Image-guided navigation system for minimally invasive total hip arthroplasty (MITHA) using an improved position-sensing marker

被引:5
|
作者
Xie, Xianzhong [1 ]
Zhu, Mingzhu [1 ]
He, Bingwei [1 ]
Xu, Jie [2 ]
机构
[1] Fuzhou Univ, Sch Mech Engn, Fuzhou 350108, Fujian, Peoples R China
[2] Fujian Prov Hosp, Dept Orthoped Surg, Fuzhou 350013, Fujian, Peoples R China
基金
中国国家自然科学基金;
关键词
Surgery navigation; Minimally invasive total hip arthroplasty; Tracking; Point-based registration; Position-sensing marker; SURGICAL NAVIGATION; DYNAMIC NAVIGATION; POSE ESTIMATION; ACCURACY; TRACKING; REGISTRATION; PLACEMENT; TOOL;
D O I
10.1007/s11548-023-02861-x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
PurposeMinimally invasive total hip arthroplasty (MITHA) is a treatment for hip arthritis, and it causes less tissue trauma, blood loss, and recovery time. However, the limited incision makes it difficult for surgeons to perceive the instruments' location and orientation. Computer-assisted navigation systems can help improve the medical outcome of MITHA. Directly applying existing navigation systems for MITHA, however, suffers from problems of bulky fiducial marker, severe feature-loss, multiple instruments tracking confusion, and radiation exposure. To tackle these problems, we propose an image-guided navigation system for MITHA using a novel position-sensing marker.MethodsA position-sensing marker is proposed to serve as the fiducial marker with high-density and multi-fold ID tags. It results in less feature span and enables the use of ID for each feature, overcoming the problem of bulky fiducial markers and multiple instruments tracking confusion. And the marker can be recognized even when a large part of locating features is obscured. As for the elimination of intraoperative radiation exposure, we propose a point-based method to achieve patient-image registration based on anatomical landmarks.ResultsQuantitative experiments are conducted to evaluate the feasibility of our system. The accuracy of instrument positioning is achieved at 0.33 +/- 0.18 mm, and that of patient-image registration is achieved at 0.79 +/- 0.15 mm. And qualitative experiments are also performed, verifying that our system can be used in compact surgical spatial volume and can address severe feature-loss and tracking confusion problems. In addition, our system does not require any intraoperative medical scans.ConclusionExperimental results indicate that our proposed system can assist surgeons without larger space occupations, radiation exposure, and extra incision, showing its potential application value in MITHA.
引用
收藏
页码:2155 / 2166
页数:12
相关论文
共 50 条
  • [1] Image-guided navigation system for minimally invasive total hip arthroplasty (MITHA) using an improved position-sensing marker
    Xianzhong Xie
    Mingzhu Zhu
    Bingwei He
    Jie Xu
    International Journal of Computer Assisted Radiology and Surgery, 2023, 18 : 2155 - 2166
  • [2] Navigation in Minimally Invasive Total Knee Arthroplasty and Total Hip Arthroplasty
    Hafez, Mahmoud A.
    Seel, Michael J.
    Jaramaz, Branislav
    DiGioia, Anthony M., III
    OPERATIVE TECHNIQUES IN ORTHOPAEDICS, 2006, 16 (03) : 207 - 210
  • [3] Image-guided minimally invasive endopancreatic surgery using a computer-assisted navigation system
    Philip C. Müller
    Caroline Haslebacher
    Daniel C. Steinemann
    Beat P. Müller-Stich
    Thilo Hackert
    Matthias Peterhans
    Benjamin Eigl
    Surgical Endoscopy, 2021, 35 : 1610 - 1617
  • [4] Image-guided minimally invasive endopancreatic surgery using a computer-assisted navigation system
    Mueller, Philip C.
    Haslebacher, Caroline
    Steinemann, Daniel C.
    Mueller-Stich, Beat P.
    Hackert, Thilo
    Peterhans, Matthias
    Eigl, Benjamin
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2021, 35 (04): : 1610 - 1617
  • [5] Minimally Invasive Spinal Surgery with Intraoperative Image-Guided Navigation
    Kim, Terrence T.
    Johnson, J. Patrick
    Pashman, Robert
    Drazin, Doniel
    BIOMED RESEARCH INTERNATIONAL, 2016, 2016
  • [6] A New Navigation System for Minimally Invasive Total Knee Arthroplasty
    Yokoyama, Yusuke
    Abe, Nobuhiro
    Fujiwara, Kazuo
    Suzuki, Masahiko
    Nakajima, Yoshikazu
    Sugita, Naohiko
    Mitsuishi, Mamoru
    Nakashima, Yoshio
    Ozaki, Toshifumi
    ACTA MEDICA OKAYAMA, 2013, 67 (06) : 351 - 358
  • [7] Component position in 2-incision minimally invasive total hip arthroplasty compared to standard total hip arthroplasty
    Williams, Susan Lai
    Bachison, Casey
    Michelson, James D.
    Manner, Paul A.
    JOURNAL OF ARTHROPLASTY, 2008, 23 (02): : 197 - 202
  • [8] Total hip arthroplasty using the anterolateral minimally invasive approach
    Bostan, Bora
    Sen, Cengiz
    Gunes, Taner
    Erdem, Mehmet
    Aytekin, Kuersat
    Erkorkmazi, Uenal
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2009, 43 (06) : 464 - 471
  • [9] Cutting and implanting errors in minimally invasive total knee arthroplasty using a navigation system
    Hasegawa, Masahiro
    Yoshida, Kakunoshin
    Wakabayashi, Hiroki
    Sudo, Akihiro
    INTERNATIONAL ORTHOPAEDICS, 2013, 37 (01) : 27 - 30
  • [10] Cutting and implanting errors in minimally invasive total knee arthroplasty using a navigation system
    Masahiro Hasegawa
    Kakunoshin Yoshida
    Hiroki Wakabayashi
    Akihiro Sudo
    International Orthopaedics, 2013, 37 : 27 - 30