Utilization of an Endobronchial Blocker Through a Double-Lumen Tube as Rescue for Inadequate One-Lung Ventilation

被引:1
|
作者
Tang, Jonathan E. [1 ,3 ]
Roessner, Colton T. [1 ]
Stocum, Robert D. [1 ]
Stein, Erica J. [1 ]
Essandoh, Michael K. [1 ]
D'Souza, Desmond M. [2 ]
机构
[1] Ohio State Univ, Dept Anesthesiol, Wexner Med Ctr, Columbus, OH USA
[2] Ohio State Univ, Div Thorac Surg, Wexner Med Ctr, Columbus, OH USA
[3] Ohio State Univ, Clin Dept Anesthesiol, Wexner Med Ctr, 410 10th Ave, Columbus, OH 43210 USA
关键词
thoracic surgery; airway management; one-lung ventilation; double-lumen tube; endobronchial blocker; EZ-blocker; cardiothoracic anesthesia; cardiothoracic surgery; thoracic anesthesia; BRONCHIAL BLOCKERS;
D O I
10.1177/10892532241229171
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Failure to provide one-lung ventilation can prohibit minimally invasive thoracic surgeries. Strategies for one-lung ventilation include double-lumen endotracheal tubes or endobronchial blockers, but rarely both. Inability to provide lung isolation after double-lumen endotracheal tube placement requires troubleshooting and sometimes the use of extra equipment. This case describes using a unique Y-shaped endobronchial blocker placed through a left-sided double-lumen endotracheal tube after failure to achieve lung isolation with a double-lumen endotracheal tube alone.
引用
收藏
页码:50 / 53
页数:4
相关论文
共 50 条
  • [31] A DOUBLE-LUMEN ENDOBRONCHIAL TUBE FOR TRACHEOSTOMIES
    BRODSKY, JB
    TOBLER, HG
    MARK, JBD
    ANESTHESIOLOGY, 1991, 74 (02) : 387 - 388
  • [32] Is there a better right-sided tube for one-lung ventilation? A comparison of the right-sided double-lumen tube with the single-lumen tube with right-sided enclosed bronchial blocker
    Campos, JH
    Massa, FC
    ANESTHESIA AND ANALGESIA, 1998, 86 (04): : 696 - 700
  • [33] Ventilation failure resulting from defective double-lumen endobronchial tube
    Irie, T
    Kurahashi, K
    Ogawa, K
    Furuya, R
    Yamada, Y
    ANESTHESIA AND ANALGESIA, 2005, 100 (06): : 1866 - 1866
  • [34] Lung separation in critically ill patients:: Is the Arndt Endobronchial Blocker® an alternative to a double-lumen endotracheal tube?
    Lischke, V
    Mierdl, S
    Westphal, K
    Meininger, D
    Byhahn, C
    ANESTHESIOLOGY, 2002, 97 (03) : B27 - B27
  • [36] A new bronchial blocker tube for one-lung ventilation
    Kraenzler, EJ
    Insler, SR
    Grubb, G
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1999, 13 (01) : 40 - 41
  • [37] Left-Sided Double-Lumen Tube vs EZ-Blocker for One-Lung Ventilation in Thoracic Surgery: A Systematic Review and Meta-Analysis
    Kumar, Nicolas
    Mitchell, Justin
    Siemens, Andrew
    Deiparine, Selina
    Saddawi-Konefka, Daniel
    Hussain, Nasir
    Iyer, Manoj H. H.
    Essandoh, Michael
    Sawyer, Tamara R. R.
    Hao, David
    SEMINARS IN CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2023, 27 (03) : 171 - 180
  • [38] One-Lung Ventilation for Lung Lobectomy Using Endobronchial Blocker Through Adjustable Silicon Hyperflex Tracheostomy Tube in Postlaryngectomy Patient
    Garg, Rakesh
    Kumari, Ambika
    Gupta, Nishkarsh
    Kumar, Vinod
    A & A CASE REPORTS, 2016, 7 (06) : 132 - 134
  • [39] Preoperative lung ultrasound for confirming the double-lumen endotracheal tube position for one-lung ventilation: A systematic review and meta-analysis
    Wang, Po-Kai
    Lin, Ting-Yu
    Su, I-Min
    Chang, Ke-Vin
    Wu, Wei-Ting
    Ozcakar, Levent
    HELIYON, 2023, 9 (04)
  • [40] A Clinical Comparison of 2 Bronchial Blockers Versus Double-Lumen Tubes for One-Lung Ventilation
    Shum, Serena
    Garijo, Jacobo Moreno
    Tomlinson, George
    Rodrigues, Jonathan
    Greyling, Gerhard
    Shafiepour, Danielle
    McRae, Karen
    Slinger, Peter
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2023, 37 (12) : 2577 - 2583