Subcooling effect on the optimal performance for a transcritical CO2 heat pump with cold thermal energy storage

被引:16
|
作者
Wang, Ji [1 ]
Evans, Michael [2 ]
Belusko, Martin [3 ]
Zhao, Chunrong [4 ]
Liu, Ming [1 ]
Bruno, Frank [1 ]
机构
[1] Univ South Australia, Future Ind Inst, Mawson Lakes Campus, Mawson Lakes, SA 5095, Australia
[2] Univ South Australia, UniSA STEM, Mawson Lakes Campus, Mawson Lakes, SA 5095, Australia
[3] Mondial Advisory, Malvern, SA 5061, Australia
[4] Univ Sydney, Sch Aerosp Mech & Mechatron Engn, Darlington, NSW 2006, Australia
关键词
Transcritical CO2 heat pump; Subcooling effect; Simultaneous heating and cooling; Cold thermal energy storage; CARBON-DIOXIDE; REFRIGERATION SYSTEM; TEMPERATURE; CYCLE; OPTIMIZATION; EXCHANGER; PRESSURE; EQUATION; LIQUID; PLANT;
D O I
10.1007/s00231-022-03333-9
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper studies the combined heating and cooling thermal performance of a CO2 heat pump system considering the sub-cooling effect. For such a system without cold thermal energy storage (CTES), the gas cooler outlet temperature normally needs to be controlled to match the cooling load required. However, the integration of CTES would enable the system to be operated under its optimal conditions depending on the ambient temperatures, i.e. a considerable amount of cooling capac-ity can be generated and stored for later use. A configuration of a CO(2 )heat pump integrated with CTES is described in this paper. A thermodynamic cycle and a simulation model considering the subcooling effect have been developed. The math-ematical model for the pinch point analysis has been newly validated against published experimental data with acceptable agreements. In the case study, the impacts of the subcooling temperature on the optimal combined performance under four ambient temperatures (5 degrees C, 15 degrees C, 25 degrees C, and 32 degrees C) have been studied. The highest optimal combined COP of 5.38 can be achieved when the ambient temperature is 5 degrees C. The detailed profiles of CO2 temperatures, heating and cooling loads, and the COPs when the CTES is in operation have been revealed for the first time. It is found when the ambient temperature is higher than the water inlet temperature (plus the pinch point temperature), the optimal cooling COPs can even have a surge without the subcooling effect, due to a lower sCO(2) temperature leaving the heat exchanger compared to the ambient temperature. Additionally, performance analysis for the CO2 heat pump system with or without CTES is compared, and it is concluded that all optimal heating, cooling, and combined COPs integrated with CTES surpass those without CTES.
引用
收藏
页码:1257 / 1275
页数:19
相关论文
共 50 条
  • [21] Optimal compressor discharge pressure and performance characteristics of transcritical CO2 heat pump for crude oil heating
    Li, Conghui
    Jiang, Peixue
    Zhu, Yinhai
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 144 : 99 - 107
  • [22] Experimental and theoretical analysis of the optimal high pressure and peak performance coefficient in transcritical CO2 heat pump
    Qin, Xiang
    Zhang, Fan
    Zhang, Dongwei
    Gao, Zhao
    Tang, Songzhen
    APPLIED THERMAL ENGINEERING, 2022, 210
  • [23] Energy and economic analysis of CO2 hydrate cold energy storage applications in transcritical CO2 refrigeration systems
    Zhang, Yumei
    Ma, Guoyuan
    Wang, Lei
    Nie, Junrui
    Cui, Tiantian
    JOURNAL OF ENERGY STORAGE, 2024, 102
  • [24] Optimal compressor discharge pressure and performance characteristics of transcritical CO2 heat pump for crude oil heating
    Li, Conghui
    Jiang, Peixue
    Zhu, Yinhai
    International Journal of Refrigeration, 2022, 144 : 99 - 107
  • [25] Performance Analysis of Supermarket Subcooling CO2 Refrigeration System Integrated With Seasonal Borehole Cold Energy Storage
    Dai, Baomin
    Meng, Chenyang
    Zhou, Xuan
    Cao, Yu
    Zhao, Ruirui
    Yang, Peifang
    Wang, Qi
    Liu, Shengchun
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2023, 44 (11): : 3039 - 3045
  • [26] Experimental study on the effect of compressor frequency on the performance of transcritical CO2 heat pump system with regenerator
    Yang, Ling-Xiao
    Wei, Xin-Li
    Zhao, Ling-Hua
    Qin, Xiang
    Zhang, Dong-Wei
    APPLIED THERMAL ENGINEERING, 2019, 150 : 1216 - 1223
  • [27] Study on performance evaluation of CO2 heat pump system integrated with thermal energy storage for space heating
    Wang, Zhihua
    Zheng, Yuxin
    Wang, Fenghao
    Song, Mengjie
    Ma, Zhenjun
    INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 1380 - 1387
  • [28] Experimental Study on the Compacts of Regenerative Heat on the Performance of the Transcritical CO2 Heat Pump System
    Zhao, Ling-Hua
    Wei, Xin-Li
    Yang, Ling-Xiao
    Qin, Xiang
    Zhang, Dong-Wei
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2020, 41 (01): : 186 - 195
  • [29] Performance Optimization and Economic Evaluation of CO2 Heat Pump Heating System Coupled with Thermal Energy Storage
    Wang, Zhihua
    Zhang, Yujia
    Wang, Fenghao
    Li, Guichen
    Xu, Kaiwen
    SUSTAINABILITY, 2021, 13 (24)
  • [30] Experimental investigation of the optimal heat rejection pressure for a transcritical CO2 heat pump water heater
    Qi, Peng-Cheng
    He, Ya-Ling
    Wang, Xiao-Lin
    Meng, Xiang-Zhao
    APPLIED THERMAL ENGINEERING, 2013, 56 (1-2) : 120 - 125