Anatomical analysis of different helical plate designs for proximal humeral shaft fracture fixation

被引:6
|
作者
Pastor, Torsten [1 ,2 ]
Kastner, Philipp [1 ,3 ]
Souleiman, Firas [1 ,4 ]
Gehweiler, Dominic [1 ]
Migliorini, Filippo [5 ]
Link, Bjorn-Christian [2 ]
Beeres, Frank J. P. [2 ]
Babst, Reto [2 ,6 ]
Nebelung, Sven [7 ]
Ganse, Bergita [8 ,9 ]
Schoeneberg, Carsten [10 ]
Gueorguiev, Boyko [1 ]
Knobe, Matthias [2 ,11 ,12 ]
机构
[1] AO Res Inst Davos, Davos, Switzerland
[2] Lucerne Cantonal Hosp, Dept Orthopaed & Trauma Surg, Luzern, Switzerland
[3] Johannes Kepler Univ Linz, Dept Orthopaed & Traumatol, Linz, Austria
[4] Univ Hosp Leipzig, Dept Orthopaed Trauma & Plast Surg, Leipzig, Germany
[5] Univ Aachen Hosp, Dept Orthopaed Trauma & Reconstruct Surg, RWTH, Aachen, Germany
[6] Univ Lucerne, Dept Hlth Sci & Med, Luzern, Switzerland
[7] Univ Hosp Aachen, Dept Diagnost & Intervent Radiol, Aachen, Germany
[8] Saarland Univ, Werner Siemens Fdn Endowed Chair Innovat Implant, Clin & Inst Surg, Homburg, Germany
[9] Saarland Univ Hosp, Dept Trauma Hand & Reconstruct Surg, Homburg, Germany
[10] Alfried Krupp Hosp, Dept Orthoped & Emergency Surg, Essen, Germany
[11] Univ Zurich, Med Fac, Zurich, Switzerland
[12] RWTH Aachen Univ Hosp, Med Fac, Aachen, Germany
关键词
Helical plating; Proximal humeral shaft fractures; ALPS; MIPO; Anatomy; OSTEOSYNTHESIS MIPO; DELTOID INSERTION; DIAPHYSEAL; PLACEMENT;
D O I
10.1007/s00068-022-02082-y
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives Helical plates are preferably used for proximal humeral shaft fracture fixation and potentially avoid radial nerve irritation. Aims Safety of applying four different long plate designs (straight, 45 degrees-, 90 degrees-helical and ALPS) with MIPO technique as well as assessment and comparison of their distances to adjacent anatomical structures. Methods MIPO was performed in 16 human cadaveric humeri using either a straight (group 1), a 45 degrees-helical (group 2), a 90 degrees-helical (group 3) plate, or an ALPS (group 4). Applying CT angiography, distances between brachial arteries and plates were evaluated. All specimens were dissected and distances to the axillary, radial and musculocutaneous nerve were evaluated. Results No specimens demonstrated injuries of the anatomical structures at risk after MIPO with all investigated plate designs. Closest overall distance (mean (range); mm) between each plate and the radial nerve was 1 (1-3) in group 1, 7 (2-11) in group 2, 14 (7-25) in group 3 and 6 (3-8) in group 4. It was significantly bigger in group 3 and significantly smaller in group 1 compared to all other groups, p < 0.001. Closest overall distance between each plate and the musculocutaneous nerve was 16 (8-28) in group 1, 11 (7-18) in group 2, 3 (2-4) in group 3 and 6 (3-8) in group 4. It was significantly bigger in group 1 and significantly smaller in group 3 compared to all other groups, p < 0.001. Conclusions MIPO with 45 degrees- and 90 degrees-helical plates as well as with ALPS is safely feasible and demonstrates significantly bigger distances to the radial nerve compared to straight plates. However, the distances remain small and attention must be paid to the musculocutaneous nerve and the brachial artery when MIPO is applied using ALPS, 45 degrees- and 90 degrees-helical implants.
引用
收藏
页码:411 / 418
页数:8
相关论文
共 50 条
  • [21] Locking Plate for Proximal Humeral Fracture in the Elderly Population: Serial Change of Neck Shaft Angle
    Pawaskar, Aditya C.
    Lee, Kee-Won
    Kim, Jong-Min
    Park, Jin-Woong
    Aminata, Iman W.
    Jung, Hong-Jun
    Chun, Jae-Myeung
    Jeon, In-Ho
    CLINICS IN ORTHOPEDIC SURGERY, 2012, 4 (03) : 209 - 215
  • [22] Humeral shaft fracture: a randomized controlled trial of nonoperative versus operative management (plate fixation)
    Khameneh, Seyed Mandi Hosseini
    Abbasian, Mohammad Reza
    Abrishamkarzadeh, Hashem
    Bagheri, Shahab
    Abdollahimajd, Fahimeh
    Safdari, Farshad
    Rahimi-Dehgolan, Shahram
    ORTHOPEDIC RESEARCH AND REVIEWS, 2019, 11 : 141 - 147
  • [23] Systematic plate fixation of humeral shaft fractures: anatomical and functional results in 156 cases and a review of the literature
    Paris, H
    Tropiano, P
    d'Orval, BC
    Chaudet, H
    Poitout, DG
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2000, 86 (04): : 346 - 359
  • [24] Biomechanical analysis of helical versus straight plating of proximal third humeral shaft fractures
    Pastor, Torsten
    Zderic, Ivan
    van Knegsel, Kenneth P.
    Beeres, Frank J. P.
    Migliorini, Filippo
    Babst, Reto
    Nebelung, Sven
    Ganse, Bergita
    Schoeneberg, Carsten
    Gueorguiev, Boyko
    Knobe, Matthias
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (08) : 4983 - 4991
  • [25] Biomechanical analysis of helical versus straight plating of proximal third humeral shaft fractures
    Torsten Pastor
    Ivan Zderic
    Kenneth P. van Knegsel
    Frank J. P. Beeres
    Filippo Migliorini
    Reto Babst
    Sven Nebelung
    Bergita Ganse
    Carsten Schoeneberg
    Boyko Gueorguiev
    Matthias Knobe
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 4983 - 4991
  • [26] Fixation of Proximal Third Humeral Shaft Fractures in Older Patients
    Quarcoopome, Jared
    Adam, John
    Baljer, Bence
    Nagi, Ahmed
    Eardley, Will
    McVie, James L.
    GERIATRIC ORTHOPAEDIC SURGERY & REHABILITATION, 2023, 14
  • [27] The plate fixation strategy of complex proximal humeral fractures
    Qi Sun
    Xiaoming Wu
    Lei Wang
    Ming Cai
    International Orthopaedics, 2020, 44 : 1785 - 1795
  • [28] Pediatric Distal Femur Fixation by Proximal Humeral Plate
    Abdelgawad, Amr Atef
    Kanlic, Enes M.
    JOURNAL OF KNEE SURGERY, 2013, 26 : S45 - S49
  • [29] The plate fixation strategy of complex proximal humeral fractures
    Sun, Qi
    Wu, Xiaoming
    Wang, Lei
    Cai, Ming
    INTERNATIONAL ORTHOPAEDICS, 2020, 44 (09) : 1785 - 1795
  • [30] DIFFERENT METHODS OF TREATMENT FOR FRACTURE OF THE HUMERAL SHAFT
    BRUG, E
    WESTPHAL, T
    SCHAFERS, G
    UNFALLCHIRURG, 1994, 97 (12): : 633 - 638