Volar Locking Plate Fixation for Distal Radius Fractures Distal to the Watershed Line with an Intact Lunate Volar Rim

被引:0
|
作者
Cha, Soo Min [1 ,2 ]
Shin, Hyun Dae [1 ]
Kim, Seung Won [1 ]
机构
[1] Chungnam Natl Univ, Chungnam Natl Univ Hosp, Reg Rheumatoid & Degenerat Arthrit Ctr, Sch Med, Daejeon, South Korea
[2] Chungnam Natl Univ, Sch Med, Dept Orthoped Surg, 266 Munwha Ro, Daejeon, South Korea
来源
关键词
Radius; Watershed line; Lunate; Volar rim; Intra-articular fracture; Plating; FLEXOR POLLICIS LONGUS; INTRAARTICULAR FRACTURES; COMPLICATIONS; TENDON; PART;
D O I
10.1142/S2424835523500753
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: We treated distal radius fractures (DRFs) beyond the watershed line without fracture of the lunate volar rim using a volar locking plate (VLP) and report the radiological and clinical outcomes at least 3 years after surgery.Methods: In 41 consecutive patients between January 2012 and August 2017, the fragment was composed of the radial styloid process (distal to the watershed line) and the lunate volar rim was intact. We evaluated demographic factors, radiological features and radiological/clinical outcomes at the final follow-up.Results: Twenty-nine patients were followed and evaluated. The mean follow-up period was 5.7 years. The mean patient age was 52.7 years and 24 patients had intracapsular intra-articular fractures. The fracture line was present in the lunate fossa in all patients. Twenty patients were classified as Soong grade 2, and five and four patients were grades 1 and 0, respectively. No radiological parameter (volar tilt, radial inclination, step-off and ulnar variance) was significantly different between the affected and contralateral normal sides. The mean visual analogue scale pain score and Disabilities of the Arm, Shoulder and Hand score, as well as the range of movement of the wrist, were not different between the affected and contralateral normal wrists. Finally, the grip strength on the affected side was 92% of the contralateral value. Major complications, such as nonunion, malunion and tendon rupture, were absent.Conclusions: DRFs distal to the watershed line with an intact lunate volar rim are rare and easy to miss. Careful inspection of 3D-CT images is necessary to determine these injuries, and the optimal choice for proper fixation of the fragment amongst the commercial VLPs would result in satisfactory radiological and clinical outcomes.Level of Evidence: Level IV (Therapeutic)
引用
下载
收藏
页码:708 / 716
页数:9
相关论文
共 50 条
  • [41] Comparison of the Orientation Angles of Volar Locking Plate Distal Ulnar Locking Screw for Distal Radius Fractures
    Abe, Shingo
    Shimada, Toshiki
    Murase, Tsuyoshi
    Kuriyama, Kohji
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2022, 47 (04): : 389.e1 - 389.e13
  • [42] Volar neutralization plate fixation of dorsally displaced distal radius fractures
    Constantine, KJ
    Clawson, MC
    Stern, PJ
    ORTHOPEDICS, 2002, 25 (02) : 125 - 128
  • [43] Mechanical failure of the distal radius volar locking plate
    Foo, Tun-Lin
    Gan, Aaron W. T.
    Soh, Tamara
    Chew, Winston Y. C.
    JOURNAL OF ORTHOPAEDIC SURGERY, 2013, 21 (03) : 332 - 336
  • [44] Functional Outcomes in Volar-Displaced Distal Radius Fractures Patients with Marginal Rim Fragment Treated by Volar Distal Locking Plates
    Naito, Kiyohito
    Sugiyama, Yoichi
    Kinoshita, Mayuko
    Obata, Hiroyuki
    Goto, Kenji
    Nagura, Nana
    Iwase, Yoshiyuki
    Obayashi, Osamu
    Kaneko, Kazuo
    JOURNAL OF HAND AND MICROSURGERY, 2019, 11 (02) : 100 - 105
  • [45] Evaluation of the Coronal Malposition of the Volar Locking Plate in the Treatment of Distal Radius Fractures
    Usta, Emirhan
    Akpolat, Ahmet O.
    Kahraman, Ahmet N.
    Kara, Adnan
    Oc, Yunus
    Kilinc, Bekir E.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (06)
  • [46] Prospective study of distal radius fractures treated with a volar locking plate system
    Osada, Denju
    Kamei, Shuzo
    Masuzaki, Koichiro
    Takai, Morimitsu
    Kameda, Masahiro
    Tamai, Kazuya
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2008, 33A (05): : 691 - 700
  • [47] Intraarticular Distal End Radius Fractures Treated with Volar Locking Plate Variations
    Gaonkar, Nishant
    Patil, Nitin
    Kolekar, Anupam
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2023, 15 : S1030 - S1032
  • [48] Volar locking plate vs epibloc system for distal radius fractures in the elderly
    Solarino, Giuseppe
    Vicenti, Giovanni
    Abate, Antonella
    Carrozzo, Massimiliano
    Picca, Girolamo
    Colella, Antonio
    Moretti, Biagio
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 : S84 - S90
  • [49] Volar locking plate fixation versus Kirschner wire fixation in distal radius fractures: a meta-analysis
    Shao, Jin
    Kong, De-Ce
    Yang, Tie-Yi
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (08): : 16230 - +
  • [50] Flexor tendon complications in distal radius fractures treated with volar rim locking plates
    Fardellas, A.
    Vernet, P.
    Facca, S.
    Liverneaux, P.
    HAND SURGERY & REHABILITATION, 2020, 39 (06): : 511 - 515