Utilization of an Endobronchial Blocker Through a Double-Lumen Tube as Rescue for Inadequate One-Lung Ventilation

被引:1
|
作者
Tang, Jonathan E. [1 ,3 ]
Roessner, Colton T. [1 ]
Stocum, Robert D. [1 ]
Stein, Erica J. [1 ]
Essandoh, Michael K. [1 ]
D'Souza, Desmond M. [2 ]
机构
[1] Ohio State Univ, Dept Anesthesiol, Wexner Med Ctr, Columbus, OH USA
[2] Ohio State Univ, Div Thorac Surg, Wexner Med Ctr, Columbus, OH USA
[3] Ohio State Univ, Clin Dept Anesthesiol, Wexner Med Ctr, 410 10th Ave, Columbus, OH 43210 USA
关键词
thoracic surgery; airway management; one-lung ventilation; double-lumen tube; endobronchial blocker; EZ-blocker; cardiothoracic anesthesia; cardiothoracic surgery; thoracic anesthesia; BRONCHIAL BLOCKERS;
D O I
10.1177/10892532241229171
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Failure to provide one-lung ventilation can prohibit minimally invasive thoracic surgeries. Strategies for one-lung ventilation include double-lumen endotracheal tubes or endobronchial blockers, but rarely both. Inability to provide lung isolation after double-lumen endotracheal tube placement requires troubleshooting and sometimes the use of extra equipment. This case describes using a unique Y-shaped endobronchial blocker placed through a left-sided double-lumen endotracheal tube after failure to achieve lung isolation with a double-lumen endotracheal tube alone.
引用
收藏
页码:50 / 53
页数:4
相关论文
共 50 条
  • [1] Comparison of double-lumen tube and bronchial blocker on one-lung ventilation for thoracoscopy
    Bauer, C
    Esclope, C
    Hentz, JG
    Ducrocq, X
    Steib, A
    Dupeyron, JP
    BRITISH JOURNAL OF ANAESTHESIA, 1999, 82 : 26 - 26
  • [2] Maintaining One-Lung Ventilation With an Endobronchial Blocker Through a Damaged Left-Sided Double-Lumen Tube: A Case Report
    Singley, Patrick M.
    Peterson, Thomas J.
    Rallya, William E.
    Iaconetti, Dominick J.
    Khandhar, Sandeep J.
    Hodgson, John A.
    A & A PRACTICE, 2022, 16 (05): : e01586
  • [3] Bronchial blocker compared to double-lumen tube for one-lung ventilation during thoracoscopy
    Bauer, C
    Winter, C
    Hentz, JG
    Ducrocq, X
    Steib, A
    Dupeyron, JP
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2001, 45 (02) : 250 - 254
  • [4] A randomized controlled study: the effect of endobronchial blocker and double-lumen endobronchial tube on one-lung ventilation in thoracic spinal tuberculosis surgery
    Niu, Zhiqiang
    Zheng, Mengliang
    Zhang, Zhijun
    Wang, Benqing
    Shan, Shiqiang
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 11 (01): : 327 - 333
  • [5] One-lung ventilation with a double-lumen tube in a thoracotomy in a dog
    Gantke, S
    KLEINTIERPRAXIS, 2000, 45 (03): : 227 - +
  • [6] The wire-guided endobronchial blocker as a solution to provide one-lung ventilation when a double-lumen endotracheal tube is malpositioned
    Kuhlman, G
    Legros, C
    Laloë, PA
    Puyo, P
    Fischler, M
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2003, 17 (05) : 636 - 637
  • [7] A Special, Modified, Double-Lumen Tube for One-Lung Ventilation in Pigs
    Schwarzkopf, Konrad
    Hueter, Lars
    Preussler, Niels-Peter
    Setzer, Florian
    Schreiber, Torsten
    Karzai, Waheedullah
    SCANDINAVIAN JOURNAL OF LABORATORY ANIMAL SCIENCE, 2010, 37 (02) : 69 - 72
  • [8] Airway injuries after one-lung ventilation: A comparison between double-lumen tube and endobronchial blocker - A randomized, prospective, controlled trial
    Knoll, Heike
    Ziegeler, Stephan
    Schreiber, Jan-Uwe
    Buchinger, Heiko
    Bialas, Patric
    Semyonov, Kirill
    Graeter, Thomas
    Mencke, Thomas
    ANESTHESIOLOGY, 2006, 105 (03) : 471 - 477
  • [9] Double-lumen endotracheal tube versus bronchial blocker in one lung ventilation
    Shan Reai
    Yuan Liuqing
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (16) : C240 - C241
  • [10] Thoracoscopic Subphrenic Pericardectomy Using Double-Lumen Endobronchial Intubation for Alternating One-Lung Ventilation
    Mayhew, Kelli N.
    Mayhew, Philipp D.
    Sorrell-Raschi, Laurie
    Brown, Dorothy Cimino