Cuffless Beat-to-Beat Blood Pressure Estimation from Photoplethysmogram Signals

被引:0
|
作者
Wuerich, Carolin [1 ]
Wiede, Christian [1 ]
Schiele, Gregor [2 ]
机构
[1] Fraunhofer IMS, Duisburg, Germany
[2] Univ Duisburg Essen, Embedded Syst, Duisburg, Germany
关键词
cuffless blood pressure; photoplethysmogram; personalized models; beat-to-beat predictions; signal processing; ResNet;
D O I
10.1109/CBMS58004.2023.00235
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
In recent years, many studies have been published on blood pressure (BP) estimation from photoplethysmogram (PPG) signals to overcome limitations of current BP devices, such as high risk of complications in invasive methods or limited accuracy, temporal resolution and comfort for cuff-based systems. However, most of these studies suffer from methodological drawbacks regarding data handling, leading to overly positive evaluation of such methods. We present an approach on beat-to-beat blood pressure estimation from raw PPG signals that is evaluated extensively on data of unseen test subjects. The proposed method obtains an mean absolute error +/- standard deviation of 8.07 +/- 6.86 mmHg for DBP and 8.73 +/- 7.36 mmHg for SBP. To increase transparency of the model's decision-making, we examine layer activation of the employed convolutional neural network. Moreover, we analyze the impact of fine tuning for personalization of the model and derive strategies to enhance the personalization process.
引用
收藏
页码:305 / 310
页数:6
相关论文
共 50 条
  • [31] Blood pressure measurements in research: suitability of auscultatory, beat-to-beat, and ambulatory blood pressure measurements
    Carlson, Debra J.
    Dieberg, Gudrun
    Mcfarlane, James R.
    Smart, Neil A.
    [J]. BLOOD PRESSURE MONITORING, 2019, 24 (01) : 18 - 23
  • [32] Deep Learning Model with Individualized Fine-tuning for Dynamic and Beat-to-Beat Blood Pressure Estimation
    Hong, Jingyuan
    Gao, Jiasheng
    Liu, Qing
    Zhang, Yuanting
    Zheng, Yali
    [J]. 2021 IEEE 17TH INTERNATIONAL CONFERENCE ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS (BSN), 2021,
  • [33] A Wireless Wearable Sensor Patch for the Real-Time Estimation of Continuous Beat-to-Beat Blood Pressure
    Qiu, Chunkai
    Wu, Taiyang
    Redoute, Jean-Michel
    Yuce, Mehmet Rasit
    [J]. 2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 6842 - 6845
  • [34] ESTIMATION OF BEAT-TO-BEAT STROKE VOLUME FROM PULMONARY ARTERIAL-PRESSURE CONTOUR IN MAN
    DELOSKEY, AF
    NICHOLS, WW
    CONTI, CR
    PEPINE, CJ
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1978, 16 (06) : 707 - 714
  • [35] THE ASSESSMENT OF AUTONOMIC FUNCTION FROM THE BEAT-TO-BEAT BLOOD-PRESSURE RESPONSE TO A VALSALVA MANEUVER
    FREEMAN, R
    HARRY, J
    BROADBRIDGE, C
    [J]. NEUROLOGY, 1994, 44 (04) : A221 - A221
  • [36] BEAT-TO-BEAT ESTIMATION OF PERIPHERAL RESISTANCE AND ARTERIAL COMPLIANCE DURING PRESSURE TRANSIENTS
    TOOROP, GP
    WESTERHOF, N
    ELZINGA, G
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1987, 252 (06): : H1275 - H1283
  • [37] Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure
    Payne, RA
    Symeonides, CN
    Webb, DJ
    Maxwell, SRJ
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2006, 100 (01) : 136 - 141
  • [38] SLEEP QUALITY AND CONTINUOUS, NONINVASIVE BEAT-TO-BEAT BLOOD-PRESSURE RECORDING
    VANDEBORNE, P
    NGUYEN, H
    LINKOWSKI, P
    DEGAUTE, JP
    [J]. JOURNAL OF HYPERTENSION, 1993, 11 (12) : 1423 - 1427
  • [39] Progression of Beat-to-Beat Blood Pressure Variability Despite Best Medical Management
    Webb, Alastair J. S.
    Lawson, Amy
    Wartolowska, Karolina
    Mazzucco, Sara
    Rothwell, Peter M.
    [J]. HYPERTENSION, 2021, 77 (01) : 193 - 201
  • [40] Non-invasive beat-to-beat blood pressure monitoring: new developments
    Parati, G
    Ongaro, G
    Bilo, G
    Glavina, F
    Castiglioni, P
    Di Rienzo, M
    Mancia, G
    [J]. BLOOD PRESSURE MONITORING, 2003, 8 (01) : 31 - 36