Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure

被引:280
|
作者
Payne, RA [1 ]
Symeonides, CN [1 ]
Webb, DJ [1 ]
Maxwell, SRJ [1 ]
机构
[1] Univ Edinburgh, Western Gen Hosp, Clin Pharmacol Unit, Edinburgh EH4 2XU, Midlothian, Scotland
关键词
preejection period; pulse-wave transit time;
D O I
10.1152/japplphysiol.00657.2005
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The arterial pulse-wave transit time can be measured between the ECG R-wave and the finger pulse (rPTT), and has been shown previously to have a linear correlation with blood pressure ( BP). We hypothesized that the relationship between rPTT, preejection period ( PEP; the R-wave/ mechanical cardiac delay), and BP would vary with different vasoactive drugs. Twelve healthy men ( mean age 22 yr) were studied. Beat-to-beat measurements were made of rPTT ( using ECG and photoplethysmograph finger probe), intra-arterial radial pressure, PEP ( using cardiac bioimpedance), and transit time minus PEP (pPTT). Four drugs ( glyceryl trinitrate, angiotensin II, norepinephrine, salbutamol) were administered intravenously over 15 min, with stepped dosage increase every 5 min and a 25- min saline washout between agents. All subjects in all conditions had a negative linear correlation ( R-2 = 0.39) between rPTT and systolic BP (SBP), generally constant between different drugs, apart from four subjects who had a positive rPTT/SBP correlation with salbutamol. The 95% limits of agreement between measured and rPTT-predicted SBP were +/- 17.0 mmHg. Beat-to-beat variability of rPTT showed better coherence with SBP variability than it did with heart rate variability ( P < 0.001). PEP accounted for a substantial and variable proportion of rPTT ( 12-35%). Diastolic ( DBP) and mean arterial BP ( MAP) correlated poorly with rPTT ( R-2 = 0.02 and 0.08, respectively) but better with pPTT ( rPTT corrected for PEP, R-2 = 0.41 and 0.45, respectively). The 95% limits of agreement between measured and pPTT-predicted DBP were +/- 17.3 mmHg. In conclusion, the negative correlation between rPTT and SBP is generally constant, even with marked hemodynamic perturbations. However, the relationship is not reliable enough for rPTT to be used as a surrogate marker of SBP, although it may be useful in assessing BP variability. DBP and MAP cannot be predicted from rPTT without correction for PEP. The significant contribution of PEP to rPTT means that rPTT should not be used as a marker of purely vascular function.
引用
收藏
页码:136 / 141
页数:6
相关论文
共 50 条
  • [1] Pulse transit time measured from the ECG as a marker of beat-to-beat blood pressure
    Payne, RA
    Symeonide, CN
    Maxwell, SJM
    Webb, DJ
    [J]. BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 2004, 57 (05) : 691 - 691
  • [2] The beat-to-beat relationship between pulse transit time and systolic blood pressure
    Poon, Carmen C. Y.
    Zhang, Yuan-Ting
    Wong, George
    Poon, Wai Sang
    [J]. 2008 INTERNATIONAL SPECIAL TOPIC CONFERENCE ON INFORMATION TECHNOLOGY AND APPLICATIONS IN BIOMEDICINE, VOLS 1 AND 2, 2008, : 357 - +
  • [3] Pulse transit time-estimated blood pressure: a comparison of beat-to-beat and intermittent measurement
    Hoshide, Satoshi
    Yoshihisa, Akiomi
    Tsuchida, Fumihiro
    Mizuno, Hiroyuki
    Teragawa, Hiroki
    Kasai, Takatoshi
    Koito, Hitoshi
    Ando, Shin-ichi
    Watanabe, Yoshihiko
    Takeishi, Yasuchika
    Kario, Kazuomi
    [J]. HYPERTENSION RESEARCH, 2022, 45 (06) : 1001 - 1007
  • [4] Pulse transit time-estimated blood pressure: a comparison of beat-to-beat and intermittent measurement
    Satoshi Hoshide
    Akiomi Yoshihisa
    Fumihiro Tsuchida
    Hiroyuki Mizuno
    Hiroki Teragawa
    Takatoshi Kasai
    Hitoshi Koito
    Shin-ichi Ando
    Yoshihiko Watanabe
    Yasuchika Takeishi
    Kazuomi Kario
    [J]. Hypertension Research, 2022, 45 : 1001 - 1007
  • [5] Pulse Transit Time and Pulse Width as Potential Measure for Estimating Beat-to-Beat Systolic and Diastolic Blood Pressure
    Arza, Adriana
    Lazaro, Jesus
    Gil, Eduardo
    Laguna, Pablo
    Aguilo, Jordi
    Bailon, Raquel
    [J]. 2013 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), 2013, 40 : 887 - 890
  • [6] Unexpected sawtooth artifact in beat-to-beat pulse transit time measured from patient monitor data
    Lin, Yu-Ting
    Lo, Yu-Lun
    Lin, Chen-Yun
    Frasch, Martin G.
    Wu, Hau-Tieng
    [J]. PLOS ONE, 2019, 14 (09):
  • [7] Pulse transit time measured from the ECG as a marker of exercise blood pressure
    Payne, RA
    Symeonides, CN
    Webb, DJ
    Maxwell, SR
    [J]. JOURNAL OF HYPERTENSION, 2004, 22 : S24 - S24
  • [8] Beat-to-beat oscillations in pulse pressure
    Virtanen, R
    Jula, A
    Kuusela, T
    Airaksinen, J
    [J]. CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2004, 24 (05) : 304 - 309
  • [9] Using noninvasive adjusted pulse transit time for tracking beat-to-beat systolic blood pressure during ventricular arrhythmia
    Miao, Fen
    Zhou, Bin
    Liu, Zengding
    Wen, Bo
    Li, Ye
    Tang, Min
    [J]. HYPERTENSION RESEARCH, 2022, 45 (03) : 424 - 435
  • [10] Using noninvasive adjusted pulse transit time for tracking beat-to-beat systolic blood pressure during ventricular arrhythmia
    Fen Miao
    Bin Zhou
    Zengding Liu
    Bo Wen
    Ye Li
    Min Tang
    [J]. Hypertension Research, 2022, 45 : 424 - 435