Enhanced pool boiling of refrigerants R-134a, R-1336mzz(Z) and R-1336mzz(E) on micro- and nanostructured tubes

被引:2
|
作者
Fu, Wuchen [1 ]
Chen, Yiyang [1 ]
Inanlu, Mohammad Jalal [1 ]
Thukral, Tarandeep Singh [1 ]
Li, Jiaqi [1 ]
Miljkovic, Nenad [1 ,2 ,3 ,4 ,5 ]
机构
[1] Univ Illinois, Dept Mech Sci & Engn, Urbana, IL 61820 USA
[2] Univ Illinois, Mat Res Lab, Urbana, IL 61820 USA
[3] Univ Illinois, Dept Elect & Comp Engn, Urbana, IL 61820 USA
[4] Univ Illinois, Inst Sustainabil Energy & Environm, Urbana, IL 61820 USA
[5] Kyushu Univ, Int Inst Carbon Neutral Energy Res WPI I2CNER, 744 Motooka,Nishi Ku, Fukuoka 8190395, Japan
关键词
Refrigerant; Bubble; Surface tension; Etching; Oxidation; Chiller; Electronics cooling; Low-GWP; Electrification; Decarbonization; HEAT-TRANSFER COEFFICIENTS; LOW-GWP REFRIGERANTS; R1233ZD(E); SURFACES; DROP;
D O I
10.1016/j.ijheatmasstransfer.2023.124983
中图分类号
O414.1 [热力学];
学科分类号
摘要
Pool boiling of refrigerants is a primary heat transfer mode in flooded evaporators, as well as a promising solution in electronics cooling applications. In this work, the pool boiling performance of R-134a, R-1336mzz(E), and R-1336mzz(Z) on the external side of round tubes are reported and compared to Cooper's heat transfer coefficient (HTC) model. Modification of Cooper's correlation is found to be necessary for R-1336mzz(Z) at low reduced pressure. Micro- and nanostructured tubes are tested using the three different refrigerants and are shown to enhance the boiling HTC. Specifically, three various structures consisting of: boehmite (AlO(OH)) nanostructures, etched aluminum microstructures, and copper oxide (CuO) micro-nanostructures are fabricated on the external sides of aluminum and copper tubes. The surface structures have characteristic length scales of 100 nm, 1 mu m, and 10 mu m for boehmite, CuO, and etched aluminum, respectively. While the boiling HTC is enhanced up to 250% (compared to smooth tubes) using R-134a with etched aluminum, it shows a 15% decrease in HTC when boehmite structures are used. For CuO, higher heat fluxes showed a 25% HTC enhancement, while lower heat fluxes showed negligible effects when compared to smooth copper tubing. Different refrigerants showed various relations between structure and HTC enhancements. To take account of both structure length scale and refrigerant properties, we introduce a normalized structure size (Rn) and conclude that HTC enhancement ratio increases non-linearly with Rn. Our study not only provides valuable data on refrigerant pool boiling of recently developed low global warming potential and ozone depleting potential fluids, it also provides valuable design guidelines for the development and application of micro- and nanostructured surfaces in chiller and electronics cooling applications.
引用
收藏
页数:22
相关论文
共 50 条
  • [31] 制冷剂R1336mzz(E)液相黏度理论与实验研究
    许晨怡
    叶恭然
    郭豪文
    庄园
    郭智恺
    韩晓红
    陈光明
    化工学报, 2021, 72 (06) : 3261 - 3269
  • [32] Pool boiling of refrigerants R-134a and R-404A on porous and structured tubes part I. Visualization of bubble dynamics
    Fan, CF
    Yang, CY
    JOURNAL OF ENHANCED HEAT TRANSFER, 2006, 13 (01) : 65 - 83
  • [33] Pool boiling of refrigerants R-134a and R-404A on porous and structured tubes part II. Heat transfer performance
    Yang, CY
    Fan, CF
    JOURNAL OF ENHANCED HEAT TRANSFER, 2006, 13 (01) : 85 - 97
  • [34] A Helmholtz Energy Equation of State for trans-1,1,1,4,4,4-Hexafluoro-2-butene [R-1336mzz(E)] and an Auxiliary Extended Corresponding States Model for the Transport Properties
    Akasaka, Ryo
    Huber, Marcia L.
    Simoni, Luke D.
    Lemmon, Eric W.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2023, 44 (04)
  • [35] A Helmholtz Energy Equation of State for trans-1,1,1,4,4,4-Hexafluoro-2-butene [R-1336mzz(E)] and an Auxiliary Extended Corresponding States Model for the Transport Properties
    Ryo Akasaka
    Marcia L. Huber
    Luke D. Simoni
    Eric W. Lemmon
    International Journal of Thermophysics, 2023, 44
  • [36] Prospect Evaluation of Low-GWP Refrigerants R1233zd(E) and R1336mzz(Z) Used in Solar-Driven Ejector-Vapor Compression Hybrid Refrigeration System
    Xuehui Wang
    Yuying Yan
    Edward Wright
    Xinyue Hao
    Neng Gao
    Journal of Thermal Science, 2021, 30 : 1572 - 1580
  • [37] Simultaneous experimental comparison of low-GWP refrigerants as drop-in replacements to R245fa for Organic Rankine cycle application: R1234ze(Z), R1233zd(E), and R1336mzz(E)
    Yang, Jingye
    Ye, Zhenhong
    Yu, Binbin
    Ouyang, Hongsheng
    Chen, Jiangping
    ENERGY, 2019, 173 : 721 - 731
  • [38] Prospect Evaluation of Low-GWP Refrigerants R1233zd(E) and R1336mzz(Z) Used in Solar-Driven Ejector-Vapor Compression Hybrid Refrigeration System
    Wang Xuehui
    Yan Yuying
    Wright, Edward
    Hao Xinyue
    Gao Neng
    JOURNAL OF THERMAL SCIENCE, 2021, 30 (05) : 1572 - 1580
  • [39] Prospect Evaluation of Low-GWP Refrigerants R1233zd(E) and R1336mzz(Z) Used in Solar-Driven Ejector-Vapor Compression Hybrid Refrigeration System
    WANG Xuehui
    YAN Yuying
    WRIGHT Edward
    HAO Xinyue
    GAO Neng
    Journal of Thermal Science, 2021, 30 (05) : 1572 - 1580
  • [40] Analysis of real gas equation of state for CFD modelling of twin screw expanders with R245fa, R290, R1336mzz(Z) and R1233zd(E)
    Rane, Sham
    Kovacevic, Ahmed
    Stosic, Nikola
    Smith, Ian
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 121 : 313 - 326