HEMOLYSIS DETECTION FOR ETHANOL MEASUREMENT IN WHOLE BLOOD SAMPLES BEFORE CENTRIFUGATION: HEMCHECK DEVICE EVALUATION

被引:0
|
作者
Zengi, Oguzhan [1 ]
Boz, Meltem [1 ]
Yesil, Beyazit Semih [1 ]
Gumus, Alper [1 ]
机构
[1] Hlth Sci Univ, Istanbul Basaksehir Cam & Sakura City Hosp, Dept Med Biochem, Olimpiyat Yolu Basaksehir, Istanbul, Turkiye
关键词
hemolysis; pre-analytical phase; ethanol; point-of-care testing; quality improvement; SPECIMENS; ASSAY;
D O I
10.5937/jomb0-41574
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Background: As previously reported, the measurement of ethanol can also be affected by interference from hemolysis. This is a matter of concern since ethanol is widely regarded as the most commonly abused substance globally. When sample re-collection is ordered to eliminate hemolysis effects for ethanol testing, this can have unfavourable consequences for these patients. Rapid detection of hemolysed specimens would alleviate some issues associated with forensic samples. This study aimed to assess the qualitative analytical performance of a novel point-of-care testing device per the guidelines specified in CLSI-EP-12A document. HemCheckT" is a novel POCT device that qualitatively detects free-hemoglobin levels on the specimen shortly after drawing the sample.Methods: The system consists of two components. One is a cartridge with a needle that is used to transfer a small volume of whole blood from a vacuum tube to vertical and lateral flow filtration. The second component is the reader. The consumable cartridges are designed to be inserted into the reader without requiring the syringe or blood collection tube removal. A red indicator led illuminates, indicating that the sample has been hemolysed. To assess the imprecision of the method, we determined the C5-C95 interval and C50, using the Roche Cobas clinical chemistry analyser as the comparator. For this study, we utilised residual samples.Results: Our C50 concentrations were 45 mg/dL, the C5- C95 30 mg/dL and 60 mg/dL, respectively. Two methods reveal an overall agreement of 89.2%. The diagnostic sensitivity and specificity of the study showed a positive agree-ment of 95.7% and a negative agreement of 80.0%. The calculated Cohens Kappa value was 77.3%.Conclusion: According to current literature, a bias in ethanol levels can be noticed even with small free hemo-globin concentrations. When it came to forensic samples, this bias was crucial. Our study confirmed that the HemCheck device has acceptable analytical performance, as outlined in the CLSI-EP-12A document. Although the possible beneficial impacts of the innovative POCT hemol-ysis detection device on the preanalytical phase are pro-posed, we have not studied them in this study.
引用
收藏
页码:600 / 606
页数:7
相关论文
共 50 条
  • [31] The Measurement of Hemoglobin A2 and F in Stored Whole Blood Samples
    Mercadanti, Mariella
    Romero, Araelsis
    Lippi, Giuseppe
    CLINICAL LABORATORY, 2011, 57 (9-10) : 777 - 780
  • [32] RAPID MEASUREMENT OF THE OXYGEN SATURATION OF WHOLE BLOOD SAMPLES WITH THE MILLIKAN OXIMETER
    WATKINS, E
    PROCEEDINGS OF THE SOCIETY FOR EXPERIMENTAL BIOLOGY AND MEDICINE, 1949, 72 (01): : 180 - 184
  • [33] Disposable filtration device for plasma separation from whole blood clinical samples
    Fomovska, GN
    Seeley, K
    CLINICAL CHEMISTRY, 2005, 51 : A205 - A206
  • [34] Quantitation of Tacrolimus in Human Whole Blood Samples Using the MITRA Microsampling Device
    Undre, Nasrullah
    Hussain, Imran
    Meijer, John
    Stanta, Johannes
    Swan, Gordon
    Dawson, Ian
    THERAPEUTIC DRUG MONITORING, 2021, 43 (03) : 364 - 370
  • [35] Evaluation of a new intraoperative suction and whole blood autotransfusion device
    Kevy, SW
    Jacobson, MS
    Brustowicz, RM
    ANESTHESIOLOGY, 1998, 89 (3A) : U431 - U431
  • [36] Effect of Temperature and Preservative on Neo-ethanol Formation in Postmortem Whole Blood Samples
    Ahmad, Shakeel
    Aamir, Muhammad
    Kirmani, Sobia Irum
    Haroon, Zujaja Hina
    Bibi, Afshan
    Bin Khalid, Usama
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2021, 31 (10): : 1159 - 1162
  • [37] Detection of Babesia RNA and DNA in whole blood samples from US blood donations
    Stanley, Jean
    Stramer, Susan L.
    Erickson, Yasuko
    Cruz, Julie
    Gorlin, Jed
    Janzen, Mark
    Rossmann, Susan N.
    Straus, Todd
    Albrecht, Patrick
    Pate, Lisa Lee
    Galel, Susan A.
    TRANSFUSION, 2021, 61 (10) : 2969 - 2980
  • [38] Evaluation of a handheld device for the measurement of beta-hydroxybutyrate in capillary blood obtained by the puncture of the vulva as well as in venous whole blood in cattle
    Khol, J. L.
    Freigassner, K.
    Stanitznig, A.
    Tichy, A.
    Wittek, T.
    POLISH JOURNAL OF VETERINARY SCIENCES, 2019, 22 (03): : 557 - 564
  • [39] Measurement and Comparison of Organic Compound Concentrations in Plasma, Whole Blood, and Dried Blood Spot Samples
    Batterman, Stuart A.
    Chernyak, Sergey
    Su, Feng-Chiao
    FRONTIERS IN GENETICS, 2016, 7
  • [40] EVALUATION OF A MICRODIFFUSION METHOD FOR SEMIQUANTITATIVE MEASUREMENT OF ETHANOL IN BLOOD AND URINE
    BACHAND, SS
    MARTEL, PA
    ODONNELL, CM
    CLINICAL CHEMISTRY, 1986, 32 (06) : 1050 - 1050