Evaluation of BACTEC MGIT 960 system for recovery of Nocardia from clinical specimens

被引:5
|
作者
Hu, Yanning [1 ,2 ,3 ]
Zhu, Yue [2 ,3 ]
Li, Chen [1 ,2 ,3 ,6 ]
Shi, Huihui [7 ]
Zhang, Yulin [2 ,3 ]
Zhao, Jiankang [2 ,3 ]
Fan, Yanyan [2 ,3 ]
Wu, Yongli [2 ,3 ,4 ]
Li, Ziyao [2 ,3 ,5 ]
Liu, Xinmeng [1 ,2 ,3 ]
Zhang, Feilong [1 ,2 ,3 ]
Lu, Binghuai [1 ,2 ,3 ,4 ,5 ]
机构
[1] Peking Univ, Hlth Sci Ctr, Peking Univ China Japan Friendship Sch Clin Med, Beijing, Peoples R China
[2] China Japan Friendship Hosp, Natl Ctr Resp Med, Dept Pulm & Crit Care Med, Lab Clin Microbiol & Infect Dis, Beijing, Peoples R China
[3] Chinese Acad Med Sci, Inst Resp Med, Beijing, Peoples R China
[4] Chinese Acad Med Sci, Peking Union Med Coll, Beijing, Peoples R China
[5] China Japan Friendship Hosp, Inst Clin Med Sci, Beijing, Peoples R China
[6] Liuyang Tradit Chinese Med Hosp, Dept Clin Lab, Changsha, Hunan, Peoples R China
[7] Shanghai Univ, Affiliated Nantong Hosp, Dept Clin Lab, Nantong, Peoples R China
关键词
Nocardia; Nocardiosis; BACTEC MGIT 960; Smear microscopy; Nocardia farcinica; SUSCEPTIBILITY;
D O I
10.1016/j.diagmicrobio.2023.115989
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Nocardia spp. is an aerobic Gram-positive bacillus responsible for nocardiosis. Herein, we performed a retro-spective study to evaluate the performance of BACTEC MGIT 960 system, in comparison with smear microscopy and blood agar plate (BAP) culture, to recover Nocardia from different clinical specimens. Furthermore, the inhibitory effect of antibiotics contained in MGIT 960 tube on Nocardia was also evaluated. The sensitivities for Nocardia recovery using smear microscopy, BAP culture, and MGIT 960 were 39.4% (54/137), 46.1% (99/215), and 81.3% (156/192), respectively. N. farcinica was the most detected species (60.4%, 136/225). In MGIT 960-recovered Nocardia strains, N. farcinica accounted for 76.9%. Furthermore, trimethoprim in MGIT 960 tube inhib-ited less N. farcinica growth than that of other Nocardia species, partially explaining why MGIT 960 recovered more N. farcinica from sputa. The current study demonstrated that MGIT 960 could recover Nocardia strains from heavily-contaminated samples if its components and antibiotics are redesigned.(c) 2023 Elsevier Inc. All rights reserved.
引用
收藏
页数:7
相关论文
共 50 条
  • [11] Evaluation of the invader assay with the BACTEC MGIT 960 system for prompt isolation and identification of mycobacterial species from clinical specimens
    Ichimura, Sadahiro
    Nagano, Makoto
    Ito, Nobuko
    Shimojima, Masahiro
    Egashira, Toru
    Miyamoto, Chikara
    Ohkusu, Kiyofumi
    Ezaki, Takayuki
    JOURNAL OF CLINICAL MICROBIOLOGY, 2007, 45 (10) : 3316 - 3322
  • [12] An evaluation of the recovery of mycobacteria from urine specimens using the automated Mycobacteria Growth Indicator Tube system (BACTEC MGIT 960)
    Chan, Douglas Su Gin
    Choy, May Yee
    Wang, Suxing
    Sng, Li-Hwei
    JOURNAL OF MEDICAL MICROBIOLOGY, 2008, 57 (10) : 1220 - 1222
  • [13] Comparison of the VersaTrek and BACTEC MGIT 960 systems for the contamination rate, time of detection and recovery of mycobacteria from clinical specimens
    Yuksel, Pelin
    Saribas, Suat
    Bagdatli, Yasar
    AFRICAN JOURNAL OF MICROBIOLOGY RESEARCH, 2011, 5 (09): : 985 - 989
  • [14] Histopathological features in the clinical specimens with tuberculosis diagnosis by BACTEC MGIT 960 culture
    Cuong, Nguyen Kim
    Thanh, Dang Van
    Luong, Dinh Van
    The, Nguyen Manh
    Thai, Truong Duc
    Tuan, Anh Tran Thi
    Ha, Doan Thu
    Dat, Vu Quoc
    JOURNAL OF CLINICAL TUBERCULOSIS AND OTHER MYCOBACTERIAL DISEASES, 2023, 33
  • [15] Comparison of the BACTEC MGIT 960 and BACTEC 460TB systems for detection of mycobacteria in clinical specimens
    Huang, TS
    Chen, CS
    Lee, SSJ
    Huang, WK
    Liu, YC
    ANNALS OF CLINICAL AND LABORATORY SCIENCE, 2001, 31 (03): : 279 - 283
  • [16] Multicenter evaluation of the fully automated Bactec MGIT 960 system and three molecular methods for the isolation and the identification of mycobacteria from clinical specimens
    Kontos, F
    Petinaki, E
    Nicolaou, S
    Gitti, Z
    Anagnostou, S
    Maniati, M
    Costopoulos, C
    Tselentis, I
    Maniatis, AN
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2003, 46 (04) : 299 - 301
  • [17] Evaluation of the Bactec MGIT 960 System in Combination with the MGIT TBc Identification Test for Detection of Mycobacterium tuberculosis Complex in Respiratory Specimens
    Lu, Po-Liang
    Yang, Yuan-Chieh
    Huang, Su Chiao
    Jenh, Yi-Shan
    Lin, Yao-Cheng
    Huang, Hsin-Hui
    Chang, Tsung Chain
    JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (06) : 2290 - 2292
  • [18] Comparison of the automated mycobacteria growth indicator tube system (BACTEC 960/MGIT) with Lowenstein-Jensen medium for recovery of mycobacteria from clinical specimens
    Lu, DS
    Heeren, B
    Dunne, WM
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2002, 118 (04) : 542 - 545
  • [19] Evaluation of the Bactec 960 automated nonradiometric system for isolation of mycobacteria from clinical specimens
    Rohner, P
    Ninet, B
    Beni, AM
    Auckenthaler, R
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2000, 19 (09) : 715 - 717
  • [20] Evaluation of the Bactec 960 Automated Nonradiometric System for Isolation of Mycobacteria from Clinical Specimens
    P. Rohner
    B. Ninet
    A.-M. Beni
    R. Auckenthaler
    European Journal of Clinical Microbiology and Infectious Diseases, 2000, 19 : 715 - 717