Subcooling effect on the optimal performance for a transcritical CO2 heat pump with cold thermal energy storage

被引:16
|
作者
Wang, Ji [1 ]
Evans, Michael [2 ]
Belusko, Martin [3 ]
Zhao, Chunrong [4 ]
Liu, Ming [1 ]
Bruno, Frank [1 ]
机构
[1] Univ South Australia, Future Ind Inst, Mawson Lakes Campus, Mawson Lakes, SA 5095, Australia
[2] Univ South Australia, UniSA STEM, Mawson Lakes Campus, Mawson Lakes, SA 5095, Australia
[3] Mondial Advisory, Malvern, SA 5061, Australia
[4] Univ Sydney, Sch Aerosp Mech & Mechatron Engn, Darlington, NSW 2006, Australia
关键词
Transcritical CO2 heat pump; Subcooling effect; Simultaneous heating and cooling; Cold thermal energy storage; CARBON-DIOXIDE; REFRIGERATION SYSTEM; TEMPERATURE; CYCLE; OPTIMIZATION; EXCHANGER; PRESSURE; EQUATION; LIQUID; PLANT;
D O I
10.1007/s00231-022-03333-9
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper studies the combined heating and cooling thermal performance of a CO2 heat pump system considering the sub-cooling effect. For such a system without cold thermal energy storage (CTES), the gas cooler outlet temperature normally needs to be controlled to match the cooling load required. However, the integration of CTES would enable the system to be operated under its optimal conditions depending on the ambient temperatures, i.e. a considerable amount of cooling capac-ity can be generated and stored for later use. A configuration of a CO(2 )heat pump integrated with CTES is described in this paper. A thermodynamic cycle and a simulation model considering the subcooling effect have been developed. The math-ematical model for the pinch point analysis has been newly validated against published experimental data with acceptable agreements. In the case study, the impacts of the subcooling temperature on the optimal combined performance under four ambient temperatures (5 degrees C, 15 degrees C, 25 degrees C, and 32 degrees C) have been studied. The highest optimal combined COP of 5.38 can be achieved when the ambient temperature is 5 degrees C. The detailed profiles of CO2 temperatures, heating and cooling loads, and the COPs when the CTES is in operation have been revealed for the first time. It is found when the ambient temperature is higher than the water inlet temperature (plus the pinch point temperature), the optimal cooling COPs can even have a surge without the subcooling effect, due to a lower sCO(2) temperature leaving the heat exchanger compared to the ambient temperature. Additionally, performance analysis for the CO2 heat pump system with or without CTES is compared, and it is concluded that all optimal heating, cooling, and combined COPs integrated with CTES surpass those without CTES.
引用
收藏
页码:1257 / 1275
页数:19
相关论文
共 50 条
  • [31] Ejector used in transcritical CO2 heat pump system
    Chen, Q. (zjuchenqi@zju.edu.cn), 1600, Materials China (63):
  • [32] Modelling the performance of a transcritical CO2 heat pump for high temperature heating (Reprinted)
    White, SD
    Yarrall, MG
    Cleland, DJ
    Hedley, RA
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2002, 25 (04): : 479 - 486
  • [33] Modeling and simulating the transcritical CO2 heat pump system
    Yang, Jun Lan
    Ma, Yi Tai
    Li, Min Xia
    Hua, Jun
    ENERGY, 2010, 35 (12) : 4812 - 4818
  • [34] Study on the performance of solar-assisted transcritical CO2 heat pump system with phase change energy storage suitable for rural houses
    Han, Zongwei
    Bai, Chenguang
    Ma, Xiao
    Li, Biao
    Hu, Honghao
    SOLAR ENERGY, 2018, 174 : 45 - 54
  • [35] The effect of storage temperature on the performance of a thermo-electric energy storage using a transcritical CO2 cycle
    Baik, Young-Jin
    Heo, Jaehyeok
    Koo, Junemo
    Kim, Minsung
    ENERGY, 2014, 75 : 204 - 215
  • [36] Thermo-Electric Energy Storage involving CO2 transcritical ground heat storage
    Ayachi, Fadhel
    Tauveron, Nicolas
    Tartiere, Thomas
    Colasson, Stephane
    Nguyen, Denis
    APPLIED THERMAL ENGINEERING, 2016, 108 : 1418 - 1428
  • [37] Performance Analysis of Coupled System of CO2 Transcritical Heat Pump and Rankine Cycle
    Wang, Hongli
    Tian, Jingrui
    Ma, Yitai
    Hou, Xiujuan
    MATERIALS PROCESSING TECHNOLOGY, PTS 1-4, 2011, 291-294 : 1860 - +
  • [38] Applying the transcritical CO2 process to a drying heat pump
    Schmidt, EL
    Klocker, K
    Flacke, N
    Steimle, F
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1998, 21 (03): : 202 - 211
  • [39] Reanalysis of characteristics of CO2 transcritical heat pump system
    CO2跨临界热泵系统特性再分析
    Li, Minxia (tjmxli@tju.edu.cn), 1600, Materials China (39): : 1252 - 1258
  • [40] Experimental Performance Study of a Transcritical CO2 Heat Pump Equipped with a Passive Ejector
    Ameur, K.
    Falsafioon, M.
    JOURNAL OF APPLIED FLUID MECHANICS, 2024, 17 (12) : 2533 - 2544