Anatomical analysis of different helical plate designs for proximal humeral shaft fracture fixation

被引:6
|
作者
Pastor, Torsten [1 ,2 ]
Kastner, Philipp [1 ,3 ]
Souleiman, Firas [1 ,4 ]
Gehweiler, Dominic [1 ]
Migliorini, Filippo [5 ]
Link, Bjorn-Christian [2 ]
Beeres, Frank J. P. [2 ]
Babst, Reto [2 ,6 ]
Nebelung, Sven [7 ]
Ganse, Bergita [8 ,9 ]
Schoeneberg, Carsten [10 ]
Gueorguiev, Boyko [1 ]
Knobe, Matthias [2 ,11 ,12 ]
机构
[1] AO Res Inst Davos, Davos, Switzerland
[2] Lucerne Cantonal Hosp, Dept Orthopaed & Trauma Surg, Luzern, Switzerland
[3] Johannes Kepler Univ Linz, Dept Orthopaed & Traumatol, Linz, Austria
[4] Univ Hosp Leipzig, Dept Orthopaed Trauma & Plast Surg, Leipzig, Germany
[5] Univ Aachen Hosp, Dept Orthopaed Trauma & Reconstruct Surg, RWTH, Aachen, Germany
[6] Univ Lucerne, Dept Hlth Sci & Med, Luzern, Switzerland
[7] Univ Hosp Aachen, Dept Diagnost & Intervent Radiol, Aachen, Germany
[8] Saarland Univ, Werner Siemens Fdn Endowed Chair Innovat Implant, Clin & Inst Surg, Homburg, Germany
[9] Saarland Univ Hosp, Dept Trauma Hand & Reconstruct Surg, Homburg, Germany
[10] Alfried Krupp Hosp, Dept Orthoped & Emergency Surg, Essen, Germany
[11] Univ Zurich, Med Fac, Zurich, Switzerland
[12] RWTH Aachen Univ Hosp, Med Fac, Aachen, Germany
关键词
Helical plating; Proximal humeral shaft fractures; ALPS; MIPO; Anatomy; OSTEOSYNTHESIS MIPO; DELTOID INSERTION; DIAPHYSEAL; PLACEMENT;
D O I
10.1007/s00068-022-02082-y
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives Helical plates are preferably used for proximal humeral shaft fracture fixation and potentially avoid radial nerve irritation. Aims Safety of applying four different long plate designs (straight, 45 degrees-, 90 degrees-helical and ALPS) with MIPO technique as well as assessment and comparison of their distances to adjacent anatomical structures. Methods MIPO was performed in 16 human cadaveric humeri using either a straight (group 1), a 45 degrees-helical (group 2), a 90 degrees-helical (group 3) plate, or an ALPS (group 4). Applying CT angiography, distances between brachial arteries and plates were evaluated. All specimens were dissected and distances to the axillary, radial and musculocutaneous nerve were evaluated. Results No specimens demonstrated injuries of the anatomical structures at risk after MIPO with all investigated plate designs. Closest overall distance (mean (range); mm) between each plate and the radial nerve was 1 (1-3) in group 1, 7 (2-11) in group 2, 14 (7-25) in group 3 and 6 (3-8) in group 4. It was significantly bigger in group 3 and significantly smaller in group 1 compared to all other groups, p < 0.001. Closest overall distance between each plate and the musculocutaneous nerve was 16 (8-28) in group 1, 11 (7-18) in group 2, 3 (2-4) in group 3 and 6 (3-8) in group 4. It was significantly bigger in group 1 and significantly smaller in group 3 compared to all other groups, p < 0.001. Conclusions MIPO with 45 degrees- and 90 degrees-helical plates as well as with ALPS is safely feasible and demonstrates significantly bigger distances to the radial nerve compared to straight plates. However, the distances remain small and attention must be paid to the musculocutaneous nerve and the brachial artery when MIPO is applied using ALPS, 45 degrees- and 90 degrees-helical implants.
引用
收藏
页码:411 / 418
页数:8
相关论文
共 50 条
  • [31] Single versus double plate fixation of humeral shaft nonunion
    Unal, Melih
    Kati, Yusuf Alper
    Acar, Baver
    Turan, Adil
    Ozturk, Serra
    Yuksel, Halil Yalcin
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (02) : 693 - 699
  • [32] Single versus double plate fixation of humeral shaft nonunion
    Melih Unal
    Yusuf Alper Katı
    Baver Acar
    Adil Turan
    Serra Ozturk
    Halil Yalçın Yuksel
    Archives of Orthopaedic and Trauma Surgery, 2024, 144 : 693 - 699
  • [33] Small-Fragment Plate Fixation of Humeral Shaft Fractures
    Langhammer, Christopher G.
    Rotunno, Giuliana
    Sebastian, Christina
    Nascone, Jason W.
    O'toole, Robert V.
    Eglseder, W. Andrew
    Sciadini, Marcus F.
    ORTHOPEDICS, 2023, 46 (04) : 198 - 204
  • [34] Humeral shaft fractures Intramedullary nail versus plate fixation
    Mohid Bhandari
    Joseph R
    Beate P.Hanson
    Dan C. Norvell
    中华创伤骨科杂志, 2004, (06) : 81 - 83
  • [35] Innovative use of Proximal Humeral Interlocking System (PHILOS) plate for fixation of osteoporotic fibula fracture
    Wronka, Ks
    Topliss, C.
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2012, 94 (06) : 441 - 441
  • [36] Treatment of complex proximal humeral fracture: plate and tension band fixation versus conservative therapy
    Sun, Yangbai
    Li, Li
    Dai, Jiezhi
    Wang, Ting
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (05): : 7143 - 7151
  • [37] Conservative treatment, plate fixation, or prosthesis for proximal humeral fracture. A prospective randomized study
    Antti P Launonen
    Vesa Lepola
    Tapio Flinkkilä
    Niko Strandberg
    Johanna Ojanperä
    Pekka Rissanen
    Antti Malmivaara
    Ville M Mattila
    Petra Elo
    Timo Viljakka
    Minna Laitinen
    BMC Musculoskeletal Disorders, 13
  • [38] Biomechanical analysis of proximal humeral fixation using locking plate fixation with an intramedullary fibular allograft
    Mathison, Craig
    Chaudhary, Rey
    Beaupre, Lauren
    Reynolds, Mathew
    Adeeb, Samer
    Bouliane, Martin
    CLINICAL BIOMECHANICS, 2010, 25 (07) : 642 - 646
  • [39] Conservative treatment, plate fixation, or prosthesis for proximal humeral fracture. A prospective randomized study
    Launonen, Antti P.
    Lepola, Vesa
    Flinkkila, Tapio
    Strandberg, Niko
    Ojanpera, Johanna
    Rissanen, Pekka
    Malmivaara, Antti
    Mattila, Ville M.
    Elo, Petra
    Viljakka, Timo
    Laitinen, Minna
    BMC MUSCULOSKELETAL DISORDERS, 2012, 13
  • [40] Reduction and fixation of proximal humeral fracture with severe medial instability using a small locking plate
    Yuelei Zhang
    Lifu Wan
    Lecheng Zhang
    Chao Yan
    Gang Wang
    BMC Surgery, 21