Utilization of an Endobronchial Blocker Through a Double-Lumen Tube as Rescue for Inadequate One-Lung Ventilation

被引:1
|
作者
Tang, Jonathan E. [1 ,3 ]
Roessner, Colton T. [1 ]
Stocum, Robert D. [1 ]
Stein, Erica J. [1 ]
Essandoh, Michael K. [1 ]
D'Souza, Desmond M. [2 ]
机构
[1] Ohio State Univ, Dept Anesthesiol, Wexner Med Ctr, Columbus, OH USA
[2] Ohio State Univ, Div Thorac Surg, Wexner Med Ctr, Columbus, OH USA
[3] Ohio State Univ, Clin Dept Anesthesiol, Wexner Med Ctr, 410 10th Ave, Columbus, OH 43210 USA
关键词
thoracic surgery; airway management; one-lung ventilation; double-lumen tube; endobronchial blocker; EZ-blocker; cardiothoracic anesthesia; cardiothoracic surgery; thoracic anesthesia; BRONCHIAL BLOCKERS;
D O I
10.1177/10892532241229171
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Failure to provide one-lung ventilation can prohibit minimally invasive thoracic surgeries. Strategies for one-lung ventilation include double-lumen endotracheal tubes or endobronchial blockers, but rarely both. Inability to provide lung isolation after double-lumen endotracheal tube placement requires troubleshooting and sometimes the use of extra equipment. This case describes using a unique Y-shaped endobronchial blocker placed through a left-sided double-lumen endotracheal tube after failure to achieve lung isolation with a double-lumen endotracheal tube alone.
引用
收藏
页码:50 / 53
页数:4
相关论文
共 50 条
  • [41] Positioning the double-lumen endobronchial tube -: Reply
    Fortier, G
    Bussières, J
    Coté, D
    Bergeron, C
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2002, 49 (05): : 527 - 527
  • [42] Left mainstem bronchial rupture during one-lung ventilation with Robertshaw double lumen endobronchial tube -A case report-
    Kim, Hyun Kyu
    Jun, Joo Hwan
    Lee, Hee Sung
    Choi, Young Ryong
    Chung, Mi Hwa
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2010, 59 : S21 - S25
  • [43] One lung ventilation: double-lumen tube with vs. without carinal hook
    Potocnik, Iztok
    Andjelkovic, Lea
    Markovic-Bozic, Jasmina
    SIGNA VITAE, 2018, 14 (01) : 27 - 29
  • [44] BRONCHOSCOPIC ENDOBRONCHIAL INTUBATION WITH A SINGLE LUMEN TUBE FOR ONE-LUNG ANESTHESIA
    ELBAZ, N
    FABER, LP
    KITTLE, F
    WARREN, W
    IVANKOVICH, AD
    ANESTHESIOLOGY, 1986, 65 (3A) : A480 - A480
  • [45] An improved technique of placing a coaxial endobronchial blocker for one-lung ventilation
    Rajan, GRC
    ANESTHESIOLOGY, 2000, 93 (06) : 1563 - 1564
  • [46] The wire-guided endobronchial blocker providing one-lung ventilation
    Ng, JM
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2005, 19 (01) : 136 - 138
  • [47] Non-ventilated lung deflation during one-lung ventilation with a double-lumen endotracheal tube: a randomized-controlled trial of occluding the non-ventilated endobronchial lumen before pleural opening
    Somma, Jacques
    Couture, Etienne J.
    Pelletier, Sabrina
    Provencher, Steeve
    Moreault, Olivier
    Lohser, Jens
    Ugalde, Paula A.
    Vigneault, Louise
    Lemieux, Jerome
    Somma, Antoine
    Guay, Sarah-Elizabeth
    Bussieres, Jean S.
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2021, 68 (06): : 801 - 811
  • [48] Optimized selection of double-lumen tubes for one-lung ventilation with 3D spiral CT
    Vogel, N
    Kauczor, HU
    Heussel, C
    Mildenberger, P
    Eberle, B
    Weiler, N
    RADIOLOGY, 1996, 201 : 1277 - 1277
  • [49] The efficacy and adverse effects of the Uniblocker and left-side double-lumen tube for one-lung ventilation under the guidance of chest CT
    Liu, Zhuo
    Zhao, Li
    Zhu, Yan
    Bao, Lina
    Jia, Qian-Qian
    Yang, Xiao-Chun
    Liang, Shu-Juan
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2020, 19 (04) : 2751 - 2756
  • [50] The use of a bronchial blocker to rescue an ill-fitting double-lumen endotracheal tube
    Nino, M
    Body, SC
    Hartigan, PM
    ANESTHESIA AND ANALGESIA, 2000, 91 (06): : 1370 - 1371