Volar Locking Plate Fixation for Distal Radius Fractures Distal to the Watershed Line with an Intact Lunate Volar Rim

被引:0
|
作者
Cha, Soo Min [1 ,2 ]
Shin, Hyun Dae [1 ]
Kim, Seung Won [1 ]
机构
[1] Chungnam Natl Univ, Chungnam Natl Univ Hosp, Reg Rheumatoid & Degenerat Arthrit Ctr, Sch Med, Daejeon, South Korea
[2] Chungnam Natl Univ, Sch Med, Dept Orthoped Surg, 266 Munwha Ro, Daejeon, South Korea
来源
关键词
Radius; Watershed line; Lunate; Volar rim; Intra-articular fracture; Plating; FLEXOR POLLICIS LONGUS; INTRAARTICULAR FRACTURES; COMPLICATIONS; TENDON; PART;
D O I
10.1142/S2424835523500753
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: We treated distal radius fractures (DRFs) beyond the watershed line without fracture of the lunate volar rim using a volar locking plate (VLP) and report the radiological and clinical outcomes at least 3 years after surgery.Methods: In 41 consecutive patients between January 2012 and August 2017, the fragment was composed of the radial styloid process (distal to the watershed line) and the lunate volar rim was intact. We evaluated demographic factors, radiological features and radiological/clinical outcomes at the final follow-up.Results: Twenty-nine patients were followed and evaluated. The mean follow-up period was 5.7 years. The mean patient age was 52.7 years and 24 patients had intracapsular intra-articular fractures. The fracture line was present in the lunate fossa in all patients. Twenty patients were classified as Soong grade 2, and five and four patients were grades 1 and 0, respectively. No radiological parameter (volar tilt, radial inclination, step-off and ulnar variance) was significantly different between the affected and contralateral normal sides. The mean visual analogue scale pain score and Disabilities of the Arm, Shoulder and Hand score, as well as the range of movement of the wrist, were not different between the affected and contralateral normal wrists. Finally, the grip strength on the affected side was 92% of the contralateral value. Major complications, such as nonunion, malunion and tendon rupture, were absent.Conclusions: DRFs distal to the watershed line with an intact lunate volar rim are rare and easy to miss. Careful inspection of 3D-CT images is necessary to determine these injuries, and the optimal choice for proper fixation of the fragment amongst the commercial VLPs would result in satisfactory radiological and clinical outcomes.Level of Evidence: Level IV (Therapeutic)
引用
下载
收藏
页码:708 / 716
页数:9
相关论文
共 50 条
  • [21] Efficacy of volar locking plate fixation for unstable distal radius fractures in elderly patients
    Wang, Minghui
    Wang, Bin
    Wang, Xiuhui
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 11 (02): : 1185 - 1191
  • [22] What are the ideal screw lengths in volar locking plate fixation for distal radius fractures?
    Kilian, M.
    Simkovic, P.
    Zamborsky, R.
    Skoda, A.
    Labas, P.
    BRATISLAVA MEDICAL JOURNAL-BRATISLAVSKE LEKARSKE LISTY, 2019, 120 (07): : 505 - 509
  • [23] Fixation of Dorsally Displaced Distal Radius Fractures With Volar Plate
    Othman, Ahmed Y.
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2009, 66 (05): : 1416 - 1420
  • [24] Complications of Volar Plate Fixation for Managing Distal Radius Fractures
    Berglund, Lisa M.
    Messer, Terry M.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2009, 17 (06) : 369 - 377
  • [25] Predicting a Safe Screw Length for Volar Plate Fixation of Distal Radius Fractures: Lunate Depth as a Marker for Distal Radius Depth
    Ljungquist, Karin L.
    Agnew, Sonya P.
    Huang, Jerry I.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (05): : 940 - 944
  • [26] Functional Outcome of Volar Locking Plate Fixation in Distal Radius Fracture
    Raza, Shahid
    Raza, Sibtain
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2018, 12 (01): : 330 - 333
  • [27] Using Trident distal radial locking plate to fix the fracture of distal radius volar rim
    Huang, Yin-Ming
    Chen, Chun-Yu
    Lin, Kai-Cheng
    Lai, Wei-Yi
    Lin, Yi-Ying
    Fu, Yun-Ju
    Tarng, Yih-Wen
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2023, 86 (04) : 426 - 430
  • [28] Volar locking compression T-plate for distal radius fractures
    Lattmann, T
    Dietrich, M
    Meier, C
    Kilgus, M
    Platz, A
    BRITISH JOURNAL OF SURGERY, 2005, 92 (07) : 905 - 905
  • [29] Following Distal Radius Volar Plate Fixation
    Bachoura, Abdo
    Prokuski-Lund, Vanessa
    Kane, Patrick
    Zelouf, David S.
    Osterman, Lee
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2024, 49 (08): : 736 - 744
  • [30] Volar locking plate fixation versus external fixation of distal radius fractures: a meta-analysis
    Gouk, Conor J. C.
    Bindra, Randip R.
    Tarrant, Drew J.
    Thomas, Michael J. E.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2018, 43 (09) : 954 - 960