hook wire localization using tailored kVp based on patients' body size. Materials and Methods: A total of 151 patients with small pulmonary nodules were prospectively enrolled for CT-guided hook wire localization using individualized low-dose CT (LDCT) vs. standard-dose CT (SDCT) protocols. Radiation dose, image quality, characteristics of target nodules and procedure-related variables were compared. All variables were analyzed using Chi-Square and Student's t-test. Results: The mean CTDIvol was significantly reduced for LDCT (for BMI <= 21 kg/m(2), 0.56 +/- 0.00 mGy and for BMI > 21 kg/m(2), 1.48 +/- 0.00 mGy) when compared with SDCT (for BMI <= 21 kg/m(2), 5.24 +/- 0.95 mGy and for BMI > 21 kg/m(2), 6.69 +/- 1.47 mGy). Accordingly, the DLP of LDCT was significantly reduced as compared with that of SDCT (for BMI <= 21 kg/m(2), 56.86 +/- 4.73 vs. 533.58 +/- 122.06 mGy.cm, and for BMI > 21 kg/m(2), 167.02 +/- 38.76 vs. 746.01 +/- 230.91 mGy.cm). In comparison with SDCT, the effective dose (ED) of LDCT decreased by an average of 89.42% (for BMI <= 21 kg/m(2)) and 77.68% (for BMI > 21 kg/m(2)), respectively. Although the images acquired with the LDCT protocol yielded inferior quality to those acquired with the SDCT protocol, they were clinically acceptable for hook wire localization. Conclusions: LDCT-guided localization can provide safety and nodule detection performance comparable to SDCT-guided localization, benefiting radiation dose reduction dramatically, especially for patients with small body mass indexes.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Clinical Analysis of Percutaneous Computed Tomography-Guided Hook Wire Localization of 168 Small Pulmonary Nodules
    Xu, Xuanli
    Yao, Yake
    Shen, Yihong
    Zhang, Pei
    Zhou, Jianying
    ANNALS OF THORACIC SURGERY, 2015, 100 (05): : 1861 - 1867
  • [2] Preoperative computed tomography-guided soft hook-wire localization for multiple pulmonary nodules
    Li, Guang-Chao
    Wu, Zheng-Long
    Shi, Yi-Bing
    Wang, Jing-Ya
    Fu, Yu-Fei
    FRONTIERS IN ONCOLOGY, 2025, 15
  • [3] Preoperative Computed Tomography-guided Hook-wire Localisation of Pulmonary Nodules
    Ho, G.
    Wong, S. H. M.
    Cheng, L. C.
    HONG KONG JOURNAL OF RADIOLOGY, 2011, 14 (01): : 56 - 61
  • [4] Preoperative computed tomography-guided hook-wire positioning of pulmonary nodules
    Li, W.
    Zhai, C. B.
    Guan, Y. J.
    Jing, L. J.
    Zhang, Z. L.
    Zhao, X. H.
    GENETICS AND MOLECULAR RESEARCH, 2015, 14 (02) : 3798 - 3806
  • [5] Preoperative computed tomography-guided localization for pulmonary nodules: comparison between hook-wire and anchored needle localization
    Zhou, Wen-Jie
    Chen, Gang
    Huang, Ya-Yong
    Peng, Peng
    Lv, Peng-Hua
    Lv, Jing-Li
    VIDEOSURGERY AND OTHER MINIINVASIVE TECHNIQUES, 2024, 19 (01) : 91 - 99
  • [6] Efficacy and Complications of Computed Tomography-Guided Hook Wire Localization
    Ichinose, Junji
    Kohno, Tadasu
    Fujimori, Sakashi
    Harano, Takashi
    Suzuki, Souichiro
    ANNALS OF THORACIC SURGERY, 2013, 96 (04): : 1203 - 1208
  • [7] Pre-operative localization of solitary pulmonary nodules with computed tomography-guided hook wire: report of 181 patients
    Hanauer, Matthieu
    Perentes, Jean Yannis
    Krueger, Thorsten
    Ris, Hans-Beat
    Bize, Pierre
    Schmidt, Sabine
    Gonzalez, Michel
    JOURNAL OF CARDIOTHORACIC SURGERY, 2016, 11
  • [8] Pre-operative localization of solitary pulmonary nodules with computed tomography-guided hook wire: report of 181 patients
    Matthieu Hanauer
    Jean Yannis Perentes
    Thorsten Krueger
    Hans-Beat Ris
    Pierre Bize
    Sabine Schmidt
    Michel Gonzalez
    Journal of Cardiothoracic Surgery, 11
  • [9] Percutaneous computed tomography-guided localization of pulmonary nodules with hook wire prior to video-assisted thoracoscopic surgery
    Manouvelou, Stamo
    Mosa, Eftychia
    Tolia, Maria
    Tsoukalas, Nikolaos
    Nikolaou, Michail
    Nikolaou, Georgios
    Dountsis, Apostolos
    Andriotis, Efthymios
    Vasilikos, Konstantinos
    Kyrgias, George
    JOURNAL OF BUON, 2019, 24 (01): : 267 - 272
  • [10] Computed tomography-guided cyanoacrylate localization of small pulmonary nodules: feasibility and initial experience
    Yao, Fei
    Yao, Ju
    Xu, Lei
    Wang, Jian
    Gao, Libing
    Wang, Jian
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2019, 28 (03) : 387 - 393