Simultaneous experimental comparison of low-GWP refrigerants as drop-in replacements to R245fa for Organic Rankine cycle application: R1234ze(Z), R1233zd(E), and R1336mzz(E)

被引:79
|
作者
Yang, Jingye [1 ]
Ye, Zhenhong [1 ]
Yu, Binbin [1 ]
Ouyang, Hongsheng [2 ]
Chen, Jiangping [1 ]
机构
[1] Shanghai Jiao Tong Univ, Inst Refrigerat & Cryogen, Shanghai 200240, Peoples R China
[2] Zhejiang Res Inst Chem Ind, State Key Lab Fluorine Greenhouse Gases Replaceme, Hangzhou, Zhejiang, Peoples R China
关键词
Organic rankine cycle; Alternatives; Low GWP; R1234ze(Z); R1233zd(E); R1336mzz(E); POWER-GENERATION; WORKING FLUIDS; ORC; PERFORMANCE; EXPANDERS;
D O I
10.1016/j.energy.2019.02.054
中图分类号
O414.1 [热力学];
学科分类号
摘要
Micro-scale organic Rankine cycle (ORC) enables to convert low-temperature waste heat into electricity, which is presented as one of combined heat and power (CHP) technologies. The commonly utilized working fluid R245fa will be phased out in the near future because of significant impact to the climate change. In that case, new HFOs (hydrofluoroolefins) refrigerants are suggested as potential alternatives to R245fa because of extremely low GWPs (Global Warming Potential) and zero ODP (Ozone Depletion Potential). This paper experimentally analyzed the applicability of three HFO refrigerants as drop-in replacements to R245fa for micro-scale ORC application including R1234ze(Z), R1233zd(E) and R1336mzz(E). Control options were assigned to the refrigerant mass flow rate and the expander rotational speed. System performance indicators including cycle thermal efficiency and net power output were compared. Besides, the expansion behavior along with the heat transfer performance and pump work were also analyzed. For the whole range of operating conditions, comparing the maximum cycle thermal efficiency, R245fa is 4.6% while R1233zd(E), R1234ze(Z) and R1336mzz(E) are 4.7%, 4.5% and 3.1%, respectively; Comparing the maximum net power output, R245fa generates 11.4% more than R1233zd(E) and 3.1% than R1234ze(Z). Limited range of pressure ratio contributes to the extremely low electricity of R1336mzz(E). (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:721 / 731
页数:11
相关论文
共 50 条
  • [1] Simulation of a scroll expander using R1233zd(E), R1234ze(Z) and their mixtures as drop-in replacements for R245fa
    Giuffrida, Antonio
    Pezzuto, Davide
    [J]. 4TH INTERNATIONAL SEMINAR ON ORC POWER SYSTEMS, 2017, 129 : 301 - 306
  • [2] Assessment of the low-GWP refrigerants R600a, R1234ze(Z) and R1233zd(E) for heat pump and organic Rankine cycle applications
    Longo, Giovanni A.
    Mancin, Simone
    Righetti, Giulia
    Zilio, Claudio
    Brown, J. Steven
    [J]. APPLIED THERMAL ENGINEERING, 2020, 167
  • [3] Experimental comparison and optimization guidance of R1233zd(E) as a drop-in replacement to R245fa for organic Rankine cycle application
    Yang, Jingye
    Sun, Ziyang
    Yu, Binbin
    Chen, Jiangping
    [J]. APPLIED THERMAL ENGINEERING, 2018, 141 : 10 - 19
  • [4] R1224yd(Z), R1233zd(E) and R1336mzz(Z) as replacements for R245fa: Experimental performance, interaction with lubricants and environmental impact
    Dawo, Fabian
    Fleischmann, Jonas
    Kaufmann, Florian
    Schifflechner, Christopher
    Eyerer, Sebastian
    Wieland, Christoph
    Spliethoff, Hartmut
    [J]. APPLIED ENERGY, 2021, 288
  • [5] Surface tension of low GWP refrigerants R1243zf, R1234ze(Z), and R1233zd(E)
    Kondou, Chieko
    Nagata, Ryuichi
    Nii, Noriko
    Koyama, Shigeru
    Higashi, Yukihiro
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2015, 53 : 80 - 89
  • [6] Condensation heat transfer and pressure drop characteristics of R134a, R1234ze(E), R245fa and R1233zd(E) in a plate heat exchanger
    Zhang, Ji
    Kaern, Martin Ryhl
    Ommen, Torben
    Elmegaard, Brian
    Haglind, Fredrik
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 128 : 136 - 149
  • [7] PVTx Properties of the R245fa/R1234ze(E) for Low-Temperature Organic Rankine Cycle
    Ge, Yinfei
    Qi, Yingxia
    Zhang, Fan
    Liu, Yefeng
    [J]. JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2021, 66 (12): : 4300 - 4308
  • [8] Boiling of the new low-GWP refrigerants R1234ze(Z) and R1233zd(E) inside a small commercial brazed plate heat exchanger
    Longo, Giovanni A.
    Mancin, Simone
    Righetti, Giulia
    Zilio, Claudio
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 104 : 376 - 385
  • [9] Analysis of real gas equation of state for CFD modelling of twin screw expanders with R245fa, R290, R1336mzz(Z) and R1233zd(E)
    Rane, Sham
    Kovacevic, Ahmed
    Stosic, Nikola
    Smith, Ian
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 121 : 313 - 326
  • [10] Chemical Stability Investigations of UltraLow GWP Refrigerants R-1336mzz(Z), R1336mzz(E), R-514A, R-1233zd(E), and R1224yd(Z) with Lubricants
    Kujak, Steve
    Sorenson, Elyse
    Leehey, Morgan Herried
    Robaczewski, Cameron
    Stellpflug, Trever
    Wang, Xudong
    [J]. ASHRAE TRANSACTIONS 2022, VOL 128, PT 2, 2022, 128 : 193 - 200