HEMOLYSIS DETECTION FOR ETHANOL MEASUREMENT IN WHOLE BLOOD SAMPLES BEFORE CENTRIFUGATION: HEMCHECK DEVICE EVALUATION

被引:0
|
作者
Zengi, Oguzhan [1 ]
Boz, Meltem [1 ]
Yesil, Beyazit Semih [1 ]
Gumus, Alper [1 ]
机构
[1] Hlth Sci Univ, Istanbul Basaksehir Cam & Sakura City Hosp, Dept Med Biochem, Olimpiyat Yolu Basaksehir, Istanbul, Turkiye
关键词
hemolysis; pre-analytical phase; ethanol; point-of-care testing; quality improvement; SPECIMENS; ASSAY;
D O I
10.5937/jomb0-41574
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Background: As previously reported, the measurement of ethanol can also be affected by interference from hemolysis. This is a matter of concern since ethanol is widely regarded as the most commonly abused substance globally. When sample re-collection is ordered to eliminate hemolysis effects for ethanol testing, this can have unfavourable consequences for these patients. Rapid detection of hemolysed specimens would alleviate some issues associated with forensic samples. This study aimed to assess the qualitative analytical performance of a novel point-of-care testing device per the guidelines specified in CLSI-EP-12A document. HemCheckT" is a novel POCT device that qualitatively detects free-hemoglobin levels on the specimen shortly after drawing the sample.Methods: The system consists of two components. One is a cartridge with a needle that is used to transfer a small volume of whole blood from a vacuum tube to vertical and lateral flow filtration. The second component is the reader. The consumable cartridges are designed to be inserted into the reader without requiring the syringe or blood collection tube removal. A red indicator led illuminates, indicating that the sample has been hemolysed. To assess the imprecision of the method, we determined the C5-C95 interval and C50, using the Roche Cobas clinical chemistry analyser as the comparator. For this study, we utilised residual samples.Results: Our C50 concentrations were 45 mg/dL, the C5- C95 30 mg/dL and 60 mg/dL, respectively. Two methods reveal an overall agreement of 89.2%. The diagnostic sensitivity and specificity of the study showed a positive agree-ment of 95.7% and a negative agreement of 80.0%. The calculated Cohens Kappa value was 77.3%.Conclusion: According to current literature, a bias in ethanol levels can be noticed even with small free hemo-globin concentrations. When it came to forensic samples, this bias was crucial. Our study confirmed that the HemCheck device has acceptable analytical performance, as outlined in the CLSI-EP-12A document. Although the possible beneficial impacts of the innovative POCT hemol-ysis detection device on the preanalytical phase are pro-posed, we have not studied them in this study.
引用
收藏
页码:600 / 606
页数:7
相关论文
共 50 条
  • [41] Measurement of creatinine in whole blood samples supplemented to achieve increased creatinine concentrations
    D'Orazio, Paul
    Conant, Joann
    Cervera, Jose
    CLINICAL CHEMISTRY, 2008, 54 (02) : 451 - 452
  • [42] MEASUREMENT OF NEUTROPHIL PHAGOCYTOSIS IN WHOLE-BLOOD SAMPLES BY FLOW-CYTOMETRY
    ZHANG, P
    SPITZER, JA
    FASEB JOURNAL, 1993, 7 (03): : A364 - A364
  • [43] Clinical evaluation of the first medical whole blood, point-of-care testing device for detection of myocardial infarction
    Apple, FS
    Anderson, FP
    Collinson, P
    Jesse, RL
    Kontos, MC
    Levitt, MA
    Miller, EA
    Murakami, MM
    CLINICAL CHEMISTRY, 2000, 46 (10) : 1604 - 1609
  • [44] DEVELOPMENT OF A SIMPLE DEVICE FOR PROCESSING WHOLE-BLOOD SAMPLES INTO MEASURED ALIQUOTS OF PLASMA
    BURTIS, CA
    JOHNSON, WF
    WALKER, WA
    CLINICAL CHEMISTRY, 1986, 32 (09) : 1642 - 1647
  • [45] EVALUATION OF A METHOD FOR MEASUREMENT OF CYCLOSPORINE IN WHOLE-BLOOD BY HPLC
    BINDER, SR
    KEENAN, D
    REGALIA, MJ
    BIAGGI, M
    CLINICAL BIOCHEMISTRY, 1987, 20 (04) : 299 - 299
  • [46] Novel point of care testing device for rapid measurement of clozapine in whole blood
    Sumanth, A.
    Kozo, D.
    Courtney, J.
    Siegfried, N.
    Gill, R.
    Hilaire, M. R.
    Venkateswaran, A.
    Harney, R.
    Jarrah, J.
    Distefano, K.
    Salamone, S.
    Baburina, I.
    CLINICA CHIMICA ACTA, 2019, 493 : S767 - S768
  • [47] Evaluation of a new venous catheter blood draw device and its impact on specimen hemolysis rates
    Natali, Ruth
    Wand, Cara
    Doyle, Kelly
    Noguez, Jaime H.
    PRACTICAL LABORATORY MEDICINE, 2018, 10 : 38 - 43
  • [48] ENZYME-COUPLED MEASUREMENT OF ETHANOL IN WHOLE-BLOOD AND PLASMA WITH A CENTRIFUGAL ANALYZER
    JUNG, G
    FERARD, G
    CLINICAL CHEMISTRY, 1978, 24 (06) : 873 - 876
  • [49] EVALUATION OF A DIGITAL DEVICE FOR HOME BLOOD-PRESSURE MEASUREMENT
    BURRIS, JF
    PHILLIPS, M
    CLINICAL RESEARCH, 1982, 30 (02): : A638 - A638
  • [50] Evaluation of the human immunodeficiency virus type 1 and 2 antibodies detection in dried whole blood spots (DBS) samples
    de Castro, Andrea Cauduro
    dos Anjos Borges, Luiz Gustavo
    de Souza, Ricardo da Silva
    Grudzinski, Melina
    D'Azevedo, Pedro Alves
    REVISTA DO INSTITUTO DE MEDICINA TROPICAL DE SAO PAULO, 2008, 50 (03): : 151 - 156